A novel method for ABO-incompatible heart transplantation

被引:13
作者
Robertson, Alex [1 ]
Issitt, Richard [1 ]
Crook, Richard [1 ]
Gustafsson, Kenth [2 ]
Eddaoudi, Ayad [3 ]
Tsang, Victor [4 ,5 ]
Burch, Michael [6 ,7 ]
机构
[1] Great Ormond St Hosp Sick Children, Dept Perfus, London, England
[2] UCL, Inst Cardiovasc Sci, Dept Mol Immunol, London, England
[3] UCL, Inst Cardiovasc Sci, Dept Flow Cytometry, London, England
[4] Great Ormond St Hosp Sick Children, Dept Cardiothorac Surg, London, England
[5] UCL, Inst Cardiovasc Sci, London, England
[6] Great Ormond St Hosp Sick Children, Dept Transplantat, London, England
[7] UCL, Inst Child Hlth, Dept Paediat Cardiol, London, England
关键词
cardiopulmonary bypass; heart transplantation; immunoadsorption; isohemagglutinin; ABO mismatch transplantation; paediatric; KIDNEY-TRANSPLANTATION; ANTIBODIES; PERFUSION;
D O I
10.1016/j.healun.2017.05.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Since 1996, ABO-incompatible heart transplantation has been undertaken by performing whole-body plasma exchange to remove isohemagglutinins using the cardiopulmonary bypass (CPB) circuit at the time of transplantation. This requires large volumes of donated blood and blood products, causes hemodynamic instability during the exchange transfusion, and limits practical use to small children. We sought to determine the efficacy of anti-A/B immunoadsorption within the CPB circuit on removal of isohemagglutinins in an ex vivo setting before its use clinically. METHODS: An anti-A/B immunoadsorption column was placed into a CPB circuit mimicking a typical ABO-incompatible transplant patient, which had been primed with type O whole human blood. Samples were taken for determination of isohemagglutinin titers following each plasma volume pass through the anti-A/B immunoadsorption column. RESULTS: There was a linear decrease of at least 1 dilution seen in both anti-A and anti-B IgG and IgM antibodies with each plasma volume pass through the column. This predictable removal allowed the formulation of selection criteria for ABO-incompatible heart transplantation given the reciprocal of titer and patient weight. This degree of predictability allowed us to use it successfully in the clinical setting, reducing antibodies to an undetectable level during ABO-incompatible heart transplantation. CONCLUSIONS: The incorporation of an anti-A/B immunoadsorption column into the extracorporeal circuit reduces allogeneic blood product requirement for ABO-incompatible heart transplantation, while providing efficacious removal of anti-A and anti-B isohemagglutinins. This can be undertaken within the time period of CPB before graft reperfusion and expands the potential recipient pool to larger patients with higher isohemagglutinin titers. Crown Copyright (C) 2018 Published by Elsevier Inc. on behalf of International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:451 / 457
页数:7
相关论文
共 16 条
[1]   Heart transplantation across antibodies against human leukocyte antigen and ABO-post-transplant follow-up of donor reactive antibodies [J].
Bucin, D ;
Johansson, S ;
Lindberg, LO .
XENOTRANSPLANTATION, 2006, 13 (02) :101-104
[2]   Heart transplantation across the antibodies against HLA and ABO [J].
Bucin, D ;
Johansson, S ;
Malm, T ;
Jögi, P ;
Johansson, J ;
Westrin, P ;
Lindberg, LO ;
Olsson, AK ;
Gelberg, J ;
Peres, V ;
Harling, S ;
Bennhagen, R ;
Kornhall, B ;
Ekmehag, B ;
Kurkus, J ;
Otto, G .
TRANSPLANT INTERNATIONAL, 2006, 19 (03) :239-244
[3]  
COOPER DKC, 1990, J HEART TRANSPLANT, V9, P376
[4]   DEVELOPMENTAL PATTERNS OF ABO ISOAGGLUTININS IN NORMAL CHILDREN CORRELATED WITH EFFECTS OF AGE, SEX, AND MATERNAL ISOAGGLUTININS [J].
FONG, SW ;
QAQUNDAH, BY ;
TAYLOR, WF .
TRANSFUSION, 1974, 14 (06) :551-559
[5]   ABO-incompatible heart transplantation: a perfusion strategy [J].
Foreman, C ;
Gruenwald, C ;
West, L .
PERFUSION-UK, 2004, 19 (01) :69-72
[6]   Incompatible ABO-plasma exchange and its impact on patient selection in paediatric cardiac transplantation [J].
Issitt, R. W. ;
Crook, R. M. ;
Cross, N. T. ;
Shaw, M. ;
Robertson, A. ;
Burch, M. ;
Hsia, T. Y. ;
Tsang, V. T. .
PERFUSION-UK, 2012, 27 (06) :480-485
[7]   Comparing the tube and gel techniques for ABO antibody titration, as performed in three European centers [J].
Kumlien, Gunilla ;
Wilpert, Jochen ;
Safwenberg, Jan ;
Tyden, Gunnar .
TRANSPLANTATION, 2007, 84 (12) :S17-S19
[8]   Increased mortality, postoperative morbidity, and cost after red blood cell transfusion in patients having cardiac surgery [J].
Murphy, Gavin J. ;
Reeves, Barnaby C. ;
Rogers, Chris A. ;
Rizvi, Syed I. A. ;
Culliford, Lucy ;
Angelini, Gianni D. .
CIRCULATION, 2007, 116 (22) :2544-2552
[9]   Optimal Perfusion During Cardiopulmonary Bypass: An Evidence-Based Approach [J].
Murphy, Glenn S. ;
Hessel, Eugene A., II ;
Groom, Robert C. .
ANESTHESIA AND ANALGESIA, 2009, 108 (05) :1394-1417
[10]   ABO-incompatible heart transplantation in infants: Analysis of the United Network for Organ Sharing database [J].
Patel, Nishant D. ;
Weiss, Eric S. ;
Scheel, Janet ;
Cameron, Duke E. ;
Vricella, Luca A. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (10) :1085-1089