Corrosion at the Cone/Taper Interface Leads to Failure of Large-diameter Metal-on-metal Total Hip Arthroplasties

被引:126
作者
Meyer, Heiko [1 ]
Mueller, Tina [1 ]
Goldau, Gesine [2 ]
Chamaon, Kathrin [1 ]
Ruetschi, Marcel [3 ]
Lohmann, Christoph H. [1 ]
机构
[1] Univ Magdeburg, Dept Orthopaed, D-39108 Magdeburg, Germany
[2] Univ Appl Sci, Magdeburg, Germany
[3] Loretto Hosp, Dept Orthopaed, Freiburg, Germany
关键词
WEAR PRODUCTS; ION LEVELS; REPLACEMENT; BEARINGS; DEBRIS; BLOOD; HYPERSENSITIVITY; COMPONENTS; CHROMIUM; COBALT;
D O I
10.1007/s11999-012-2502-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Metal-on-metal (MoM) THAs have reduced wear rates compared with metal-on-polyethylene. However, elevated serum metal ion levels and pseudotumors have been reported in large MoM articulations. Questions/purposes We therefore determined (1) if corrosion occurred at the cone/taper interface leading to instability in patients with large-diameter THAs; (2) how patients presented clinically and radiographically; (3) if adverse periprosthetic tissue reactions occurred; (4) whether metal was released from the implants into the periprosthetic tissues; and (5) if head size correlated with metal release. Methods We reviewed 114 patients who had revisions of large-diameter head MoM articulations. Mean time of implantation was 46 months. To identify adverse reactions and particle load, tissues were stained by hematoxylin and eosin and CD3/CD20/CD68 antibodies. Periprosthetic tissues were analyzed for metal content and distribution in different regions. Electrochemical reactions between the stem and adapter were investigated by a minicell electrode. Results Electrochemical studies on the stem and the head adapter showed a risk for galvanic corrosion. Ninety-four percent of patients had instability at the cone/taper interface. All patients presented with early clinical symptoms; 59 patients had radiographic signs of loosening. One hundred four patients had foreign body reactions and necrosis. The largest amounts of metal released were titanium or iron. We found no correlation between head size and metal ion release. Conclusions These findings suggest that in modular cone/taper connections, friction of the MoM articulations may cause failure of the cone/taper interface leading to galvanic corrosion and loosening. It is unclear whether the design of this MoM system provides sufficient stability at the taper.
引用
收藏
页码:3101 / 3108
页数:8
相关论文
共 50 条
[41]   Modes of Failure in Metal-on-Metal Total Hip Arthroplasty [J].
Fehring, Keith A. ;
Fehring, Thomas K. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (02) :185-+
[42]   Metal-on-metal bearings in total hip arthroplasties: Influence of cobalt chromium ions on bacterial growth and biofilm formation [J].
Hosman, Anton H. ;
van der Mei, Henny C. ;
Bulstra, Sjoerd K. ;
Busscher, Henk J. ;
Neut, Danielle .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 88A (03) :711-716
[43]   Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings [J].
Bishop, Nicholas ;
Witt, Florian ;
Pourzal, Robin ;
Fischer, Alfons ;
Ruetschi, Marcel ;
Michel, Markus ;
Morlock, Michael .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (07) :1116-1122
[44]   Surgical Approach May Influence Survival of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty: A 6-to 10-Year Follow-Up Study [J].
Hu, Chih-Chien ;
Huang, Tsan-Wen ;
Lin, Shih-Jie ;
Lin, Po-Chun ;
Kuo, Feng-Chih ;
Peng, Kuo-Ti ;
Huang, Kuo-Chin ;
Shih, Hsin-Nung ;
Lee, Mel S. .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[45]   The Long-Term Survivorship and Cause of Failure of Metal-on-Metal Total Hip Arthroplasty [J].
Wakabayashi, Hiroki ;
Hasegawa, Masahiro ;
Naito, Yohei ;
Tone, Shine ;
Sudo, Akihiro .
ANTIBIOTICS-BASEL, 2025, 14 (02)
[46]   What Are the Predictors and Prevalence of Pseudotumor and Elevated Metal Ions After Large-diameter Metal-on-metal THA? [J].
Bayley, Nick ;
Khan, Habeeb ;
Grosso, Paul ;
Hupel, Thomas ;
Stevens, David ;
Snider, Matthew ;
Schemitsch, Emil ;
Kuzyk, Paul .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) :477-484
[47]   Comparison of the long-term cause of failure and survivorship of four hundred and twenty seven metal-on-metal hip arthroplasties: resurfacing versus large head total hip arthroplasty [J].
Palazzuolo, Michele ;
Antoniadis, Alexander ;
Delaune, Leilani ;
Tornare, Ines ;
Wegrzyn, Julien .
INTERNATIONAL ORTHOPAEDICS, 2021, 45 (12) :3075-3081
[48]   The Relation Between Titanium Taper Corrosion and Cobalt-Chromium Bearing Wear in Large-Head Metal-on-Metal Total Hip Prostheses A Retrieval Study [J].
Witt, F. ;
Bosker, B. H. ;
Bishop, N. E. ;
Ettema, H. B. ;
Verheyen, C. C. P. M. ;
Morlock, M. M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (18) :e157(1)
[49]   Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements [J].
Cook, Richard B. ;
Bolland, Benjamin J. R. F. ;
Wharton, Julian A. ;
Tilley, Simon ;
Latham, Jeremy M. ;
Wood, Robert J. K. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :1430-1436
[50]   Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs [J].
Donell, S. T. ;
Darrah, C. ;
Nolan, J. F. ;
Wimhurst, J. ;
Toms, A. ;
Barker, T. H. W. ;
Case, C. P. ;
Tucker, J. K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11) :1501-1508