Simultaneous determination of low levels of methotrexate and cyclophosphamide in human urine by micro liquid chromatography/electrospray ionization tandem mass spectrometry

被引:44
作者
Barbieri, A
Sabatini, L
Indiveri, P
Bonfiglioli, R
Lodi, V
Violante, FS
机构
[1] Univ Bologna, Serv Sicurezza Igiene & Med Lavoro, I-40138 Bologna, Italy
[2] Univ Bologna, St Orsola Malpighi Hosp, Occupat Hlth Unit, I-40138 Bologna, Italy
关键词
D O I
10.1002/rcm.2527
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to develop and validate a novel solid-phase extraction (SPE) liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of two antineoplastic drugs, cyclophosphamide (CP) and methotrexate (MTX), in human urine using trophosphamide as internal standard. The method showed good precision and accuracy (mean RSD 2.8% and 0.9%; bias 2.7% and 2.4% for MTX and CP, respectively). The lower limits of detection obtained, 0.2 mu g/L-urine for MTX and 0.04 mu g/L-urine, for CP, were lower than the best previously reported values. The use of a 96-well SPE plate for matrix purification ensures a high throughput (50 samples/day), allowing the routine biological monitoring of CP and MTX as measures of occupational exposure at very low levels. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1889 / 1893
页数:5
相关论文
共 18 条
[1]  
[Anonymous], GUID IND BIOAN METH
[2]   Simultaneous quantification of cyclophosphamide, 4-hydroxycyclophosphamide, N,N′,N"-triethylenethiophosphoramide (thiotepa) and N,N′,N"-triethylenephosphoramide (tepa) in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry [J].
de Jonge, ME ;
van Dam, SM ;
Hillebrand, MJX ;
Rosing, H ;
Huitema, ADR ;
Rodenhuis, S ;
Beijnen, JH .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (03) :262-271
[3]  
*DHHS NIOSH, 2004, PUBL DHHS NIOSH, V102
[4]  
GABRIELE P, 1993, ORAL ONCOL, V10, P153, DOI DOI 10.1016/0964-1955(93)90041-C
[5]  
*IARC, 2000, MON EV CARC RISKS HU, V76
[6]   Quantification of cyclophosphamide and its metabolites in urine using liquid chromatography/tandem mass spectrometry [J].
Kasel, D ;
Jetter, A ;
Harlfinger, S ;
Gebhardt, W ;
Fuhr, U .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (13) :1472-1478
[7]   BLADDER-CANCER IN A 39-YEAR-OLD FEMALE PHARMACIST [J].
LEVIN, LI ;
HOLLY, EA ;
SEWARD, JP .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1993, 85 (13) :1089-1091
[8]  
*OSHA, 2000, TECHN MAN HOSP INV 6
[9]   Uptake of antineoplastic agents in pharmacy and hospital personnel. Part I: monitoring of urinary concentrations [J].
Pethran, A ;
Schierl, R ;
Hauff, K ;
Grimm, CH ;
Boos, KS ;
Nowak, D .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2003, 76 (01) :5-10
[10]   A new high-performance liquid chromatographic/electrospray ionization tandem mass spectrometric method for the simultaneous determination of cyclophosphamide, methotrexate and 5-fluorouracil as markers of surface contamination for occupational exposure monitoring [J].
Sabatini, L ;
Barbieri, A ;
Tosi, M ;
Violante, FS .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (05) :669-674