Application of oriented and random antibody immobilization methods in immunosensor design

被引:54
作者
Baniukevic, Julija [1 ]
Kirlyte, Justina [1 ]
Ramanavicius, Arunas [1 ,2 ]
Ramanaviciene, Almira [1 ]
机构
[1] Vilnius State Univ, Fac Chem, NanoTechnas Ctr Nanotechnol & Mat Sci, LT-03225 Vilnius, Lithuania
[2] State Res Inst Ctr Phys Sci & Technol, Inst Semicond Phys, Dept Mat Sci & Elect Engn, Lab BioNanoTechnol, LT-02300 Vilnius, Lithuania
关键词
SPR; Immunosensor; Antibody immobilization; BLV; SURFACE-PLASMON RESONANCE; BOVINE LEUKEMIA-VIRUS; IMMUNOGLOBULIN-G; DAIRY-CATTLE; FRAGMENTS; INFECTION; CELLS; SPR; MONOLAYER; BIOSENSOR;
D O I
10.1016/j.snb.2013.03.126
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensor for the determination of bovine leukemia virus (BLV) antigen (gp51) using surface plasmon resonance (SPR) equipment and SPR-chip modified by oriented and randomly immobilized antibodies (anti-gp51) was developed. Different conditions of anti-gp51 reduction by 2-mercaptoethanol (2-ME) and dithiothreitol (DTT) solutions were compared and explored. The best gp51 detection sensitivity was monitored using SPR-chip modified with oriented antibody fragments (frag-anti-gp51) obtained after reduction with DTT at 50 mM concentration. The SPR sensor could detect gp51 antigenin a range from 0.01 to 0.5 mg/mL. The developed SPR sensor offered the limit of detection (LOD) as low as 0.0028 mg/mL, while the limit of quantification was as low as 0.0092 mg/mL with very good repeatability during the three detection-regeneration cycles (1-4%). Oriented immobilization of frag-anti-gp51 was found to be more suitable for the design of SPR-immunosensor for the detection of gp51 if compared with random immobilization of anti-gp51. This method was successfully applied for the detection of gp51 in blood serum samples in a rapid, reliable and selective manner. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 33 条
[31]   Site-directed immobilisation of antibody fragments for detection of C-reactive protein [J].
Vikholm-Lundin, I ;
Albers, WM .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) :1141-1148
[32]   Sensors and biosensors for the determination of small molecule biological toxins [J].
Wang, Xiang-Hong ;
Wang, Shuo .
SENSORS, 2008, 8 (09) :6045-6054
[33]   Oriented immobilization of immunoglobulin G onto the cuvette surface of the resonant mirror biosensor through layer-by-layer assembly of multilayer films [J].
Wu, Bao-Yan ;
Hou, Shi-Hua ;
Huang, Liang ;
Yin, Feng ;
Zhao, Zi-Xia ;
Anzai, Jun-Ichi ;
Chen, Qiang .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (07) :1065-1069