Absolute Polarimeter for the Proton-Beam Energy of 200 MeV

被引:0
|
作者
Zelenski, A. N. [1 ]
Atoian, G. [1 ]
Bogdanov, A. A. [2 ]
Nurushev, S. B. [2 ]
Pylaev, F. S. [2 ]
Raparia, D. [1 ]
Runtso, M. F. [2 ]
Stephenson, E. [3 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
[2] Natl Res Nucl Univ MEPhI, Moscow 115409, Russia
[3] IUCF, Bloomington, IN USA
关键词
SCATTERING;
D O I
10.1134/S1063778813120156
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A polarimeter is upgraded and tested in a 200-MeV polarized-proton beam at the accelerator-collider facility of the Brookhaven National Laboratory. The polarimeter is based on the elastic polarized-proton scattering on a carbon target at an angle of 16.2 degrees, in which case the analyzing power is close to unity and was measured to a very high degree of precision. It is shown that, in the energy range of 190-205 MeV, the absolute polarization can be measured to a precision better than +/- 0.5%.
引用
收藏
页码:1490 / 1496
页数:7
相关论文
共 50 条
  • [1] Absolute polarimeter for the proton-beam energy of 200 MeV
    A. N. Zelenski
    G. Atoian
    A. A. Bogdanov
    S. B. Nurushev
    F. S. Pylaev
    D. Raparia
    M. F. Runtso
    E. Stephenson
    Physics of Atomic Nuclei, 2013, 76 : 1490 - 1496
  • [2] Precision, absolute proton polarization measurements at 200 MeV beam energy
    Zelenski, A.
    Atoian, G.
    Bogdanov, A.
    Raparia, D.
    Runtso, M.
    Stephenson, E.
    19TH INTERNATIONAL SPIN PHYSICS SYMPOSIUM (SPIN2010), PT 2, 2011, 295
  • [3] LAMB SHIFT POLARIMETER OF SLOW PROTON-BEAM
    PLISS, YA
    SOROKO, LM
    NUCLEAR INSTRUMENTS & METHODS, 1976, 135 (03): : 497 - 501
  • [4] ABSOLUTE DOSIMETRY IN A CLINICAL PROTON-BEAM
    VERHEY, L
    KUBO, H
    MEDICAL PHYSICS, 1985, 12 (04) : 546 - 546
  • [5] ENERGY MEASUREMENT OF 50 MEV PROTON-BEAM WITH A NAI(TL) SCINTILLATOR
    HA, JH
    KIM, JC
    KIM, YK
    YOUN, M
    CHAE, SJ
    CHUNG, HT
    CHOI, JH
    LEE, CS
    KWON, JU
    MOON, CB
    CHAI, JS
    KIM, YS
    LEE, JD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (03): : 411 - 414
  • [6] ACCIDENTAL IRRADIATION OF SKIN ON HANDS WITH A PROTON-BEAM OF 4 MEV ENERGY
    DZIUK, E
    MERTA, A
    BOCIAN, E
    STRAHLENTHERAPIE, 1973, 146 (06) : 685 - 692
  • [7] PROTON-BEAM ENERGY ANALYZER
    BELAN, VN
    BOLOTIN, LI
    KISELEV, VA
    LINNIK, AF
    USKOV, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1988, 31 (06) : 1396 - 1398
  • [8] CHARACTERISTICS OF NEUTRON BEAM GENERATED BY 500 MEV PROTON-BEAM
    INADA, T
    HAYAKAWA, Y
    TADA, J
    KUBOTA, N
    HIRAOKA, T
    SATO, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 499 - 504
  • [9] A 300-MEV PROTON-BEAM LINE WITH ENERGY DEGRADER FOR MEDICAL SCIENCE
    KURIHARA, D
    SUWA, S
    TACHIKAWA, A
    TAKADA, Y
    TAKIKAWA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1983, 22 (10): : 1599 - 1605
  • [10] AN ELECTROSTATIC BEAM SPLITTER FOR THE SIN 590 MEV PROTON-BEAM LINE
    OLIVO, M
    ROHRER, U
    STEINER, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 3094 - 3096