The noninvasive sensing of the blood glucose concentration is usually based on optical, electrical, or acoustical signals induced by blood glucose; these signals are extremely weak and subject to fluctuations caused by the variation in the body or surroundings. Therefore, it is challenging to detect blood glucose noninvasively with high accuracy, and no successful accurate and noninvasive clinical application has been reported. We found that there are two key measurement issues to be addressed: systematic errors, such as the errors induced by the drifts of devices or by variations in body temperature, among others, are too large to guarantee the trueness of measurement at present; and random disturbances in repeated tests, such as disturbances associated with variations in the human-machine interface, pulses, and the thermal noise of the devices, cause larger repeated measurement errors and compromise precision. Recent novel reference measurements based on differential near-infrared (NIR) spectroscopy are considered promising for solving the systematic error issue by establishing matched references, collected at another detection site or at another time, and subsequently differencing to remove the common systematic errors. However, differencing weakens the signal of interest itself and enlarges the effects of the second issue, random disturbances affecting the precision. It is understood that only reference measurements that can meet the precision requirement will be promising for future applications. Therefore, this study quantitatively evaluates the precision of the main differential NIR spectroscopy measurements considering similar conditions and minimized random disturbances. The precision of the measurements under these conditions should represent their optimal precision levels. After the evaluation, noninvasive glucose-sensing methods that hold promise for future clinical application are proposed. Finally, the evaluation criteria could be a reference for the noninvasive detection of other physiological components.
引用
收藏
页码:1313 / 1318
页数:6
相关论文
共 50 条
  • [1] Noninvasive blood glucose sensing with near-infrared spectroscopy based on interstitial fluid
    Lu, Q. (luqipeng@126.com), 1600, Chinese Optical Society (33):
  • [2] NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY
    HEISE, HM
    MARBACH, R
    KOSCHINSKY, T
    GRIES, FA
    ARTIFICIAL ORGANS, 1994, 18 (06) : 439 - 447
  • [3] Noninvasive Blood Glucose Analysis Based on Near-Infrared Reflectance Spectroscopy
    Lu Xiao-feng
    Zhang Ting-lin
    Xiao Feng
    Li Guang
    Wang You
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (07) : 2312 - 2317
  • [4] Evaluation of measurement sites for noninvasive blood glucose sensing with near-infrared transmission spectroscopy
    Burmeister, JJ
    Arnold, MA
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1621 - 1627
  • [5] The influence of experiment design on the model precision in the noninvasive glucose sensing by near-infrared spectroscopy
    Liu, Rong
    Chen, Wenliang
    Xu, Kexin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS III, 2008, 6826 : U426 - U435
  • [6] On Feasibility of Near-Infrared Spectroscopy for Noninvasive Blood Glucose Measurements
    Vural, N. Mert
    Yoleri, Yigit
    Torun, Hamdi
    OPTICAL DIAGNOSTICS AND SENSING XIX: TOWARD POINT-OF-CARE DIAGNOSTICS, 2019, 10885
  • [7] Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy
    Malin, SF
    Ruchti, TL
    Blank, TB
    Thennadil, SN
    Monfre, SL
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1651 - 1658
  • [8] INTERFERING SUBSTANCES FOR GLUCOSE SENSING BY NEAR-INFRARED SPECTROSCOPY
    Fuglerud, S.
    Ellingsen, R.
    Aksnes, A.
    Hjelme, D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A115 - A115
  • [9] Monte Carlo simulation-based thinning and calculating method for noninvasive blood glucose sensing by near-infrared spectroscopy
    Ma, Congcong
    Qin, Jia
    Zhang, Qi
    Lu, Junsheng
    Xu, Kexin
    Jiang, Jingying
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (02)
  • [10] Noninvasive blood glucose sensing by near-infrared spectroscopy based on PLSR combines SAE deep neural network approach
    Han, Guang
    Chen, Siqi
    Wang, Xiaoyan
    Wang, Jinhai
    Wang, Huiquan
    Zhao, Zhe
    INFRARED PHYSICS & TECHNOLOGY, 2021, 113