A low-cost, fast, disposable and sensitive biosensor study: flow injection analysis of glucose at poly-methylene blue-modified pencil graphite electrode

被引:21
作者
Dilgin, Didem Giray [1 ]
Ertek, Bensu [2 ]
Dilgin, Yusuf [2 ]
机构
[1] Canakkale Onsekiz Mart Univ, Biga Vocat Sch, Biga Canakkale, Turkey
[2] Canakkale Onsekiz Mart Univ, Chem Dept, Fac Sci & Art, TR-17020 Canakkale, Turkey
关键词
Pencil graphite electrode; Modified electrode; Glucose biosensor; NADH; Flow injection analysis; Amperometry; WALLED CARBON NANOTUBES; ELECTROCATALYTIC OXIDATION; AMPEROMETRIC BIOSENSORS; ELECTROCHEMICAL SENSORS; TRANSFER MEDIATOR; DEHYDROGENASE; NADH; SYSTEM; ENZYME; NANOCOMPOSITE;
D O I
10.1007/s13738-018-1335-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, firstly methylene blue (MB) was electropolymerized onto pencil graphite electrode (PGE) surface for the electrocatalytic oxidation of NADH. Cyclic voltammograms show that oxidation potential of NADH at Poly-MB/PGE shifted to negative direction about 300 mV compared with bare PGE. These results indicate that Poly-MB/PGE exhibits a good electrocatalytic activity toward NADH oxidation. Then, a glucose biosensor study was performed based on the determination of enzymatically generated NADH by glucose dehydrogenase (GDH) which immobilized onto Poly-MB/PGE using glutaraldehyde cross-linking procedure. The biosensing of glucose in flow injection analysis (FIA) system was performed at GDH/Poly-MB/PGE for the first time. The electrocatalytic oxidation currents of enzymatically produced NADH obtained from FI amperometric current-time curves recorded at + 200 mV and in phosphate buffer solution at pH 7.0 containing 1.0 M KCl were linearly related to the concentration of glucose. Linear calibration plots are obtained in the concentration range from 0.01 to 1.0 mM. The limit of detection (LOD) was found to be 4.0 mu M. A fast, sensitive, low-cost and disposable glucose biosensor was constructed in FIA system using GDH/Poly-MB/PGE; therefore, it might provide a new perspective for the fabrication of biosensor of other compounds such as glutamate, lactate and alcohol.
引用
收藏
页码:1355 / 1363
页数:9
相关论文
共 39 条
[21]   Amperometric biosensors based on NAD(P)-dependent dehydrogenase enzymes [J].
Lobo, MJ ;
Miranda, AJ ;
Tunon, P .
ELECTROANALYSIS, 1997, 9 (03) :191-202
[22]   Recent Developments in Electrochemical Sensors for the Detection of Neurotransmitters for Applications in Biomedicine [J].
Oezel, Rifat Emrah ;
Hayat, Akhtar ;
Andreescu, Silvana .
ANALYTICAL LETTERS, 2015, 48 (07) :1044-1069
[23]   Detection of Parathyroid Hormone Using an Electrochemical Impedance Biosensor Based on PAMAM Dendrimers [J].
Ozcan, Hakki Mevlut ;
Sezginturk, Mustafa Kemal .
BIOTECHNOLOGY PROGRESS, 2015, 31 (03) :815-822
[24]   Mechanistic studies of the electrocatalytic oxidation of NADH and ascorbate at glassy carbon electrodes modified with electrodeposited films derived from 3,4-dihydroxybenzaldehyde [J].
Pariente, F ;
Tobalina, F ;
Moreno, G ;
Hernandez, L ;
Lorenzo, E ;
Abruna, HD .
ANALYTICAL CHEMISTRY, 1997, 69 (19) :4065-4075
[25]   Methylene Blue/Multiwall Carbon Nanotube Modified Electrode for the Amperometric Determination of Hydrogen Peroxide [J].
Pena, Roselyn C. ;
Bertotti, Mauro ;
Brett, Christopher M. A. .
ELECTROANALYSIS, 2011, 23 (10) :2290-2296
[26]   A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose [J].
Piano, M. ;
Serban, S. ;
Biddle, N. ;
Pittson, R. ;
Drago, G. A. ;
Hart, J. P. .
ANALYTICAL BIOCHEMISTRY, 2010, 396 (02) :269-274
[27]  
Prodromidis MI, 2002, ELECTROANAL, V14, P241
[28]   Electrochemical biosensors [J].
Ronkainen, Niina J. ;
Halsall, H. Brian ;
Heineman, William R. .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (05) :1747-1763
[29]   Biosensing of glucose in flow injection analysis system based on glucose oxidase-quantum dot modified pencil graphite electrode [J].
Saglam, Ozlem ;
Kizilkaya, Bayram ;
Uysal, Huseyin ;
Dilgin, Yusuf .
TALANTA, 2016, 147 :315-321
[30]   Development of a dehydrogenase-based glucose anode using a molecular assembly composed of nile blue and functionalized SWCNTs and its applications to a glucose sensor and glucose/O2 biofuel cell [J].
Saleh, Farhana S. ;
Mao, Lanqun ;
Ohsaka, Takeo .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (01) :130-135