Oscillometric assessment of arterial stiffness in everyday clinical practice

被引:18
作者
Reshetnik, Alexander [1 ]
Gohlisch, Christopher [1 ]
Toelle, Markus [1 ]
Zidek, Walter [1 ]
Van Der Giet, Markus [1 ]
机构
[1] Charite, Dept Nephrol & Transplantat, Campus Benjamin Franklin,Hindenburgdamm 30, D-12203 Berlin, Germany
关键词
arterial stiffness; non-invasive assessment; pulse wave velocity; repeatability; Tel-O-GRAPH; PULSE-WAVE VELOCITY; AORTIC STIFFNESS; BLOOD-PRESSURE; REFLECTION; VALIDATION; ULTRASOUND; VICORDER; INDEX; RISK;
D O I
10.1038/hr.2016.115
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Measurement of carotid-femoral pulse wave velocity (cfPWV) is considered the gold standard for assessing arterial stiffness. Although widely used in clinical and observational studies, the detection of cfPWV has not yet been applied in everyday clinical practice due to technical and procedural difficulties. We, therefore, evaluated the applicability of oscillometric cfPWV assessment for everyday clinical practice. Eighty-nine patients were prospectively included in the study. Oscillometric calculations of cfPWV were performed with Tel-O-GRAPH and tonometric calculations with Sphygmocor. The accuracy, reproducibility, reliability and robustness of Tel-O-GRAPH calculations in different clinical situations were evalu?? ated. The mean study population age was 48.8 +/- 19.1 years. More than half (59.6%) of the patients were male, and 15.1% were smokers. The mean difference of PWV between devices was 0.49 +/- 1.26 m s(-1) (P<0.0001), and the Pearson correlation index was 0.86 (P<0.0001). The coefficient of variation and intraclass correlation coefficients between three single measured PWV values with the Tel-O-GRAPH and Sphygmocor were 2.38 +/- 6.13% vs. 6.3 +/- 4.33% (P<0.05) and 0.99; 0.99; and 0.99 vs. 0.78; 0.84; and 0.71, respectively. For Tel-O-GRAPH, there was no statistically significant difference between PWV in seated vs. supine positions or by experienced or inexperienced users. High reproducibility and reliability of the calculated single PWV values with Tel-O-GRAPH and considerable performance accuracy compared with Sphygmocor were observed. The reported evidence suggests that oscillometry might evolve as a favored method for the assessment of the PWV in everyday clinical practice and in clinical studies due to its ease of use, accuracy and robustness.
引用
收藏
页码:140 / 145
页数:6
相关论文
共 30 条
[1]   Comprehensive multi-modality assessment of regional and global arterial structure and function in adults born preterm [J].
Boardman, Henry ;
Birse, Katherine ;
Davis, Esther F. ;
Whitworth, Polly ;
Aggarwal, Veena ;
Lewandowski, Adam J. ;
Leeson, Paul .
HYPERTENSION RESEARCH, 2016, 39 (01) :39-45
[2]   Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method [J].
Calabia, Jordi ;
Torguet, Pere ;
Garcia, Maria ;
Garcia, Isabel ;
Martin, Nadia ;
Guasch, Bernat ;
Faur, Diana ;
Valles, Marti .
CARDIOVASCULAR ULTRASOUND, 2011, 9
[3]   A now device for automatic measurements of arterial stiffness and ankle-brachial index [J].
Cortez-Cooper, MY ;
Supak, JA ;
Tanaka, H .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (12) :1519-1522
[4]   Wave reflection quantification based on pressure waveforms alone-Methods, comparison, and clinical covariates [J].
Hametner, Bernhard ;
Wassertheurer, Siegfried ;
Kropf, Johannes ;
Mayer, Christopher ;
Holzinger, Andreas ;
Eber, Bernd ;
Weber, Thomas .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 109 (03) :250-259
[5]   Validity and repeatability of the Vicorder apparatus: a comparison with the SphygmoCor device [J].
Hickson, Stacey S. ;
Butlin, Mark ;
Broad, Jeremy ;
Avolio, Alberto P. ;
Wilkinson, Ian B. ;
McEniery, Carmel M. .
HYPERTENSION RESEARCH, 2009, 32 (12) :1079-1085
[6]   Pulse Wave Velocity Assessment by External Noninvasive Devices and Phase-Contrast Magnetic Resonance Imaging in the Obese [J].
Joly, Laure ;
Perret-Guillaume, Christine ;
Kearney-Schwartz, Anna ;
Salvi, Paolo ;
Mandry, Damien ;
Marie, Pierre-Yves ;
Karcher, Gilles ;
Rossignol, Patrick ;
Zannad, Faiez ;
Benetos, Athanase .
HYPERTENSION, 2009, 54 (02) :421-426
[7]   Validation of the integration of technology that measures additional "vascular" indices into an ambulatory blood pressure monitoring system [J].
Kotovskaya, Yulia V. ;
Kobalava, Zhanna D. ;
Orlov, Artemy V. .
MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2014, 7 :91-97
[8]   Ambulatory arterial stiffness in chronic kidney disease: a methodological review [J].
Laszlo, Andrea ;
Reusz, Gyoergy ;
Nemcsik, Janos .
HYPERTENSION RESEARCH, 2016, 39 (04) :192-198
[9]   Comparative reproducibility of the noninvasive ultrasound methods for the assessment of vascular function [J].
Magda, Stefania L. ;
Ciobanu, Andrea O. ;
Florescu, Maria ;
Vinereanu, Dragos .
HEART AND VESSELS, 2013, 28 (02) :143-150
[10]   2013 ESH/ESC Guidelines for the management of arterial hypertension [J].
Taylor, Jennifer .
EUROPEAN HEART JOURNAL, 2013, 34 (28) :2108-2109