Cortical volume and 40-Hz auditory-steady-state responses in patients with schizophrenia and healthy controls

被引:32
作者
Kim, Sungkean [1 ,2 ]
Jang, Seon-Kyeong [1 ]
Kim, Do-Won [3 ]
Shim, Miseon [4 ]
Kim, Yong-Wook [1 ,2 ]
Im, Chang-Hwan [2 ]
Lee, Seung-Hwan [1 ,5 ]
机构
[1] Inje Univ, Clin Emot & Cognit Res Lab, Goyang, South Korea
[2] Hanyang Univ, Dept Biomed Engn, Seoul, South Korea
[3] Chonnam Natl Univ, Dept Biomed Engn, Yeosu, South Korea
[4] Univ Missouri, Dept Psychiat, Kansas City, MO 64110 USA
[5] Inje Univ, Ilsan Paik Hosp, Dept Psychiat, Goyang, South Korea
关键词
40-Hz ASSR; Gamma oscillation; STG volume; Schizophrenia; Voxel-based morphometry; GAMMA BAND OSCILLATIONS; CONFIDENCE-INTERVALS; NEURAL OSCILLATIONS; DYSFUNCTION; SYNCHRONY; STIMULATION; AMPLITUDE; DEFICITS; RANGE; ABNORMALITIES;
D O I
10.1016/j.nicl.2019.101732
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background: Abnormalities in the 40-Hz auditory steady-state response (ASSR) of the gamma range have been reported in schizophrenia (SZ) and are regarded as important pathophysiological features. Many of the previous studies reported diminished gamma oscillations in SZ, although some studies reported increased spontaneous gamma oscillations. Furthermore, brain morphological correlates of the gamma band ASSR deficits have rarely examined. We investigated different measures of the 40-Hz ASSR and their association with brain volumes and psychological measures of SZ. Methods: The 40-Hz ASSR was measured for 80 dB click sounds (1 ms, 500-ms trains at 40-Hz, with 3050 to 3500 inter-train interval) using electroencephalography with 64 electrodes in 33 patients with SZ (male: 16, female: 17 (age range: 21-60)) and 30 healthy controls (HCs) (male: 13, female: 17 (age range: 23-64)). Four gamma oscillation measures (evoked power, spontaneous oscillations (baseline and total power), and inter-trial phase coherence (ITC)) were assessed. The source activities of the ASSR were also analyzed. Brain volumes were assessed using high-resolution magnetic resonance imaging and voxel-based morphometry and superior temporal gyrus (STG) volume measures were obtained. Results: Patients with SZ had larger total and evoked powers and higher ITC than HCs. Both groups showed significantly different association between mean evoked power and right STG volume. In HCs but not SZ, mean evoked power showed significant positive correlation with right STG volume. In addition, the two groups showed significantly different association between verbal fluency and mean evoked power. High evoked power was significantly correlated with poor verbal fluency in SZ. Conclusions: The current study found increased gamma oscillation in SZ and suggests significant involvement of the STG in gamma oscillations.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] The beta component of gamma-band auditory steady-state responses in patients with schizophrenia
    Metzner, Christoph
    Steuber, Volker
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [42] Binaural Interaction Effects of 30-50 Hz Auditory Steady State Responses
    Gransier, Robin
    van Wieringen, Astrid
    Wouters, Jan
    EAR AND HEARING, 2017, 38 (05) : E305 - E315
  • [43] Auditory steady state responses in a schizophrenia rat model probed by excitatory/inhibitory receptor manipulation
    Vohs, Jenifer L.
    Chambers, R. Andrew
    O'Donnell, Brian F.
    Krishnan, Giri P.
    Morzorati, Sandra L.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 86 (02) : 136 - 142
  • [44] Augmented gamma band auditory steady-state responses: Support for NMDA hypofunction in schizophrenia
    Hamm, Jordan P.
    Gilmore, Casey S.
    Clementz, Brett A.
    SCHIZOPHRENIA RESEARCH, 2012, 138 (01) : 1 - 7
  • [45] Abnormal phase entrainment of low- and high-gamma-band auditory steady-state responses in schizophrenia
    Nakanishi, Shoichiro
    Tamura, Shunsuke
    Hirano, Shogo
    Takahashi, Junichi
    Kitajima, Kazutoshi
    Takai, Yoshifumi
    Mitsudo, Takako
    Togao, Osamu
    Nakao, Tomohiro
    Onitsuka, Toshiaki
    Hirano, Yoji
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [46] MEG and EEG demonstrate similar test-retest reliability of the 40 Hz auditory steady-state response
    Legget, Kristina T.
    Hild, Allison K.
    Steinmetz, Sarah E.
    Simon, Steven T.
    Rojas, Donald C.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2017, 114 : 16 - 23
  • [47] Source decomposition of the frontocentral auditory steady-state gamma band response in schizophrenia patients and healthy subjects
    Koshiyama, Daisuke
    Miyakoshi, Makoto
    Joshi, Yash B.
    Nakanishi, Masaki
    Tanaka-Koshiyama, Kumiko
    Sprock, Joyce
    Light, Gregory A.
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 2021, 75 (05) : 172 - 179
  • [48] Deficits in the 30-Hz auditory steady-state response in patients with major depressive disorder
    Chen, Jingjing
    Gong, Qin
    Wu, Fei
    NEUROREPORT, 2016, 27 (15) : 1147 - 1152
  • [49] By our bootstraps: Comparing methods for measuring auditory 40 Hz steady-state neural activity
    Edgar, J. Christopher
    Fisk, Charles L.
    Chen, Yu-Han
    Stone-Howell, Breannan
    Hunter, Michael A.
    Huang, Mingxiong
    Bustillo, Juan R.
    Canive, Jose M.
    Miller, Gregory A.
    PSYCHOPHYSIOLOGY, 2017, 54 (08) : 1110 - 1127
  • [50] Auditory steady-state response at 20 Hz and 40 Hz in young typically developing children and children with autism spectrum disorder
    Ono, Yasuki
    Kudoh, Kiwamu
    Ikeda, Takashi
    Takahashi, Tetsuya
    Yoshimura, Yuko
    Minabe, Yoshio
    Kikuchi, Mitsuru
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 2020, 74 (06) : 354 - 361