In-beam PET measurements of β+ radioactivity induced by proton beams

被引:216
|
作者
Parodi, K
Enghardt, W
Haberer, T
机构
[1] Rossendorf Inc, Forschungszentrum Rossendorf EV, D-01314 Dresden, Germany
[2] Gesell Schwerionenforsch mbH, D-64291 Darmstadt, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 01期
关键词
D O I
10.1088/0031-9155/47/1/302
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our first in-beam PET measurements of the beta(+) activation induced by proton irradiation are presented. Monoenergetic proton beams in the energy and intensity range suited for the treatment of deep-seated tumours were delivered by the synchrotron of the Gesellschaft fur Schwerionenforschung Darmstadt (GSI). They were stopped in PMMA blocks placed in the centre of the field of view of the positron camera that is installed in the heavy ion tumour treatment facility at GSI The beta(+) activity signal was found to be three times larger than that produced by carbon ions at the same range and applied physical close. The reconstructed spatial beta(+) activity, distributions were analysed and compared with the production of positron emitters predicted by a calculation based on experimental cross-sections and on the proton flux given by the FLUKA Monte Carlo code. The shape of the depth-activity profiles was well reproduced by the model and the correlation with the proton range and the depth-close distributions was carefully investigated. Despite the non-trivial range determination from the beta(+) activity distribution in the proton case, our experimental investigation supports the feasibility of an in situ proton therapy monitoring by means of in-beam PET. as already clinically implemented for the monitoring of carbon ion therapy at GSI Darmstadt.
引用
收藏
页码:21 / 36
页数:16
相关论文
共 50 条
  • [1] First in-beam PET measurement of β+ radioactivity induced by hard photon beams
    Kluge, T.
    Moeckel, D.
    Pawelke, J.
    Enghardt, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20): : N467 - N473
  • [2] In-beam PET at clinical proton beams with pile-up rejection
    Helmbrecht, Stephan
    Enghardt, Wolfgang
    Fiedler, Fine
    Lltzsche, Marc
    Pausch, Guntram
    Tintori, Carlo
    Kormoll, Thomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 202 - 217
  • [3] Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams
    Parodi, K
    Crespo, P
    Eickhoff, H
    Haberer, T
    Pawelke, J
    Schardt, D
    Enghardt, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (1-2): : 446 - 458
  • [4] Performance of a fast acquisition system for in-beam PET monitoring tested with clinical proton beams
    Piliero, M. A.
    Bisogni, M. G.
    Cerello, P.
    Del Guerra, A.
    Fiorina, E.
    Liu, B.
    Morrocchi, M.
    Pennazio, F.
    Pirrone, G.
    Wheadon, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 163 - 166
  • [5] A PET Prototype for "In-Beam" Monitoring of Proton Therapy
    Vecchio, Sara
    Attanasi, Francesca
    Belcari, Nicola
    Camarda, Manuela
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Di Rosa, Francesco
    Lanconelli, Nico
    Moehrs, Sascha
    Rosso, Valeria
    Russo, Giorgio
    Del Guerra, Alberto
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 51 - 56
  • [6] A PET prototype for in-beam monitoring of proton therapy
    Vecchio, Sara
    Attanasi, Francesca
    Belcari, Nicola
    Camarda, Manuela
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Del Guerra, Alberto
    Di Rosa, Francesco
    Lanconelli, Nico
    Moehrs, Sascha
    Rosso, Valeria
    Russo, Giorgio
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1607 - +
  • [7] In-Beam and Off-Beam PET Measurements of Target Activation by Megavolt X-Ray Beams
    Kunath, Daniela
    Kluge, Thomas
    Pawelke, Joerg
    Priegnitz, Marlen
    Enghardt, Wolfgang
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 57 - 65
  • [8] Real-time dose reconstruction in proton therapy from in-beam PET measurements
    Onecha, V. V.
    Espinosa-Rodriguez, A.
    Soneira-Landin, C.
    Arias-Valcayo, F.
    Gaitan-Dominguez, S.
    Martinez-Nouvilas, V
    Garcia-Diez, M.
    Ibanez, P.
    Espana, S.
    Sanchez-Parcerisa, D.
    Cerron-Campoo, F.
    Vera-Sanchez, J. A.
    Mazal, A.
    Udias, J. M.
    Fraile, L. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (07):
  • [9] Preliminary results of an in-beam PET prototype for proton therapy
    Attanasi, F.
    Belcari, N.
    Camarda, M.
    Cirrone, G. A. P.
    Cuttone, G.
    Del Guerra, A.
    Di Rosa, F.
    Lanconelli, N.
    Rosso, V.
    Russo, G.
    Veechio, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 296 - 299
  • [10] Suppression of random coincidences during in-beam PET measurements
    Crespo, P
    Barthel, T
    Frais-Kölbl, H
    Griesmayer, E
    Heidel, K
    Parodi, K
    Pawelke, J
    Enghardt, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2226 - 2230