Accuracy of Noninvasive Glucose Sensing Based on Near-Infrared Spectroscopy

被引:56
|
作者
Liu, Jin [1 ]
Liu, Rong [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Noninvasive sensing; Near-infrared spectroscopy; NIR; Reference measurement; Transmission; Diffuse reflectance; Blood glucose; TEMPERATURE; PREDICTION; LENGTH;
D O I
10.1366/14-07728
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The noninvasive sensing of the blood glucose concentration is usually based on optical, electrical, or acoustical signals induced by blood glucose; these signals are extremely weak and subject to fluctuations caused by the variation in the body or surroundings. Therefore, it is challenging to detect blood glucose noninvasively with high accuracy, and no successful accurate and noninvasive clinical application has been reported. We found that there are two key measurement issues to be addressed: systematic errors, such as the errors induced by the drifts of devices or by variations in body temperature, among others, are too large to guarantee the trueness of measurement at present; and random disturbances in repeated tests, such as disturbances associated with variations in the human-machine interface, pulses, and the thermal noise of the devices, cause larger repeated measurement errors and compromise precision. Recent novel reference measurements based on differential near-infrared (NIR) spectroscopy are considered promising for solving the systematic error issue by establishing matched references, collected at another detection site or at another time, and subsequently differencing to remove the common systematic errors. However, differencing weakens the signal of interest itself and enlarges the effects of the second issue, random disturbances affecting the precision. It is understood that only reference measurements that can meet the precision requirement will be promising for future applications. Therefore, this study quantitatively evaluates the precision of the main differential NIR spectroscopy measurements considering similar conditions and minimized random disturbances. The precision of the measurements under these conditions should represent their optimal precision levels. After the evaluation, noninvasive glucose-sensing methods that hold promise for future clinical application are proposed. Finally, the evaluation criteria could be a reference for the noninvasive detection of other physiological components.
引用
收藏
页码:1313 / 1318
页数:6
相关论文
共 50 条
  • [21] Principal Component Analysis and Near-Infrared Spectroscopy as Noninvasive Blood Glucose Assay Methods
    Barati, Hadi
    Madani, Arian Mousavi
    Shadzinavaz, Sorena
    Fardmanesh, Mehdi
    APPLIED SPECTROSCOPY, 2024,
  • [22] In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
    Maruo, K
    Tsurugi, M
    Tamura, M
    Ozaki, Y
    APPLIED SPECTROSCOPY, 2003, 57 (10) : 1236 - 1244
  • [23] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Shiping
    Huang, Furong
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2007, 1 (06): : 307 - 311
  • [24] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Ship-Ing
    Huang, Fu-Rong
    Chen, Zhe
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (03): : 592 - 596
  • [25] Research on the Effective Signal Extraction in the Noninvasive Blood Glucose Sensing by Near Infrared Spectroscopy
    Ding Hai-quan
    Lu Qi-peng
    Wang Dong-min
    Chen Xing-dan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (01) : 50 - 53
  • [26] Near-infrared reflectance spectroscopy for noninvasive monitoring of metabolites
    Heise, HM
    Bittner, A
    Marbach, R
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (02) : 137 - 145
  • [27] NEAR-INFRARED SPECTROSCOPY - NONINVASIVE MONITORING OF CEREBRAL HEMODYNAMICS
    FAHNENSTICH, H
    KLINISCHE PADIATRIE, 1993, 205 (06): : 398 - 403
  • [28] Noninvasive Monitoring of Placental Oxygenation by Near-Infrared Spectroscopy
    Kakogawa, Jun
    Sumimoto, Kazuhiro
    Kawamura, Takakazu
    Minoura, Shigeki
    Kanayama, Naohiro
    AMERICAN JOURNAL OF PERINATOLOGY, 2010, 27 (06) : 463 - 468
  • [29] Noninvasive Human Triglyceride Detecting with Near-Infrared Spectroscopy
    Yuan Jing-ze
    Lu Qi-peng
    Wu Chun-yang
    Ding Hai-quan
    Gao Hong-zhi
    Li Wan-xia
    Wang Yang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (01) : 42 - 48
  • [30] Application of Permutation Entropy in Feature Extraction for Near-Infrared Spectroscopy Noninvasive Blood Glucose Detection
    Li, Xiaoli
    Li, Chengwei
    JOURNAL OF SPECTROSCOPY, 2017, 2017