Advanced lifetime PSP imaging system for pressure and temperature field measurement

被引:26
作者
Mitsuo, Kazunori
Asai, Keisuke
Takahashi, Akira
Mizushima, Hiroshi
机构
[1] Japan Aerosp Explorat Agcy, Aerodynam Res Grp, Inst Aerosp Technol, Chofu, Tokyo 1828522, Japan
[2] Tohoku Univ, Sch Engn, Dept Aerosp Engn, Sendai, Miyagi 9808579, Japan
[3] Hamamatsu Photon KK, Syst Div, Hamamatsu, Shizuoka 4313196, Japan
关键词
pressure-sensitive paint; lifetime imaging; delta-wing; pressure and temperature measurement;
D O I
10.1088/0957-0233/17/6/S07
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The newly designed lifetime imaging system ( LIS), which was composed of a multi-gated CCD camera and LED illuminators, has been developed to measure simultaneously pressure and temperature field from luminescent lifetime decay of pressure-sensitive paint (PSP). The new system could reduce the measurement error due to shot noise of a CCD and laser speckle, compared to the previous lifetime imaging system. Optimization of PSP film thickness on white basecoat was also conducted for improving measurement accuracy, and could minimize the measurement error. As a verification test, pressure and temperature images on a simple delta wing were visualized by the newly designed LIS. The quality of the pressure image was considerably improved in comparison with that measured by the previous system. These results indicated that the new LIS was a practical measurement tool to acquire simultaneously pressure and temperature field on an aerodynamic model surface.
引用
收藏
页码:1282 / 1291
页数:10
相关论文
共 14 条
[1]   Photophysical and photochemical properties of optical oxygen pressure sensor of platinum porphyrin-isobutylmethacrylate-trifluoroethylmethacrylate copolymer film [J].
Amao, Y ;
Asai, K ;
Miyashita, T ;
Okura, I .
POLYMER JOURNAL, 1999, 31 (12) :1267-1269
[2]   MOSAIC Project - Summary of Phase One Program [J].
Asai, K ;
Okura, I ;
Mizushima, H .
ICIASF'03 RECORD: 20TH INTERNATIONAL CONGRESS ON INSTRUMENTATION IN AEROSPACE SIMULATION FACILITIES, 2003, :89-94
[3]  
BELL HJ, 2001, 19 INT C INSTR AER S, P5
[4]   Surface pressure measurements using luminescent coatings [J].
Bell, JH ;
Schairer, ET ;
Hand, LA ;
Mehta, RD .
ANNUAL REVIEW OF FLUID MECHANICS, 2001, 33 :155-206
[5]   EFFECTS OF POLYMER MATRICES ON THE TIME-RESOLVED LUMINESCENCE OF A RUTHENIUM COMPLEX QUENCHED BY OXYGEN [J].
DRAXLER, S ;
LIPPITSCH, ME ;
KLIMANT, I ;
KRAUS, H ;
WOLFBEIS, OS .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (10) :3162-3167
[6]   Pressure sensitive paint systems for pressure distribution measurements in wind tunnels and turbomachines [J].
Engler, RH ;
Klein, C ;
Trinks, O .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (07) :1077-1085
[7]  
Holmes JW, 1998, AERONAUT J, V102, P189
[8]  
Lakowicz J.R., 1999, PRINCIPLES FLUORESCE, P280
[9]  
LUI T, 1997, APPL MECH REV, V50, P227
[10]   Three-gate lifetime imaging system for pressure-sensitive paint measurements [J].
Mitsuo, K ;
Asai, K ;
Suzuki, H ;
Mizushima, H .
AIAA JOURNAL, 2006, 44 (03) :600-607