In-beam PET measurements of β+ radioactivity induced by proton beams

被引:216
|
作者
Parodi, K
Enghardt, W
Haberer, T
机构
[1] Rossendorf Inc, Forschungszentrum Rossendorf EV, D-01314 Dresden, Germany
[2] Gesell Schwerionenforsch mbH, D-64291 Darmstadt, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 01期
关键词
D O I
10.1088/0031-9155/47/1/302
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our first in-beam PET measurements of the beta(+) activation induced by proton irradiation are presented. Monoenergetic proton beams in the energy and intensity range suited for the treatment of deep-seated tumours were delivered by the synchrotron of the Gesellschaft fur Schwerionenforschung Darmstadt (GSI). They were stopped in PMMA blocks placed in the centre of the field of view of the positron camera that is installed in the heavy ion tumour treatment facility at GSI The beta(+) activity signal was found to be three times larger than that produced by carbon ions at the same range and applied physical close. The reconstructed spatial beta(+) activity, distributions were analysed and compared with the production of positron emitters predicted by a calculation based on experimental cross-sections and on the proton flux given by the FLUKA Monte Carlo code. The shape of the depth-activity profiles was well reproduced by the model and the correlation with the proton range and the depth-close distributions was carefully investigated. Despite the non-trivial range determination from the beta(+) activity distribution in the proton case, our experimental investigation supports the feasibility of an in situ proton therapy monitoring by means of in-beam PET. as already clinically implemented for the monitoring of carbon ion therapy at GSI Darmstadt.
引用
收藏
页码:21 / 36
页数:16
相关论文
共 50 条
  • [31] Full in-beam PET measurements of 62 MeV protons onto a PMMA target
    Sportelli, G.
    Straub, K.
    Aiello, M.
    Attanasi, F.
    Belcari, N.
    Camarlinghi, N.
    Cirrone, G. A. P.
    Cuttone, G.
    Ferretti, S.
    Marino, N.
    Nicolosi, D.
    Romano, F.
    Rosso, V.
    Del Guerra, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 151 - 153
  • [32] IN-BEAM MEASUREMENTS OF NUCLEAR MOMENTS
    MAHNKE, HE
    HYPERFINE INTERACTIONS, 1987, 34 (1-4): : 47 - 59
  • [33] In-Beam PET Imaging with Depth-Of-Interaction Measurement for Accurate Proton Beam-Range Verification
    Shao, Y.
    Sun, X.
    Lou, K.
    Zhu, X.
    Mirkovic, D.
    Poenisch, F.
    Grosshans, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [34] In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study
    Shao, Yiping
    Sun, Xishan
    Lou, Kai
    Zhu, Xiaorong R.
    Mirkovic, Dragon
    Poenisch, Falk
    Grosshans, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13): : 3373 - 3388
  • [35] The feasibility of in-beam PET for accurate monitoring of proton therapy:: Results of a comprehensive experimental study
    Parodi, K
    Pönisch, F
    Enghardt, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2160 - 2164
  • [36] Proton therapy treatment monitoring with in-beam PET: Investigating space and time activity distributions
    Brombal, L.
    Barbosa, D.
    Belcari, N.
    Bisogni, M. G.
    Camarlinghi, N.
    Cristoforetti, L.
    Del Guerra, A.
    Fracchiolla, F.
    Morrocchi, M.
    Sportelli, G.
    Righetto, R.
    Schwarz, M.
    Topi, A.
    Rosso, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 861 : 71 - 76
  • [37] Monte Carlo simulations for in-beam PET
    Solevi, P.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 97 - 100
  • [38] Dosimetry by Means of In-Beam PET with RI Beam Irradiation
    Nakajima, Yasunori
    Hirano, Yoshiyuki
    Tashima, Hideaki
    Yoshida, Eiji
    Sato, Shinji
    Lnaniwa, Taku
    Kohno, Toshiyuki
    Sihver, Lembit
    Yamaya, Taiga
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [39] In-Beam PET Measurements of Washout in Rabbit Using 10C, 11C and 15O Ion Beams
    Toramatsu, Chie
    Yoshida, Eiji
    Wakizaka, Hidekazu
    Mohammadi, Akram
    Tashima, Hideaki
    Nishikido, Fumihiko
    Kitagawa, Atsuchi
    Inaniwa, Taku
    Karasawa, Kumiko
    Yamaya, Taiga
    MEDICAL PHYSICS, 2017, 44 (06) : 3250 - 3251
  • [40] The use of EXOGAM for in-beam spectroscopy of proton drip-line nuclei with radioactive ion beams
    Petri, M.
    Paul, E. S.
    Nolan, P. J.
    Boston, A. J.
    Boston, H. C.
    Cooper, R. J.
    Dimmock, M. R.
    Gros, S.
    McGuirk, B. M.
    Turk, G.
    Guinet, D.
    Lautesse, Ph.
    Meyer, M.
    Redon, N.
    Rosse, B.
    Schmitt, Ch.
    Stezowski, O.
    Bhattacharyya, S.
    De France, G.
    Mukherjee, G.
    Rejmund, F.
    Savajols, H.
    Scheurer, J. N.
    Gal, J.
    Molnar, J.
    Nyako, B. M.
    Timar, J.
    Zolnai, L.
    Juhasz, K.
    Astier, A.
    Deloncle, I.
    Porquet, M. G.
    Prevost, A.
    Pucknell, V. F. E.
    Wadsworth, R.
    Joshi, P.
    La Rana, G.
    Moro, R.
    Trotta, M.
    Vardaci, E.
    Hackman, G.
    Ball, G. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (02): : 412 - 420