Corrosion at the Cone/Taper Interface Leads to Failure of Large-diameter Metal-on-metal Total Hip Arthroplasties

被引:124
作者
Meyer, Heiko [1 ]
Mueller, Tina [1 ]
Goldau, Gesine [2 ]
Chamaon, Kathrin [1 ]
Ruetschi, Marcel [3 ]
Lohmann, Christoph H. [1 ]
机构
[1] Univ Magdeburg, Dept Orthopaed, D-39108 Magdeburg, Germany
[2] Univ Appl Sci, Magdeburg, Germany
[3] Loretto Hosp, Dept Orthopaed, Freiburg, Germany
关键词
WEAR PRODUCTS; ION LEVELS; REPLACEMENT; BEARINGS; DEBRIS; BLOOD; HYPERSENSITIVITY; COMPONENTS; CHROMIUM; COBALT;
D O I
10.1007/s11999-012-2502-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Metal-on-metal (MoM) THAs have reduced wear rates compared with metal-on-polyethylene. However, elevated serum metal ion levels and pseudotumors have been reported in large MoM articulations. Questions/purposes We therefore determined (1) if corrosion occurred at the cone/taper interface leading to instability in patients with large-diameter THAs; (2) how patients presented clinically and radiographically; (3) if adverse periprosthetic tissue reactions occurred; (4) whether metal was released from the implants into the periprosthetic tissues; and (5) if head size correlated with metal release. Methods We reviewed 114 patients who had revisions of large-diameter head MoM articulations. Mean time of implantation was 46 months. To identify adverse reactions and particle load, tissues were stained by hematoxylin and eosin and CD3/CD20/CD68 antibodies. Periprosthetic tissues were analyzed for metal content and distribution in different regions. Electrochemical reactions between the stem and adapter were investigated by a minicell electrode. Results Electrochemical studies on the stem and the head adapter showed a risk for galvanic corrosion. Ninety-four percent of patients had instability at the cone/taper interface. All patients presented with early clinical symptoms; 59 patients had radiographic signs of loosening. One hundred four patients had foreign body reactions and necrosis. The largest amounts of metal released were titanium or iron. We found no correlation between head size and metal ion release. Conclusions These findings suggest that in modular cone/taper connections, friction of the MoM articulations may cause failure of the cone/taper interface leading to galvanic corrosion and loosening. It is unclear whether the design of this MoM system provides sufficient stability at the taper.
引用
收藏
页码:3101 / 3108
页数:8
相关论文
共 50 条
[21]   Primary metal-on-metal total hip arthroplasty with large-diameter femoral heads : A clinical trial of 59 hips [J].
Cicek, Hakan ;
Kilicarslan, Kasim ;
Yalcin, Nadir ;
Arslan, Erhan ;
Dogramaci, Yunus ;
Yildirim, Hasan .
ACTA ORTHOPAEDICA BELGICA, 2010, 76 (06) :758-765
[22]   Which Factors Determine the Wear Rate of Large-Diameter Metal-on-Metal Hip Replacements? [J].
Hart, A. J. ;
Muirhead-Allwood, S. ;
Porter, M. ;
Matthies, A. ;
Ilo, K. ;
Maggiore, P. ;
Underwood, R. ;
Cann, P. ;
Cobb, J. ;
Skinner, J. A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (08) :678-685
[23]   Intraoperative Complications and Mid-Term Follow-Up of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty and Hip Resurfacing Arthroplasty [J].
Miettinen, S. S. A. ;
Makinen, T. J. ;
Makela, K. ;
Huhtala, H. ;
Kettunen, J. S. ;
Remes, V. .
SCANDINAVIAN JOURNAL OF SURGERY, 2018, 107 (02) :180-186
[24]   Stability and Trunnion Wear Potential in Large-diameter Metal-on-Metal Total Hips: A Finite Element Analysis [J].
Elkins, Jacob M. ;
Callaghan, John J. ;
Brown, Thomas D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (02) :529-542
[25]   High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement A PROSPECTIVE COHORT STUDY [J].
Bosker, B. H. ;
Ettema, H. B. ;
Boomsma, M. F. ;
Kollen, B. J. ;
Maas, M. ;
Verheyen, C. C. P. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06) :755-761
[26]   Cushion bearings versus large diameter head metal-on-metal bearings in total hip arthroplasty: a short-term metal ion study [J].
Moroni, Antonio ;
Nocco, Emanuele ;
Hoque, Martha ;
Diremigio, Elena ;
Buffoli, Dario ;
Cantu, Francesco ;
Catalani, Simona ;
Apostoli, Pietro .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (01) :123-129
[27]   Repeated magnetic resonance imaging in 154 hips with large-diameter metal-on-metal hip replacement [J].
Reito, Aleksi ;
Elo, Petra ;
Puolakka, Timo ;
Pajamaki, Jorma ;
Nieminen, Jyrki ;
Eskelinen, Antti .
ACTA ORTHOPAEDICA, 2014, 85 (06) :570-576
[28]   Can a safe level for metal ions in patients with metal-on-metal total hip arthroplasties be determined? [J].
MacDonald, SJ .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :71-77
[29]   Comparison of Whole-Blood Metal Ion Levels in Four Types of Metal-on-Metal Large-Diameter Femoral Head Total Hip Arthroplasty: The Potential Influence of the Adapter Sleeve [J].
Lavigne, Martin ;
Belzile, Etienne L. ;
Roy, Alain ;
Morin, Francois ;
Amzica, Traian ;
Vendittoli, Pascal-Andre .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A :128-136
[30]   Early failures in large head metal-on-metal total hip arthroplasty [J].
Althuizen, Martje N. R. ;
Hooff, Miranda L. V. ;
Erp, Saskia H. M. V. D. Berg-v. ;
Limbeek, Jacques V. ;
Nijhof, Marc W. .
HIP INTERNATIONAL, 2012, 22 (06) :641-647