Accuracy of Noninvasive Glucose Sensing Based on Near-Infrared Spectroscopy

被引:56
|
作者
Liu, Jin [1 ]
Liu, Rong [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Noninvasive sensing; Near-infrared spectroscopy; NIR; Reference measurement; Transmission; Diffuse reflectance; Blood glucose; TEMPERATURE; PREDICTION; LENGTH;
D O I
10.1366/14-07728
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The noninvasive sensing of the blood glucose concentration is usually based on optical, electrical, or acoustical signals induced by blood glucose; these signals are extremely weak and subject to fluctuations caused by the variation in the body or surroundings. Therefore, it is challenging to detect blood glucose noninvasively with high accuracy, and no successful accurate and noninvasive clinical application has been reported. We found that there are two key measurement issues to be addressed: systematic errors, such as the errors induced by the drifts of devices or by variations in body temperature, among others, are too large to guarantee the trueness of measurement at present; and random disturbances in repeated tests, such as disturbances associated with variations in the human-machine interface, pulses, and the thermal noise of the devices, cause larger repeated measurement errors and compromise precision. Recent novel reference measurements based on differential near-infrared (NIR) spectroscopy are considered promising for solving the systematic error issue by establishing matched references, collected at another detection site or at another time, and subsequently differencing to remove the common systematic errors. However, differencing weakens the signal of interest itself and enlarges the effects of the second issue, random disturbances affecting the precision. It is understood that only reference measurements that can meet the precision requirement will be promising for future applications. Therefore, this study quantitatively evaluates the precision of the main differential NIR spectroscopy measurements considering similar conditions and minimized random disturbances. The precision of the measurements under these conditions should represent their optimal precision levels. After the evaluation, noninvasive glucose-sensing methods that hold promise for future clinical application are proposed. Finally, the evaluation criteria could be a reference for the noninvasive detection of other physiological components.
引用
收藏
页码:1313 / 1318
页数:6
相关论文
共 50 条
  • [31] Preliminary Clinical Validation of a Differential Correction Method for Improving Measurement Accuracy in Noninvasive Measurement of Blood Glucose Using Near-Infrared Spectroscopy
    Han, Guang
    Yu, Xuyao
    Xia, Dandan
    Liu, Rong
    Liu, Jin
    Xu, Kexin
    APPLIED SPECTROSCOPY, 2017, 71 (09) : 2177 - 2186
  • [32] In Vivo Near-Infrared Noninvasive Glucose Measurement and Detection in Humans
    Han, Tongshuai
    Liu, Jin
    Liu, Rong
    Chen, Wenliang
    Yao, Mingfei
    Liu, Xueyu
    Ge, Qing
    Zhang, Zengfu
    Li, Chenxi
    Wang, Yuxiang
    Zhao, Picheng
    Sun, Di
    Xu, Kexin
    APPLIED SPECTROSCOPY, 2022, 76 (09) : 1100 - 1111
  • [33] A Noninvasive Blood Glucose Measurement System by Arduino and Near-infrared
    Zheng, Tuhong
    Li, Weixi
    Liu, Yuwei
    Ling, Bingo Wing-Kuen
    2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-CHINA (ICCE-CHINA), 2016,
  • [34] Research on the background correction in the non-invasive sensing of glucose by near-infrared spectroscopy
    Liu Rong
    Gu Xiao-yu
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1772 - 1775
  • [35] Feasibility of Noninvasive Near-Infrared Spectroscopy to Diagnose Detrusor Overactivity
    Farag, Fawzy F.
    Martens, Frank M.
    Feitz, Wout F.
    Heesakkers, John P.
    UROLOGIA INTERNATIONALIS, 2011, 87 (03) : 330 - 335
  • [36] Noninvasive Measurement of Serum Bilirubin Employing Near-Infrared Spectroscopy
    Li Gang
    Li Zhe
    Wang Meng-Jun
    Lin Ling
    Zhang Bao-Ju
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (02) : 263 - 267
  • [37] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [38] An optimized non-invasive glucose sensing based on scattering and absorption separating using near-infrared spectroscopy
    Han, Tongshuai
    Liu, Xueyu
    Liu, Jin
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING XIX: TOWARD POINT-OF-CARE DIAGNOSTICS, 2019, 10885
  • [39] Random Forest Analysis of Combined Millimeter-Wave and Near-Infrared Sensing for Noninvasive Glucose Detection
    Sun, Yuyang
    Cano-Garcia, Helena
    Kallos, Efthymios
    O'Brien, Fergus
    Akintonde, Adeyemi
    Motei, Diana-Elena
    Ancu, Oana
    Mackenzie, Richard William Alexander
    Kosmas, Panagiotis
    IEEE SENSORS JOURNAL, 2023, 23 (17) : 20294 - 20309
  • [40] Noninvasive blood glucose measurement system based on three wavelengths in near-infrared region
    Chen, Yaqin
    Bai, Ge
    Xiao, Jun
    Wang, Long
    Luo, Qingming
    FIFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2007, 6534