Axial compressive behavior of new HFC-filled CTS composite walls sheathed with straw-fiber boards

被引:17
作者
Xu, Zhifeng [1 ,2 ,4 ]
Zhang, Jing [1 ,2 ]
Chen, Zhongfan [3 ,4 ]
Yang, Suhang [4 ,5 ]
Li, Jie [3 ,4 ]
机构
[1] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, Shandong Key Lab Civil Engn Disaster Prevent & Mi, Qingdao 266590, Peoples R China
[3] Southeast Univ, Sch Civil Engn, 02 Sipailou, Nanjing 210096, Peoples R China
[4] Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, 02 Sipailou, Nanjing 210096, Peoples R China
[5] Changzhou Inst Technol, Sch Civil Engn, Liaohelu 213032, Changzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
CTS composite wall; High-strength foamed concrete; Compression test; Failure mode; Axial compressive capacity; Calculation formula; SEISMIC PERFORMANCE; FOAMED CONCRETE; STEEL; PANELS; STUD;
D O I
10.1016/j.istruc.2020.10.065
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, an innovative high-strength foamed concrete (HFC)-filled cold-formed thin-walled steel (CTS) composite wall sheathed with straw-fiber boards (HFCS composite wall) was proposed. Six full-scale specimens of HFC-filled and unfilled CTS composite walls were tested under compression loading. The influence of HFC strength, stud cross-sectional area, wall thickness and sheathing as main parameters on axial compressive behavior of HFC-filled composite wall were analyzed. Test results indicated that using of HFC changed the failure mode of CTS frame from straw's shear failure to stud's local failure, and improved the wall's axial resistance capacity due to the restrictive effect of HFC on CTS-frame. Moreover, increasing HFC compressive strength further enhanced the bearing capacity of the HFCS composite wall, with little effect on its failure mode. Increasing CTS section area and wall thickness effectively avoided early the stud's local buckling, thereby improved the wall's compressive capacity. However, numerical analysis results showed that the most contribution of the wall components to axial compressive capacity of the HFCS composite wall is CTS studs (52.1%), followed by HFC (42.3%) and straw boards (5.6%), whereas straw board has no obvious effect. Finally, a practical formula for predicting the wall's axial resistance capacity was built by superposition method. The calculated results exhibited better agreement with test and numerical results.
引用
收藏
页码:2582 / 2595
页数:14
相关论文
共 34 条
[1]  
[Anonymous], 2012, DES STEEL STRUCT 1
[2]  
[Anonymous], 2011, 2662011 JGT MIN HOUS
[3]  
[Anonymous], 2016, 3832016 JGJ MIN HOUS
[4]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
[5]  
[Anonymous], 2013, 176572013 GBT MIN HO
[6]  
[Anonymous], 2014, 3412014 JGJT MIN HOU
[7]  
[Anonymous], 2002, 158562002 GBT MIN HO
[8]  
[Anonymous], 2015, AISIS400S416
[9]  
[Anonymous], 2010, 500102010 GB MIN HOU
[10]  
AS/NZS, 2018, AS/NZS4600:2018