Trabecular bone structure analysis of the spine using clinical MDCT: can it predict vertebral bone strength?

被引:29
作者
Baum, Thomas [1 ]
Graebeldinger, Martin [1 ]
Raeth, Christoph [2 ]
Garcia, Eduardo Grande [1 ,3 ]
Burgkart, Rainer [3 ]
Patsch, Janina M. [4 ]
Rummeny, Ernst J. [1 ]
Link, Thomas M. [5 ]
Bauer, Jan S. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Inst Radiol, D-81675 Munich, Germany
[2] Max Planck Inst Extraterr Phys, D-85748 Garching, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Klin Orthopad & Sportorthopad, Abt Biomech, D-81675 Munich, Germany
[4] Med Univ Wien, Univ Klin Radiodiagnost, A-1090 Vienna, Austria
[5] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Musculoskeletal & Quantitat Imaging Res Grp, San Francisco, CA 94107 USA
关键词
Osteoporosis; Vertebral bone strength; HR-pQCT; MDCT; Trabecular bone structure; X-RAY ABSORPTIOMETRY; QUALITY-OF-LIFE; MINERAL DENSITY; DISTAL RADIUS; BIOMECHANICAL STRENGTH; COMPUTED-TOMOGRAPHY; PROXIMAL FEMUR; IN-VIVO; CT; WOMEN;
D O I
10.1007/s00774-013-0465-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent technical improvements have made it possible to determine trabecular bone structure parameters of the spine using clinical multi-detector computed tomography (MDCT). Therefore, the purpose of this study was to analyze trabecular bone structure parameters obtained from clinical MDCT in relation to high resolution peripheral quantitative computed tomography (HR-pQCT) as a standard of reference and to investigate whether clinical MDCT can predict vertebral bone strength. Fourteen functional spinal segment units between T7 and L3 were harvested from 14 formalin-fixed human cadavers (11 women and 3 men; age 84 +/- A 10 years). All functional spinal segment units were examined using HR-pQCT (isotropic voxel size of 41 mu m(3)) and a clinical whole-body MDCT (interpolated voxel size of 146 x 146 x 300 mu m(3)). Trabecular bone structure analyses (histomorphometric and texture measures) were performed in the HR-pQCT as well as MDCT images. Vertebral failure load (FL) of the functional spinal segment units was determined in an uniaxial biomechanical test. The HR-pQCT and MDCT derived trabecular bone structure parameters showed correlations ranging from r = 0.60 to r = 0.90 (p < 0.05). Correlations between trabecular bone structure parameters and FL amounted up to r = 0.86 (p < 0.05) using the HR-pQCT images, and up to r = 0.79 (p < 0.05) using the MDCT images. Correlation coefficients of FL versus trabecular bone structure parameters obtained with HR-pQCT and MDCT were not significantly different (p > 0.05). In this cadaver model, the spatial resolution of clinically available whole-body MDCT scanners was suitable for trabecular bone structure analysis of the spine and to predict vertebral bone strength.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 47 条
[1]   The influence of osteoporotic fractures on health-related quality of life in community-dwelling men and women across Canada [J].
Adachi, JD ;
Ioannidis, G ;
Berger, C ;
Joseph, L ;
Papaioannou, A ;
Pickard, L ;
Papadimitropoulos, EA ;
Hopman, W ;
Poliquin, S ;
Prior, JC ;
Hanley, DA ;
Olszynski, WP ;
Anastassiades, T ;
Brown, JP ;
Murray, T ;
Jackson, SA ;
Tenenhouse, A .
OSTEOPOROSIS INTERNATIONAL, 2001, 12 (11) :903-908
[2]   Quantitative computed tomography [J].
Adams, Judith E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) :415-424
[3]  
[Anonymous], 1994, World Health Organ Tech Rep Ser, V843, P1
[4]  
[Anonymous], 2001, SOUTH MED J, V94, P569, DOI DOI 10.1097/00007611-200106000-00005
[5]   The role of cortical bone and its microstructure in bone strength [J].
Augat, Peter ;
Schorlemmer, Sandra .
AGE AND AGEING, 2006, 35 :27-31
[6]   Analysis of trabecular bone structure with multidetector spiral computed tomography in a simulated soft-tissue environment [J].
Bauer, Jan S. ;
Link, Thomas M. ;
Burghardt, Andrew ;
Henning, Tobias D. ;
Mueller, Dirk ;
Majumdar, Sharmila ;
Prevrhal, Sven .
CALCIFIED TISSUE INTERNATIONAL, 2007, 80 (06) :366-373
[7]   Advances in osteoporosis imaging [J].
Bauer, Jan S. ;
Link, Thomas M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) :440-449
[8]   Structural analysis of trabecular bone of the proximal femur using multislice computed tomography:: A comparison with dual x-ray absorptiometry for predicting biomechanical strength in vitro [J].
Bauer, JS ;
Kohlmann, S ;
Eckstein, F ;
Mueller, D ;
Lochmüller, EM ;
Link, T .
CALCIFIED TISSUE INTERNATIONAL, 2006, 78 (02) :78-89
[9]  
Bauer JS, 2004, ROFO-FORTSCHR RONTG, V176, P709, DOI 10.1055/s-2004-813079
[10]   Automated 3D trabecular bone structure analysis of the proximal femur-prediction of biomechanical strength by CT and DXA [J].
Baum, T. ;
Carballido-Gamio, J. ;
Huber, M. B. ;
Mueller, D. ;
Monetti, R. ;
Raeth, C. ;
Eckstein, F. ;
Lochmueller, E. M. ;
Majumdar, S. ;
Rummeny, E. J. ;
Link, T. M. ;
Bauer, J. S. .
OSTEOPOROSIS INTERNATIONAL, 2010, 21 (09) :1553-1564