Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program

被引:142
作者
Console, J. W. [1 ,2 ]
Sakata, L. M. [3 ,4 ]
Aung, T. [3 ,4 ]
Friedman, D. S. [5 ]
He, M. [1 ]
机构
[1] Zhongshan Ophthalm Ctr, Guangzhou 510060, Guangdong, Peoples R China
[2] Univ Kansas, Sch Med, Kansas City, KS USA
[3] Singapore Eye Res Inst, Singapore, Singapore
[4] Singapore Natl Eye Ctr, Singapore, Singapore
[5] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, MD 21218 USA
关键词
D O I
10.1136/bjo.2007.129932
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To describe a new image analysis method and software for anterior chamber images obtained by the anterior-segment optical coherence tomography (AS-OCT) and to assess its intraobserver and interobserver measurement reproducibility. Methods: Twenty 8-bit greyscale 6006300 AS-OCT images with apparent wide angles and 20 images with apparent narrow angles were consecutively selected from a database. Two glaucoma fellowship-trained ophthalmologists used proprietary image analysis software to analyse the images twice. Algorithms defined the borders and curvatures of anterior chamber (AC) structures and measured AC parameters using scleral spur location as the only observer input. The intraobserver and interobserver reproducibility of scleral spur location and angle parameters was calculated in terms of limits of agreement (LOA; mean of differences +/- 1.96SD of differences) and coefficient of variation (CV; SD of differences/overall mean). Results: The analysis software successfully measured all parameters in all images. When the same image was assessed twice by the same grader, the mean differences ranged from 0 to 0.010 mm in linear measurements and 0.001 to 0.006 mm(2) in angle area measurements. LOA tended to be greater in the wider angles. The upper and lower limit values of LOAs were approximately 1/5 to 1/4 of the overall mean. Measurements between two graders had a higher variance. Reproducibility in terms of CV was better in wide angles when compared with narrow angles. The reproducibility of scleral spur placement between observers was poorer in narrow angles (p= 0.001). About 50% of the interobserver variance in angle-area measurements was attributable to the variance of scleral spur placement, while this proportion was only 10-20% in linear measurements. Conclusions: Determination of angle parameters using semiautomated software leads to variability in measurement. Variability increases when more than one observer identifies the scleral spur. Variability differs in narrow and open angles, and so including both types is essential when evaluating angle-assessment software. A fully automated analysis and higher image resolution would likely improve quantification of Visante AS-OCT images.
引用
收藏
页码:1612 / 1616
页数:5
相关论文
共 13 条
  • [1] Measurement error
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 312 (7047) : 1654 - 1654
  • [2] Ultrasound biomicroscopy dark room provocative testing: A quantitative method for estimating anterior chamber angle width
    Ishikawa, H
    Esaki, K
    Liebmann, JM
    Uji, Y
    Ritch, R
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 1999, 43 (06) : 526 - 534
  • [3] Novel approach for anterior chamber angle analysis - Anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA)
    Leung, Christopher Kai-shun
    Yung, Wing-ho
    Yiu, Cedric Ka-fai
    Lam, Sze-wing
    Leung, Dexter Yu-lung
    Tse, Raymond Kwok-kay
    Tham, Clement Chi-yung
    Chan, Wai-man
    Lam, Dennis Shun-chiu
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (10) : 1395 - 1401
  • [4] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [5] Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability
    Mueller, Maya
    Dahmen, Gerlinde
    Poerksen, Erk
    Geerling, Gerd
    Laqua, Horst
    Ziegler, Andreas
    Hoerauf, Hans
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1803 - 1808
  • [6] Detection of narrow angles and established angle closure in Chinese residents of Singapore: Potential screening tests
    Nolan, Winifred P.
    Aung, Tin
    Machin, David
    Khaw, Peng T.
    Johnson, Gordon J.
    Seah, Steve K. L.
    Foster, Paul J.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 896 - 901
  • [7] ULTRASOUND BIOMICROSCOPY OF ANTERIOR SEGMENT STRUCTURES IN NORMAL AND GLAUCOMATOUS EYES
    PAVLIN, CJ
    HARASIEWICZ, K
    FOSTER, FS
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) : 381 - 389
  • [8] Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    Radhakrishnan, S
    Goldsmith, J
    Huang, D
    Westphal, V
    Dueker, DK
    Rollins, AM
    Izatt, JA
    Smith, SD
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) : 1053 - 1059
  • [9] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [10] Radhakrishnan Sunita, 2005, Ophthalmol Clin North Am, V18, P375, DOI 10.1016/j.ohc.2005.05.007