Sensor arrays: an inspired idea or an objective measurement of environmental odours?

被引:20
作者
Stuetz, RM [1 ]
Nicolas, J
机构
[1] Cranfield Univ, Sch Water Sci, Cranfield MK43 0AL, Beds, England
[2] Fdn Univ Luxembourgeoise, Dept Environm Monitoring, B-6700 Arlon, Belgium
关键词
electronic nose; odours; odour assessment; olfactometry; sewage;
D O I
10.2166/wst.2001.0507
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The measure of annoyance odours from sewage tratment, landfill and agricultural practise has become highly significant in the control and prevention of dorous emissions from existing facilities and its crucial for new planning applications. Current methods (such as GC-MS analysis, H2S and NH3 measurements) provide an accurate description of chemical compositions or act as surrogates for odour strength, but tell us very little about the perceived effect, whereas olfactometry gives the right human response but is very subjective and expensive. The use of non-specific sensor arrays may offer an objective and on-line instrument for assessing olfactive annoyance. Results have shown that sensor array systems can discriminate between different odour sources (wastewater, livestock and landfill). The response patterns from these sources can be significantly different and that the intensity of sensor responses is proportional to the concentration of the volatiles. The correlation of the sensors responses against odour strengths have also shown that reasonable fits can be obtained for a range of odour concentrations (100-800,000. ou/m(3)). However, the influence of environmental fluctuations (humidity and temperature) on sensor baselines still remains an obstacle, as well as the need for periodic calibration of the sensory system and the choice of a suitable gas for different environmental odours.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 17 条
[1]   Odour measurement - Factors affecting olfactometry panel performance [J].
Bliss, PJ ;
Schulz, TJ ;
Senger, T ;
Kaye, RB .
WATER SCIENCE AND TECHNOLOGY, 1996, 34 (3-4) :549-556
[2]   Measuring wastewater quality using a sensor array: prospects for real-time monitoring [J].
Bourgeois, W ;
Stuetz, RM .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (12) :107-112
[3]  
FENNER RA, 1999, WATER ENVIRON RES, V31, P282
[4]   Automated indirect method of ammonia flux measurement for agriculture: effect of incident wind angle on airflow measurements [J].
Flint, TA ;
Persaud, KC ;
Sneath, RW .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :389-396
[5]   ASSESSMENT OF ODORS FROM LIVESTOCK WASTES BY A PHOTOIONIZATION DETECTOR, AN ELECTRONIC NOSE, OLFACTOMETRY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HOBBS, PJ ;
MISSELBROOK, TH ;
PAIN, BF .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 60 (02) :137-144
[6]  
HOBSON J, 1995, J CHART INST WATER E, V9, P458
[7]   THE ELECTRONIC NOSE AND ITS APPLICATION TO THE MANUFACTURE OF FOOD-PRODUCTS [J].
HODGINS, D ;
SIMMONDS, D .
JOURNAL OF AUTOMATIC CHEMISTRY, 1995, 17 (05) :179-185
[8]   Use of an electronic nose to measure odour concentration following application of cattle slurry to grassland [J].
Misselbrook, TH ;
Hobbs, PJ ;
Persaud, KC .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1997, 66 (03) :213-220
[9]   Using the classification model of an electronic nose to assign unknown malodours to environmental sources and to monitor them continuously [J].
Nicolas, J ;
Romain, AC ;
Wiertz, V ;
Maternova, J ;
André, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :366-371
[10]   Assessment of conducting polymer odour sensors for agricultural malodour measurements [J].
Persaud, KC ;
Khaffaf, SM ;
Hobbs, PJ ;
Sneath, RW .
CHEMICAL SENSES, 1996, 21 (05) :495-505