摘要
Equal channel angular pressing method is one of the prominent severe plastic deformation techniques to obtain ultrafine grained and even nanostructured metals and alloys by imposing intense plastic strain. As known, pure titanium can be a suitable candidate for biomedical applications because it does not release any toxic ions into the body fluids and also, its biocompatibility properties. The present investigation deals the corrosion behavior of commercial pure titanium before and after ECAP process up to 10 passes by route BC at the 250 degrees C in the 0.9% NaCl solution. The electrochemical results revealed that the corrosion resistance of titanium sample is improved by adding pass number because of the fabrication of passive oxide layer on the surface of the material. It is found that about 92% reduction at the corrosion rate magnitude and also, approximately 41% improvement at the hardness value have been achieved at the final pass as compared to the annealed condition. Furthermore, it is observed that the passive film on the surface of final pass sample is dense and integral with uniform structure, while the as-received one has some rarefactions and does not have very uniform surface.
引用
收藏
页数:9
相关论文
共 19 条
[1]  
Balakrishnan A., 2008, TRENDS BIOMATERIALS, V22, P58
[2]   Corrosion resistance of ultra fine-grained Ti [J].
Balyanov, A ;
Kutnyakova, J ;
Amirkhanova, NA ;
Stolyarov, VV ;
Valiev, RZ ;
Liao, XZ ;
Zhao, YH ;
Jiang, YB ;
Xu, HF ;
Lowe, TC ;
Zhu, YT .
SCRIPTA MATERIALIA, 2004, 51 (03) :225-229
[3]   Ti based biomaterials, the ultimate choice for orthopaedic implants - A review [J].
Geetha, M. ;
Singh, A. K. ;
Asokamani, R. ;
Gogia, A. K. .
PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) :397-425
[4]   Ultra-fine grained bulk CP-Ti processed by multi-pass ECAP a warm deformation region [J].
Hajizadeh, K. ;
Eghbali, B. ;
Topolski, K. ;
Kurzydlowski, K. J. .
MATERIALS CHEMISTRY AND PHYSICS, 2014, 143 (03) :1032-1038
[5]   Comparative effect of grain size and texture on the corrosion behaviour of commercially pure titanium processed by equal channel angular pressing [J].
Hoseini, Majid ;
Shahryari, Arash ;
Omanovic, Sasha ;
Szpunar, Jerzy A. .
CORROSION SCIENCE, 2009, 51 (12) :3064-3067
[6]   Structure and mechanical and electrochemical properties of ultrafine-grained Ti [J].
Kolobov Yu.R. ;
Kashin O.A. ;
Sagymbaev E.E. ;
Dudarev E.F. ;
Bushnev L.S. ;
Grabovetskaya G.P. ;
Pochivalova G.P. ;
Girsova N.V. ;
Stolarov V.V. .
Russian Physics Journal, 2000, 43 (1) :71-78
[7]   Corrosion of ultra-fine grained copper fabricated by equal-channel angular pressing [J].
Miyamoto, Hiroyuki ;
Harada, Kohei ;
Mimaki, Takuro ;
Vinogradov, Alexei ;
Hashimoto, Satoshi .
CORROSION SCIENCE, 2008, 50 (05) :1215-1220
[8]   AFM and SEM characterization of non-toxic vanadium-free Ti alloys used as biomaterials [J].
Morant, C ;
López, MF ;
Gutiérrez, A ;
Jiménez, JA .
APPLIED SURFACE SCIENCE, 2003, 220 (1-4) :79-87
[9]   Effect of Grain Size on Corrosion: A Review [J].
Ralston, K. D. ;
Birbilis, N. .
CORROSION, 2010, 66 (07) :0750051-07500513
[10]   Ultra-fine grained bulk aluminum produced by accumulative roll-bonding (ARB) process [J].
Saito, Y ;
Tsuji, N ;
Utsunomiya, H ;
Sakai, T ;
Hong, RG .
SCRIPTA MATERIALIA, 1998, 39 (09) :1221-1227