Aptamer-based microcantilever-array biosensor for profenofos detection

被引:48
|
作者
Li, Chao [1 ]
Zhang, Guangping [1 ]
Wu, Shangquan [1 ]
Zhang, Qingchuan [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Mech, CAS Key Lab Mech Behav & Design Mat, Hefei 230027, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Aptamer; Microcantilever sensor; Surface stress; Label-free; Profenofos; LABEL-FREE DETECTION; HEAVY-METAL IONS; ORGANOPHOSPHORUS PESTICIDES; FLUORESCENCE POLARIZATION; SINGLE; SENSOR; PHASE; ASSAY; WATER; CHROMATOGRAPHY;
D O I
10.1016/j.aca.2018.02.072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Profenofos, a highly poisonous organophosphorus pesticide, has been widely used in agricultural production. These pesticide residues have seriously influenced food security and threatened human health, and new methods with high sensitivity are greatly needed to detect profenofos. Here, we developed an aptamer-based microcantilever-array sensor operated in stress mode to detect profenofos, with advantages of being a label-free, highly sensitive, one-step immobilization method capable of quantitative and real-time detection. The microcantilevers were functionalized with a profenofos-specific aptamer (SS2-55), and then the specific binding of profenofos to aptamer induced a deflection of the microcantilever, which was monitored using an optical method in a real-time manner. The microcantilever deflection showed a positive relationship with profenofos concentration, and the detection limit was low to 1.3 ng mL(-1) (3.5 nM) for profenofos, which was much lower than other aptamer-based detection methods. The selectivity of the sensor was verified with another organophosphorus pesticide. Additionally, we successfully detected profenofos dissolved in vegetable-soak solution. Our results showed that this aptamer-based microcantilever-array sensor is a convenient and label-free method for detecting profenofos in small amounts and has great potential for food-security applications. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 50 条
  • [1] Aptamer-based microcantilever-array biosensor for ultra-sensitive and rapid detection of okadaic acid
    Wang, Yu
    Rao, Depeng
    Wu, Xiaoping
    Zhang, Qingchuan
    Wu, Shangquan
    MICROCHEMICAL JOURNAL, 2021, 160
  • [2] Aptamer-based microcantilever array biosensor for detection of fumonisin B-1
    Chen, Xuejuan
    Bai, Xiaojing
    Li, Huiyan
    Zhang, Bailin
    RSC ADVANCES, 2015, 5 (45): : 35448 - 35452
  • [3] Aptamer-based microcantilever biosensor for ultrasensitive detection of tumor marker nucleolin
    Li, Huiyan
    Bai, Xiaojing
    Wang, Nan
    Chen, Xuejuan
    Li, Jing
    Zhang, Zhe
    Tang, Jilin
    TALANTA, 2016, 146 : 727 - 731
  • [4] Label-free aptamer-based detection of microcystin-LR using a microcantilever array biosensor
    Zhang, Guanping
    Li, Chao
    Wu, Shangquan
    Zhang, Qingchuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 42 - 47
  • [5] Aptamer-Based Fluorescence Assay for Detection of Isocarbophos and Profenofos
    Wang Li
    Ye Hua
    Sang Hong-Qing
    Wang Dan-Dan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (05) : 799 - 803
  • [6] Label-free detection of liver cancer cells by aptamer-based microcantilever biosensor
    Chen, Xuejuan
    Pan, Yangang
    Liu, Huiqing
    Bai, Xiaojing
    Wang, Nan
    Zhang, Bailin
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 353 - 358
  • [7] Aptamer-Based Biosensor for Detection of Mycotoxins
    Guo, Xiaodong
    Wen, Fang
    Zheng, Nan
    Saive, Matthew
    Fauconnier, Marie-Laure
    Wang, Jiaqi
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [8] Aptamer-Based Biosensor
    Zheng Jing
    He Pingang
    Fang Yuzhi
    PROGRESS IN CHEMISTRY, 2009, 21 (04) : 732 - 738
  • [9] Colorimetric Detection of Hemoglobin by Aptamer-Based Biosensor
    Teniou, Ahlem
    Rhouati, Amina
    Madi, Ibrahim Alaa Eddine
    Mouhoub, Riane
    Catanante, Gaelle
    Mashifana, Tebogo
    Vasseghian, Yasser
    Berkani, Mohammed
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (11) : 4704 - 4712
  • [10] An aptamer-based electrochemiluminescent biosensor for ATP detection
    Yao, Wu
    Wang, Lun
    Wang, Haiyan
    Zhang, Xiaolei
    Li, Ling
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (11): : 3269 - 3274