Multi-energy performance of a research prototype CT scanner with small-pixel counting detector

被引:22
作者
Kappler, S. [1 ]
Henning, A. [1 ]
Krauss, B. [1 ]
Schoeck, F. [1 ]
Stierstorfer, K. [1 ]
Weidinger, T. [1 ]
Flohr, T. [1 ]
机构
[1] Siemens Healthcare, D-91301 Forchheim, Germany
来源
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING | 2013年 / 8668卷
关键词
CT; dual-energy CT; spectral CT; photon counting;
D O I
10.1117/12.2006747
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have investigated the multi-energy performance of our most recent prototype CT scanner with CdTe-based counting detector. With its small pixel pitch of 225 mu m this device is prepared for the high X-ray fluxes occurring in clinical CT. Each of these pixels is equipped with two adjustable counters. The ASIC architecture of the detector allows configuration of the counter thresholds in chess patterns, enabling data acquisition in up to four energy bins. We have studied the material separation capability of counting CT with respect to potential clinical applications. Therefore we have analyzed contrast and noise properties in material decomposed CT images using up to four base materials. We have studied contrast agents containing iodine, gadolinium, or gold, and the body-like materials calcium, fat, and water. We describe the mathematical framework used in this work and demonstrate the general multi-energy capability of counting CT with simulations and experimental data from our prototype scanner. To prove the clinical relevance of our studies we compare the results to those obtained with well-established dual-kVp techniques recorded at same patient dose and with identical image sharpness.
引用
收藏
页数:8
相关论文
共 9 条
[1]  
[Anonymous], 2009, SOMATOM DEFINITION F
[2]  
Firsching M., 2004, NUCL SCI S, V7
[3]  
JOHNS PC, 2002, SPEI TD, V1, P367
[4]   First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT [J].
Kappler, S. ;
Hannemann, T. ;
Kraft, E. ;
Kreisler, B. ;
Niederloehner, D. ;
Stierstorfer, K. ;
Flohr, T. .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[5]   Contrast-enhancement, image noise and dual-energy simulations for quantum-counting clinical CT [J].
Kappler, S. ;
Niederloehner, D. ;
Stierstorfer, K. ;
Flohr, T. .
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
[6]  
Lehmann L., 1986, DIGITAL RADIOGRAPHY, P14588
[7]  
Riederer S. J., 1977, MED PHYS, V4
[8]   K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors [J].
Roessl, E. ;
Proksa, R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15) :4679-4696
[9]  
Sukovic P., 1999, P 16 IEEE INSTR MEAS, V3, P16158