Revision Techniques After Artificial Urinary Sphincter Failure in Men: Results From a Multicenter Study

被引:31
作者
Eswara, Jairam R.
Chan, Robert
Vetter, Joel M.
Lai, H. Henry
Boone, Timothy B.
Brandes, Steven B.
机构
[1] Washington Univ, Sch Med, Dept Surg, Div Urol, St Louis, MO 63110 USA
[2] Houston Methodist Hosp, Dept Urol, Houston, TX USA
关键词
RADICAL PROSTATECTOMY; CUFF PLACEMENT; FOLLOW-UP; OUTCOMES; IMPLANTATION; REIMPLANTATION; INCONTINENCE; CONTINENCE; EROSION; RISK;
D O I
10.1016/j.urology.2015.04.023
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To compare the results of various single-component artificial urinary sphincter (AUS) revision techniques for continued/recurrent stress urinary incontinence (SUI). Although AUS placement for male SUI has a high rate of success, revisions may be performed for mechanical failure of an isolated component or continued/recurrent SUI. MATERIALS AND METHODS From 1993 to 2012, 90 AUS revisions including urethral cuff downsizing (19), pressure-regulating balloon replacement (18), cuff repositioning (11), or tandem cuff placement (42) were performed at 2 institutions. End points included reoperation, incontinence failure, and urethral erosion. The Kruskal-Wallis test was used to compare continuous variables, and the log-rank test was used to compare Kaplan-Meier curves. RESULTS Mean age was 70.2 years, and median follow-up was 33.6 months. Median time to revision was 28.9 months. Tandem cuff placement was associated with a lower rate of incontinence failure (P = .02), whereas cuff repositioning was associated with a higher rate of incontinence failure (P = .02). An increased rate of mechanical failure was observed with cuff downsizing (P = .01). Among options for revision (1) cuff downsizing is associated with a higher rate of mechanical failure, and (2) cuff repositioning with the same size is associated with a higher rate of incontinence failure, whereas (3) tandem cuff placement is associated with a lower rate of recurrent SUI compared to other types of AUS revision. CONCLUSION Cuff repositioning is associated with an increased rate of persistent incontinence after AUS revision whereas tandem cuff placement is associated with a lower rate of recurrent or persistent incontinence. (C) 2015 Elsevier Inc.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 25 条
  • [1] USE OF A DOUBLE CUFF AMS800 URINARY SPHINCTER FOR SEVERE STRESS-INCONTINENCE
    BRITO, CG
    MULCAHY, JJ
    MITCHELL, ME
    ADAMS, MC
    [J]. JOURNAL OF UROLOGY, 1993, 149 (02) : 283 - 285
  • [2] AMS-742 SPHINCTER - UCLA EXPERIENCE
    BRUSKEWITZ, R
    RAZ, S
    SMITH, RB
    KAUFMAN, JJ
    [J]. JOURNAL OF UROLOGY, 1980, 124 (06) : 812 - 814
  • [3] Revision rate after artificial urinary sphincter implantation for incontinence after radical prostatectomy: Actuarial analysis
    Clemens, JQ
    Schuster, TG
    Konnak, JW
    McGuire, EJ
    Faerber, GJ
    [J]. JOURNAL OF UROLOGY, 2001, 166 (04) : 1372 - 1375
  • [4] Tandem cuff artificial urinary sphincter as a salvage procedure following failed primary sphincter placement for the treatment of post-prostatectomy incontinence
    DiMarco, DS
    Elliott, DS
    [J]. JOURNAL OF UROLOGY, 2003, 170 (04) : 1252 - 1254
  • [5] Mayo Clinic long-term analysis of the functional durability of the AMS 800 artificial urinary sphincter: A review of 323 cases
    Elliott, DS
    Barrett, DM
    [J]. JOURNAL OF UROLOGY, 1998, 159 (04) : 1206 - 1208
  • [6] Success of de novo reimplantation of the artificial genitourinary sphincter
    Frank, I
    Elliott, DS
    Barrett, DM
    [J]. JOURNAL OF UROLOGY, 2000, 163 (06) : 1702 - 1703
  • [7] The fate of the 'modern' artificial urinary sphincter with a follow-up of more than 10 years
    Fulford, SCV
    Sutton, C
    Bales, G
    Hickling, M
    Stephenson, TP
    [J]. BRITISH JOURNAL OF UROLOGY, 1997, 79 (05): : 713 - 716
  • [8] Transcorporal artificial urinary sphincter cuff placement in cases requiring revision for erosion and urethral atrophy
    Guralnick, ML
    Miller, E
    Toh, KL
    Webster, GD
    [J]. JOURNAL OF UROLOGY, 2002, 167 (05) : 2075 - 2078
  • [9] Quality of life and continence assessment of the artificial urinary sphincter in men with minimum 3.5 years of followup
    Haab, F
    Trockman, BA
    Zimmern, PE
    Leach, GE
    [J]. JOURNAL OF UROLOGY, 1997, 158 (02) : 435 - 439
  • [10] Impact of 3.5 cm Artificial Urinary Sphincter Cuff on Primary and Revision Surgery for Male Stress Urinary Incontinence