Use of fluoroscopy in clinical electrophysiology in Europe: results of the European Heart Rhythm Association Survey

被引:27
作者
Estner, Heidi L. [1 ]
Bongiorni, Maria Grazia [2 ]
Chen, Jian [3 ,4 ]
Dagres, Nikolaos [5 ]
Hernandez-Madrid, Antonio [6 ]
Blomstrom-Lundqvist, Carina [7 ]
机构
[1] Univ Munich, Dept Cardiol, Med Klin 1, D-81377 Munich, Germany
[2] Univ Hosp Pisa, Cardiol Dept 2, Pisa, Italy
[3] Haukeland Hosp, Dept Heart Dis, N-5021 Bergen, Norway
[4] Haukeland Hosp, Dept Clin Sci, N-5021 Bergen, Norway
[5] Univ Athens, Attikon Univ Hosp, Cardiol Dept 2, Athens, Greece
[6] Alcala Univ, Hosp Ramon y Cajal, Dept Cardiol, Madrid 28034, Spain
[7] Uppsala Univ, Inst Med Sci, Dept Cardiol, S-75185 Uppsala, Sweden
来源
EUROPACE | 2015年 / 17卷 / 07期
关键词
Radiation; Exposure; Fluoroscopy; X-ray; Electrophysiology; Ablation; Implantable cardioverter-defibrillator; 3D systems; EHRA survey; EP wire; ABLATION PROCEDURES;
D O I
10.1093/europace/euv223
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the advent of non-fluoroscopic technologies, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies to ablation interventions and device implantation. The purpose of the European Heart Rhythm Association survey was to provide an insight into regulatory policies and physicians' clinical practice when using fluoroscopy during ablation procedures and device implantation. The survey has shown that only 50% of the participating centres worked with low frame rates ( 3-6 frames per second) and that the left anterior oblique projection, with higher radiation exposure for the physician, is used for nearly every ablation target. Although three-dimensional imaging systems may reduce the radiation exposure, most centres never used these systems for standard ablation procedures and a trend is that non-fluoroscopy technologies are even less frequently used than in 2012, when the use of robotic systems was still rare. Even less costly equipment such as lead gloves, lead glass cabins, or radiation absorbing pads are still not routinely used.
引用
收藏
页码:1149 / 1152
页数:4
相关论文
共 4 条
[1]   Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures [J].
Heidbuchel, Hein ;
Wittkampf, Fred H. M. ;
Vano, Eliseo ;
Ernst, Sabine ;
Schilling, Richard ;
Picano, Eugenio ;
Mont, Lluis .
EUROPACE, 2014, 16 (07) :946-964
[2]   The use of imaging for electrophysiological and devices procedures: a report from the first European Heart Rhythm Association Policy Conference, jointly organized with the European Association of Cardiovascular Imaging (EACVI), the Council of Cardiovascular Imaging and the European Society of Cardiac Radiology [J].
Lundqvist, Carina Blomstrom ;
Auricchio, Angelo ;
Brugada, Josep ;
Boriani, Giuseppe ;
Bremerich, Jens ;
Angel Cabrera, Jose ;
Frank, Herbert ;
Gutberlet, Matthias ;
Heidbuchel, Hein ;
Kuck, Karl-Heinz ;
Lancellotti, Patrizio ;
Rademakers, Frank ;
Winkels, Gerard ;
Wolpert, Christian ;
Vardas, Panos E. .
EUROPACE, 2013, 15 (07) :927-936
[3]   X-ray exposure hazards for physicians performing ablation procedures and device implantation: results of the European Heart Rhythm Association survey [J].
Marinskis, Germanas ;
Bongiorni, Maria Grazia ;
Dagres, Nikolaos ;
Lewalter, Thorsten ;
Pison, Laurent ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2013, 15 (03) :444-446
[4]   Improving safety in the electrophysiology laboratory using a simple radiation dose reduction strategy: a study of 1007 radiofrequency ablation procedures [J].
Rogers, Dominic P. S. ;
England, Fiona ;
Lozhkin, Konstantin ;
Lowe, Martin D. ;
Lambiase, Pier D. ;
Chow, Anthony W. C. .
HEART, 2011, 97 (05) :366-370