Application of oriented and random antibody immobilization methods in immunosensor design

被引:54
作者
Baniukevic, Julija [1 ]
Kirlyte, Justina [1 ]
Ramanavicius, Arunas [1 ,2 ]
Ramanaviciene, Almira [1 ]
机构
[1] Vilnius State Univ, Fac Chem, NanoTechnas Ctr Nanotechnol & Mat Sci, LT-03225 Vilnius, Lithuania
[2] State Res Inst Ctr Phys Sci & Technol, Inst Semicond Phys, Dept Mat Sci & Elect Engn, Lab BioNanoTechnol, LT-02300 Vilnius, Lithuania
关键词
SPR; Immunosensor; Antibody immobilization; BLV; SURFACE-PLASMON RESONANCE; BOVINE LEUKEMIA-VIRUS; IMMUNOGLOBULIN-G; DAIRY-CATTLE; FRAGMENTS; INFECTION; CELLS; SPR; MONOLAYER; BIOSENSOR;
D O I
10.1016/j.snb.2013.03.126
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensor for the determination of bovine leukemia virus (BLV) antigen (gp51) using surface plasmon resonance (SPR) equipment and SPR-chip modified by oriented and randomly immobilized antibodies (anti-gp51) was developed. Different conditions of anti-gp51 reduction by 2-mercaptoethanol (2-ME) and dithiothreitol (DTT) solutions were compared and explored. The best gp51 detection sensitivity was monitored using SPR-chip modified with oriented antibody fragments (frag-anti-gp51) obtained after reduction with DTT at 50 mM concentration. The SPR sensor could detect gp51 antigenin a range from 0.01 to 0.5 mg/mL. The developed SPR sensor offered the limit of detection (LOD) as low as 0.0028 mg/mL, while the limit of quantification was as low as 0.0092 mg/mL with very good repeatability during the three detection-regeneration cycles (1-4%). Oriented immobilization of frag-anti-gp51 was found to be more suitable for the design of SPR-immunosensor for the detection of gp51 if compared with random immobilization of anti-gp51. This method was successfully applied for the detection of gp51 in blood serum samples in a rapid, reliable and selective manner. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 33 条
[1]   Evaluation of intact- and fragmented-antibody based immunosensors by total internal reflection ellipsometry [J].
Balevicius, Zigmas ;
Ramanaviciene, Almira ;
Baleviciute, Ieva ;
Makaraviciute, Asta ;
Mikoliunaite, Lina ;
Ramanavicius, Arunas .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) :555-562
[2]   Antiviral activity of Shiga toxin requires enzymatic activity and is associated with increased permeability of the target cells [J].
Basu, I ;
Ferens, WA ;
Stone, DM ;
Hovde, CJ .
INFECTION AND IMMUNITY, 2003, 71 (01) :327-334
[3]   Comparison of random and oriented immobilisation of antibody fragments on mixed self-assembled monolayers [J].
Bonroy, Kristien ;
Frederix, Filip ;
Reekmans, Gunter ;
Dewolf, Ellen ;
De Palma, Randy ;
Borghs, Gustaaf ;
Declerck, Paul ;
Goddeeris, Bruno .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 312 (1-2) :167-181
[4]   Immobilization of Protein A on SAMS for the elaboration of immunosensors [J].
Briand, Elisabeth ;
Salmain, Michele ;
Compere, Chantal ;
Pradier, Claire-Marie .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2006, 53 (02) :215-224
[5]   In vitro infection of cells of the monocytic/macrophage lineage with bovine leukaemia virus [J].
Doménech, A ;
Goyache, J ;
Llames, L ;
Payá, MJ ;
Suárez, G ;
Gómez-Lucía, E .
JOURNAL OF GENERAL VIROLOGY, 2000, 81 :109-118
[6]   SURFACE-PLASMON RESONANCE AND IMMUNOSENSORS [J].
FLANAGAN, MT ;
PANTELL, RH .
ELECTRONICS LETTERS, 1984, 20 (23) :968-970
[7]   Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin [J].
Gobi, K. Vengatajalabathy ;
Iwasaka, Hiroyuki ;
Miura, Norio .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1382-1389
[8]   Natural progression of Bovine Leukemia Virus infection in Argentinean dairy cattle [J].
Gutierrez, Geronimo ;
Alvarez, Irene ;
Politzki, Romina ;
Lomonaco, Marina ;
Dus Santos, Maria Jose ;
Rondelli, Flavia ;
Fondevila, Norberto ;
Trono, Karina .
VETERINARY MICROBIOLOGY, 2011, 151 (3-4) :255-263
[9]   Signal enhancement of surface plasmon resonance-based immunoassays for the allergen detection [J].
Huang, Haizhen ;
Ran, Pixin ;
Liu, Zhigang .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (02) :417-423
[10]   Oriented immobilization of antibodies by a self-assembled monolayer of 2-(biotinamido)ethanethiol for immunoarray preparation [J].
Jung, SH ;
Son, HY ;
Yuk, JS ;
Jung, JW ;
Kim, KH ;
Lee, CH ;
Hwang, H ;
Ha, KS .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2006, 47 (01) :107-111