Preliminary Study on the Diagnostic Value of Acoustic Radiation Force Impulse Technology for Differentiating Between Benign and Malignant Thyroid Nodules

被引:0
|
作者
Gu, Jiying [1 ]
Du, Lianfang [1 ]
Bai, Min [1 ]
Chen, Huili [1 ]
Jia, Xiao [1 ]
Zhao, Jing [1 ]
Zhang, Xuemei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Ultrasound, Shanghai 200080, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Pathol, Shanghai 200080, Peoples R China
关键词
acoustic radiation force impulse; thyroid nodule; sonography; FINE-NEEDLE-ASPIRATION; IN-VIVO; ELASTOGRAPHY; ULTRASOUND; CANCER; US;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. Methods-Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging(VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the chi(2) test were used to compare the elastic parameters. Results-Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values +/- SD of 2.034 +/- 0.484, 1.835 +/- 0.364, 2.293 +/- 0.787, and 3.941 +/- 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). Conclusions-Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 50 条
  • [31] Diagnostic Value of Machine Learning-Based Quantitative Texture Analysis in Differentiating Benign and Malignant Thyroid Nodules
    Colakoglu, Bulent
    Alis, Deniz
    Yergin, Mert
    JOURNAL OF ONCOLOGY, 2019, 2019
  • [32] CLINICAL UTILITY OF QUALITATIVE ELASTOGRAPHY USING ACOUSTIC RADIATION FORCE IMPULSE FOR DIFFERENTIATING BENIGN FROM MALIGNANT SALIVARY GLAND TUMORS
    Matusda, Eriko
    Fukuhara, Takahiro
    Donishi, Ryohei
    Taira, Kenkichiro
    Koyama, Satoshi
    Morisaki, Tsuyoshi
    Fujiwara, Kazunori
    Takeuchitagedend, Hiromi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (02) : 279 - 287
  • [33] Comparative Efficacy of Ultrasonography and Acoustic Radiation Force Impulse (ARFI) Elastography in Prediction of Malignancy in Thyroid Nodules
    Goel, Sarika
    Malhotra, Ankur
    Agarwal, Arjit
    Chandak, Shruti
    Kumar, Ashutosh
    Khan, Adil
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2020, 36 (05) : 433 - 443
  • [34] Use of ultrasound elastography in differentiating benign from malignant thyroid nodules: a prospective study
    Awesh Shingare
    Aasim N. Maldar
    Phulrenu H. Chauhan
    Raju Wadhwani
    Journal of Diabetes & Metabolic Disorders, 2023, 22 : 1245 - 1253
  • [35] Diagnostic value of shear wave sonoelastography in differentiation of benign from malignant thyroid nodules
    Aghaghazvini, Leila
    Maheronnaghsh, Radin
    Soltani, Akbar
    Rouzrokh, Pouria
    Chavoshi, Mohammadreza
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [36] Clinical efficacy of novel elastography using acoustic radiation force impulse (ARFI) for diagnosis of malignant thyroid nodules
    Fukuhara, Takahiro
    Matsuda, Eriko
    Donishi, Ryohei
    Koyama, Satoshi
    Miyake, Naritomo
    Fujiwara, Kazunori
    Takeuchi, Hiromi
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2018, 3 (04): : 319 - 325
  • [37] An abdominal and thyroid status with Acoustic Radiation Force Impulse Elastometry - A feasibility study Acoustic Radiation Force Impulse Elastometry of human organs
    Goertz, R. S.
    Amann, K.
    Heide, R.
    Bernatik, T.
    Neurath, M. F.
    Strobel, D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E226 - E230
  • [38] Acoustic Radiation Force Impulse-Imaging for the evaluation of the thyroid gland: A limited patient feasibility study
    Friedrich-Rust, Mireen
    Romenski, Olga
    Meyer, Gesine
    Dauth, Nina
    Holzer, Katharina
    Gruenwald, Frank
    Kriener, Susanne
    Herrmann, Eva
    Zeuzem, Stefan
    Bojunga, Joerg
    ULTRASONICS, 2012, 52 (01) : 69 - 74
  • [39] Does Lesion Size Affect the Value of Shear Wave Elastography for Differentiating Between Benign and Malignant Thyroid Nodules?
    Wang, Fen
    Chang, Cai
    Chen, Min
    Gao, Yi
    Chen, Ya-Ling
    Zhou, Shi-Chong
    Li, Jia-Wei
    Zhi, Wen-Xiang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (03) : 601 - 609
  • [40] Prospective evaluation of acoustic radiation force impulse technology in the differentiation of thyroid nodules: Accuracy and interobserver variability assessment
    Grazhdani H.
    Cantisani V.
    Lodise P.
    Di Rocco G.
    Proietto M.C.
    Fioravanti E.
    Rubini A.
    Redler A.
    Journal of Ultrasound, 2014, 17 (1) : 13 - 20