Analysis and optimization of a coal-fired power plant under a proposed flue gas recirculation mode

被引:28
作者
Zhang, Guoqiang
Xu, Wenlong
Wang, Xiuyan
Yang, Yongping [1 ]
机构
[1] North China Elect Power Univ, Beijing 102206, Peoples R China
基金
美国国家科学基金会;
关键词
Flue gas recirculation; New location of flue gas extraction; Sensitivity analysis; Optimization; COMBUSTION;
D O I
10.1016/j.enconman.2015.01.073
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study mainly investigated the influence of flue gas recirculation (FGR) on reheat steam temperature, boiler efficiency, and thermal efficiency in a proposed FGR scheme. The main parameters of the boiler are calculated under different modes on the basis of a 600 MW coal-fired boiler. Optimization is conducted, and the optimum recirculation rate and coal input are determined. Results from case study showed that under the same recirculation rate, the reheat temperature increases higher and the net coal consumption decreases more in the improved recirculation system than those in the traditional recirculation system. The key parameters, such as the FGR rate and coal feed rate are optimized. Under optimum recirculation rate and coal input conditions, the net coal consumption rate can be reduced by 2.35-2.60 g/(kW h) compared with that obtained with the use of a conventional recirculation system. This net coal consumption rate can be reduced by 3.50-5.11 g/(kW h) compared with that obtained without gas recirculation system. For a better operation, lower recirculation rate and relative higher coal input are recommended under high-load conditions, whereas higher recirculation rate and relative lower coal input are appropriate for low-load conditions. (c) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 18 条
[1]  
An LS, 2009, PUMPS AND FANS
[2]   Flue gas recirculation in a gas-fired laboratory furnace: Measurements and modelling [J].
Baltasar, J ;
Carvalho, MG ;
Coelho, P ;
Costa, M .
FUEL, 1997, 76 (10) :919-929
[3]   Effect of air ingress on the energy performance of coal fired thermal power plants [J].
Bhatt, M. Siddhartha .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (07) :2150-2160
[4]  
Blasiak W., 2013, INT J CLEAN COAL ENE, V02, P13, DOI DOI 10.4236/IJCCE.2013.22002
[5]   Effects of temperature and flue gas recycle on the SO2 and NOx emissions in an oxy-fuel fluidized bed combustor [J].
de las Obras-Loscertales, M. ;
Rufas, A. ;
de Diego, L. F. ;
Garcia-Labiano, F. ;
Gayan, P. ;
Abad, A. ;
Adanez, J. .
GHGT-11, 2013, 37 :1275-1282
[6]  
Fan Q., 2008, BOILER PRINCIPLE
[7]   Effects of coal properties on recycled-NOx reduction in coal combustion with O2/recycled flue gas [J].
Hu, YQ ;
Kobayashi, N ;
Hasatani, M .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (14) :2331-2340
[8]   Effects of flue gas recycle on oxy-coal power generation systems [J].
Hu, Yukun ;
Yan, Jinyue ;
Li, Hailong .
APPLIED ENERGY, 2012, 97 :255-263
[9]  
Jiang ZS, 1973, BOILER TECHNOL, V12, P2
[10]  
Li Daolin, 2001, BOILER TECHNOL, V15, P2