Disc calibration for digital templating in hip replacement

被引:22
作者
Kulkarni, A. [1 ]
Partington, P. [1 ]
Kelly, D. [2 ]
Muller, S. [1 ]
机构
[1] Wansbeck Gen Hosp, Ashington NE63 9JJ, England
[2] Newcastle Univ, Sch Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 12期
关键词
D O I
10.1302/0301-620X.90B12.20238
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by 'reverse calibration' of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere. The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs.
引用
收藏
页码:1623 / 1626
页数:4
相关论文
共 7 条
[1]   A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating [J].
Conn, KS ;
Clarke, MT ;
Hallett, JP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (02) :269-272
[2]   Preoperative planning for primary total hip arthroplasty [J].
Della Valle, AG ;
Padgett, DE ;
Salvati, EA .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (07) :455-462
[3]  
EDWARDS M, DEP HLTH PACS IMPLEM
[4]   Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs [J].
Oddy, MJ ;
Jones, MJ ;
Pendegrass, CJ ;
Pilling, JR ;
Wimhurst, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05) :581-585
[5]   Comparison of analog and digital preoperative planning in total hip and knee arthroplasties - A prospective study of 173 hips and 65 total knees [J].
The, B ;
Diercks, RL ;
van Ooijen, PMA ;
van Horn, JR .
ACTA ORTHOPAEDICA, 2005, 76 (01) :78-84
[6]   Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice [J].
White, SP ;
Shardlow, DL .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2005, 87 (01) :53-54
[7]   Accurate scaling of digital radiographs of the pelvis - A prospective trial of two methods [J].
Wimsey, S. ;
Pickard, R. ;
Shaw, G. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (11) :1508-1512