Preliminary Study on the Diagnostic Value of Acoustic Radiation Force Impulse Technology for Differentiating Between Benign and Malignant Thyroid Nodules

被引:0
|
作者
Gu, Jiying [1 ]
Du, Lianfang [1 ]
Bai, Min [1 ]
Chen, Huili [1 ]
Jia, Xiao [1 ]
Zhao, Jing [1 ]
Zhang, Xuemei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Ultrasound, Shanghai 200080, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Pathol, Shanghai 200080, Peoples R China
关键词
acoustic radiation force impulse; thyroid nodule; sonography; FINE-NEEDLE-ASPIRATION; IN-VIVO; ELASTOGRAPHY; ULTRASOUND; CANCER; US;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. Methods-Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging(VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the chi(2) test were used to compare the elastic parameters. Results-Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values +/- SD of 2.034 +/- 0.484, 1.835 +/- 0.364, 2.293 +/- 0.787, and 3.941 +/- 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). Conclusions-Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 50 条
  • [41] Diagnostic Performance of Acoustic Radiation Force Impulse Elastography for the Differentiation of Benign and Malignant Superficial Lymph Nodes: A Meta-analysis
    Li, Jun
    Chen, Ming
    Cao, Chun-li
    Zhou, Li-Qiang
    Li, Shu-Gang
    Ge, Zong-Kai
    Zhang, Wei-Hong
    Xu, Jian-Wei
    Cui, Xin-Wu
    Dietrich, Christoph F.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (02) : 213 - 222
  • [42] Diagnostic value of elastosonographically determined strain index in the differential diagnosis of benign and malignant thyroid nodules
    Cakir, Bekir
    Aydin, Cevdet
    Korukluoglu, Birol
    Ozdemir, Didem
    Sisman, I. Cagatay
    Tuzun, Dilek
    Oguz, Ayten
    Guler, Gulnur
    Guney, Guven
    Kusdemitr, Ahmet
    Sanisoglu, S. Yavuz
    Ersoy, Reyhan
    ENDOCRINE, 2011, 39 (01) : 89 - 98
  • [43] Ultrasonographic elastography of the breast using acoustic radiation force impulse technology: preliminary study
    Mitsuhiro Tozaki
    Sachiko Isobe
    Miki Yamaguchi
    Yukari Ogawa
    Kanako Homma
    Masahiro Saito
    Chanwoong Joo
    Eisuke Fukuma
    Japanese Journal of Radiology, 2011, 29 : 452 - 456
  • [44] Diagnostic efficacy of multiple MRI parameters in differentiating benign vs. malignant thyroid nodules
    Wang, Hao
    Wei, Ran
    Liu, Weiyan
    Chen, Yongqi
    Song, Bin
    BMC MEDICAL IMAGING, 2018, 18
  • [45] COMPARATIVE STUDY OF ACOUSTIC RADIATION FORCE IMPULSE IMAGING WITH REAL-TIME ELASTOGRAPHY IN DIFFERENTIAL DIAGNOSIS OF THYROID NODULES
    Zhan, Jia
    Diao, Xue-Hong
    Chai, Qi-Liang
    Chen, Yue
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12) : 2217 - 2225
  • [46] Preliminary study of ultrasonographic tissue quantification of the breast using the acoustic radiation force impulse (ARFI) technology
    Tozaki, Mitsuhiro
    Isobe, Sachiko
    Fukuma, Eisuke
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : E182 - E187
  • [47] McGill Thyroid Nodule Score in Differentiating Benign and Malignant Pediatric Thyroid Nodules: A Pilot Study
    Canfarotta, Michael
    Moote, Douglas
    Finck, Christine
    Riba-Wolman, Rebecca
    Thaker, Shefali
    Lerer, Trudy J.
    Payne, Richard J.
    Cote, Valerie
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2017, 157 (04) : 589 - 595
  • [48] The role of quantitative measurement by acoustic radiation force impulse imaging in differentiating benign renal lesions from malignant renal tumours
    Cemil Göya
    Mansur Daggulli
    Cihad Hamidi
    Alpaslan Yavuz
    Salih Hattapoglu
    Mehmet Guli Cetincakmak
    Memik Teke
    La radiologia medica, 2015, 120 : 296 - 303
  • [49] Acoustic radiation force impulse elastography in differentiating renal solid masses: a preliminary experience
    Guo, Le-Hang
    Liu, Bo-Ji
    Xu, Hui-Xiong
    Liu, Chang
    Sun, Li-Ping
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Wu, Jian
    Xu, Xiao-Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (11): : 7469 - 7476
  • [50] Diagnostic value of combined ultrasound contrast and elastography for differentiating benign and malignant thyroid nodules: a meta-analysis
    Liu, Funing
    Wang, Yihan
    Xiong, Yu
    Li, Xin
    Yao, Jun
    Ju, Hao
    Ren, Fu
    Zhang, Luwei
    Wang, Hongbo
    SCIENTIFIC REPORTS, 2024, 14 (01):