Real-Time GPU-Based Ultrasound Simulation Using Deformable Mesh Models

被引:60
作者
Buerger, Benny [1 ]
Bettinghausen, Sascha [2 ]
Raedle, Matthias [2 ]
Hesser, Juergen [1 ]
机构
[1] Heidelberg Univ, Univ Med Mannheim, D-68167 Mannheim, Germany
[2] Mannheim Univ Appl Sci, Inst Proc Control & Innovat Energy Convers, D-68167 Mannheim, Germany
关键词
Graphics processing unit (GPU); medical image simulation; ray-tracing; sonography training; ultrasound image simulation;
D O I
10.1109/TMI.2012.2234474
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents a real-time capable graphics processing unit (GPU)-based ultrasound simulator suitable for medical education. The main focus of the simulator is to synthesize realistic looking ultrasound images in real-time including artifacts, which are essential for the interpretation of this data. The simulation is based on a convolution-enhanced ray-tracing approach and uses a deformable mesh model. Deformations of the mesh model are calculated using the PhysX engine. Our method advances the state of the art for real-time capable ultrasound simulators by following the path of the ultrasound pulse, which enables better simulation of ultrasound-specific artifacts. An evaluation of our proposed method in comparison with recent generative slicing-based strategies as well as real ultrasound images is performed. Hereby, a gelatin ultrasound phantom containing syringes filled with different media is scanned with a real transducer. The obtained images are then compared to images which are simulated using a slicing-based technique and our proposed method. The particular benefit of our method is the accurate simulation of ultrasound-specific artifacts, like range distortion, refraction and acoustic shadowing. Several test scenarios are evaluated regarding simulation time, to show the performance and the bottleneck of our method. While being computationally more intensive than slicing techniques, our simulator is able to produce high-quality images in real-time, tracing over 5000 rays through mesh models with more than 2 000 000 triangles of which up to 200 000 may be deformed each frame.
引用
收藏
页码:609 / 618
页数:10
相关论文
共 33 条
[1]   Real-time ultrasound imaging simulation [J].
Aiger, D ;
Cohen-Or, D .
REAL-TIME IMAGING, 1998, 4 (04) :263-274
[2]   ULTRASONIC B-SCANNING - A COMPUTER-SIMULATION [J].
BAMBER, JC ;
DICKINSON, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (03) :463-479
[3]   AN EASILY MADE, LOW-COST, TISSUE-LIKE ULTRASOUND PHANTOM MATERIAL [J].
BUDE, RO ;
ADLER, RS .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (04) :271-273
[4]  
Bürger B, 2008, STUD HEALTH TECHNOL, V132, P56
[5]   Towards a realistic echographic simulator [J].
d'Aulignac, D ;
Laugier, C ;
Troccaz, J ;
Vieira, S .
MEDICAL IMAGE ANALYSIS, 2006, 10 (01) :71-81
[6]   Fast simulation of ultrasound images from a CT volume [J].
Dillenseger, Jean-Louis ;
Laguitton, Soizic ;
Delabrousse, Eric .
COMPUTERS IN BIOLOGY AND MEDICINE, 2009, 39 (02) :180-186
[7]   A system-based approach to modeling the ultrasound signal backscattered by red blood cells [J].
Fontaine, I ;
Bertrand, M ;
Cloutier, G .
BIOPHYSICAL JOURNAL, 1999, 77 (05) :2387-2399
[8]   A Fast Convolution-Based Methodology to Simulate 2-D/3-D Cardiac Ultrasound Images [J].
Gao, Hang ;
Choi, Hon Fai ;
Claus, Piet ;
Boonen, Steven ;
Jaecques, Siegfried ;
van Lenthe, G. Harry ;
Van der Perre, Georges ;
Lauriks, Walter ;
D'hooge, Jan .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) :404-409
[9]  
Gibson S., 1997, SURVEY DEFORMABLE MO, V19
[10]   B-Mode Ultrasound Image Simulation in Deformable 3-D Medium [J].
Goksel, Orcun ;
Salcudean, Septimiu E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1657-1669