Preliminary Study on the Diagnostic Value of Acoustic Radiation Force Impulse Technology for Differentiating Between Benign and Malignant Thyroid Nodules

被引:0
|
作者
Gu, Jiying [1 ]
Du, Lianfang [1 ]
Bai, Min [1 ]
Chen, Huili [1 ]
Jia, Xiao [1 ]
Zhao, Jing [1 ]
Zhang, Xuemei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Ultrasound, Shanghai 200080, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Pathol, Shanghai 200080, Peoples R China
关键词
acoustic radiation force impulse; thyroid nodule; sonography; FINE-NEEDLE-ASPIRATION; IN-VIVO; ELASTOGRAPHY; ULTRASOUND; CANCER; US;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. Methods-Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging(VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the chi(2) test were used to compare the elastic parameters. Results-Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values +/- SD of 2.034 +/- 0.484, 1.835 +/- 0.364, 2.293 +/- 0.787, and 3.941 +/- 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). Conclusions-Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 50 条
  • [21] Acoustic radiation force impulse elastography for differentiation of malignant and benign breast lesions: a meta-analysis
    Li, Dan-Dan
    Guo, Le-Hang
    Xu, Hui-Xiong
    Liu, Chang
    Xu, Jun-Mei
    Sun, Li-Ping
    Wu, Jian
    Liu, Bo-Ji
    Liu, Lin-Na
    Xu, Xiao-Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (04): : 4753 - 4761
  • [22] Malignancy risk assessment of category 4 nodules by applying acoustic radiation force impulse in thyroid imaging reporting and data system
    Chen, Qi
    Xing, Ping
    Liu, Qian-Qi
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (04): : 3473 - 3483
  • [23] Association between diagnostic efficacy of acoustic radiation force impulse for benign and malignant thyroid nodules and the presence or absence of non-papillary thyroid cancer: A meta-analysis
    Li, Jun
    Zhang, Yu-Rui
    Ren, Jia-Yu
    Li, Qiao-Li
    Zhu, Pei-Shan
    Du, Ting-Ting
    Ge, Xiao-Yan
    Chen, Ming
    Cui, Xin Wu
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [24] Diagnostic value of colour Doppler ultrasound in differentiating malignant and benign nodules in thyroiditis background
    Alamdaran, Seyed Ali
    Farshidianfar, Melika
    Masoumi, Alireza
    Rashed, Masoud Mahdavi
    Jaberi, Masoumeh
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2024, 71 (02) : 233 - 239
  • [25] Combination of conventional ultrasound and tissue quantification using acoustic radiation force impulse technology for differential diagnosis of small thyroid nodules
    Xing, Ping
    Chen, Qi
    Yang, Zhuo-Wen
    Liu, Chun-Bo
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (05): : 8288 - 8295
  • [26] Diagnostic value of ultrasonography and TI-201/Tc-99m dual scintigraphy in differentiating between benign and malignant thyroid nodules
    Watanabe, Ken
    Igarashi, Takao
    Ashida, Hirokazu
    Ogiwara, Sho
    Ohta, Tomoyuki
    Uchiyama, Mayuki
    Ojiri, Hiroya
    ENDOCRINE, 2019, 63 (02) : 301 - 309
  • [27] Acoustic radiation force impulse imaging (ARFI) for differentiation of benign and malignant thyroid nodules-A meta-analysis
    Zhan, Jia
    Jin, Jia-Mei
    Diao, Xue-Hong
    Chen, Yue
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2181 - 2186
  • [28] The diagnostic value of the different ARFI (acoustic radiation force impulse)-technique for solid thyroid nodules with different diameters: A case-control study
    Zhao, Na
    Chen, Jing
    Yao, Ming
    Han, Ruoling
    ASIAN JOURNAL OF SURGERY, 2022, 45 (11) : 2246 - 2252
  • [29] Differentiating Benign from Malignant Causes of Splenomegaly: Is Acoustic Radiation Force Impulse Elastography Helpful?
    Alhyari, Amjad
    Dob, Oussama
    Safai Zadeh, Ehsan
    Dietrich, Christoph Frank
    Trenker, Corrina
    Gress, Thomas M.
    Goerg, Christian
    DISEASES, 2024, 12 (12)
  • [30] Differentiating benign and malignant thyroid nodules: A cross-sectional study on the comparison of diagnostic value of ultrasound elastography and fine needle aspiration biopsy
    Rajabzadeh, Farnood
    Hassannejad, Ehsan
    Akhlaghipour, Iman
    Imen, Mohammad Javad
    Baghan, Atefeh Babazadeh
    Goshayeshi, Ladan
    Taghavi, Seyed Morteza
    Vojouhi, Shohreh
    Payandeh, Asma
    Ghalibaf, Amirali Moodi
    HEALTH SCIENCE REPORTS, 2023, 6 (10)