关键词
frequency estimation; least mean squares methods; low-pass filters; power convertors; power distribution; power engineering computing; power grids; power harmonic filters; virtual instrumentation; unbalanced three-phase electrical distribution system frequency estimation; grid-connected power converters; complex least mean squares algorithm; CLMS algorithm; voltage amplitude unbalance; harmonic distortion levels; circular vector trajectory; two-phase i<plus; minus>i(2)-plane; constant delay block; signal frequency feedback loop; positive voltage phase-sequence vector; high signal harmonics; computer simulations; noise measurement; LabVIEW software environment; three-phase grid voltage; POWER QUALITY INSTRUMENTS; LOCKED LOOP; SYNCHRONIZATION; ALGORITHM;
D O I
10.1049/iet-smt.2012.0003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The subject of this study is a frequency estimation algorithm suitable for grid-connected power converters placed at a weak coupling point of a three-phase electrical distribution system. An upgraded version of the widely used complex least mean squares (CLMS) algorithm for frequency estimation is introduced to cope with different voltage amplitude unbalance and harmonic distortion levels, both frequently present in power system at distribution level. First, it is suggested that the CLMS algorithm uses only a positive phase-sequence component of voltage vector, the component that is inherently symmetrical and by cancelling the phase unbalance preserves the circular vector trajectory in a two-phase -plane. This study shows that it is even possible to use the positive voltage phase-sequence vector extracted using a constant delay block, thus avoiding potential instability issues in the case of signal frequency feedback loop. Second, possible high signal harmonics and signal measurement noise are both removed using low-pass filters prior to CLMS algorithm deployment. Computer simulations and experiments are performed under a variety of conditions to validate the effectiveness of the proposed technique. Experimental results are achieved using the dataset sampled from the actual three-phase grid voltage at distributed level and with data processing done in the LabVIEW software environment.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 50 条
  • [11] Bias-compensated normalised least mean square with variable step size algorithm for three-phase power system frequency estimation
    Ma, Wentao
    Qiu, Jinzhe
    Zhang, Zhiyu
    Zheng, Dongqiao
    Chen, Badong
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (07) : 1040 - 1047
  • [12] Three-Phase Unbalanced Voltage/VAR Optimization for Active Distribution Networks
    Zhao, Jinquan
    Liu, Xu
    Lin, Changnian
    Wei, Wenhui
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [13] Improved Frequency Estimation in Unbalanced Three-Phase Power System Using Coupled Orthogonal Constant Modulus Algorithm
    Zecevic, Zarko
    Krstajic, Bozo
    Popovic, Tomo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1809 - 1816
  • [14] JOINT FREQUENCY AND PHASOR ESTIMATION IN UNBALANCED THREE-PHASE POWER SYSTEMS
    Routtenberg, Tirza
    Tong, Lang
    2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [15] Optimal Restoration/Maintenance Switching Sequence of Unbalanced Three-Phase Distribution Systems
    Lopez, Juan Camilo
    Franco, John F.
    Rider, Marcos J.
    Romero, Ruben
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (06) : 6058 - 6068
  • [16] Enhanced Estimation of Frequency and Symmetrical Component Phasors of Three-Phase Voltage Signals
    Anirudh, C. V. S.
    Kumar, V. Seshadri Sravan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (03) : 1500 - 1511
  • [17] Widely Linear Modeling for Frequency Estimation in Unbalanced Three-Phase Power Systems
    Dini, Dahir H.
    Mandic, Danilo P.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (02) : 353 - 363
  • [18] A new accurate parameter estimation method for Unbalanced Three-Phase System based on correlation function
    Cherrak, Omar
    Omari, Mehdi
    Ghennioui, Hicham
    Lahbabi, M'hammed
    Abarkan, El Hossein
    2015 INTERNATIONAL CONFERENCE ON WIRELESS NETWORKS AND MOBILE COMMUNICATIONS (WINCOM), 2015, : 263 - 266
  • [19] Probabilistic method for the operation of three-phase unbalanced active distribution networks
    Mokryani, Geev
    Majumdar, Ankur
    Pal, Bikash C.
    IET RENEWABLE POWER GENERATION, 2016, 10 (07) : 944 - 954
  • [20] Estimation of Symmetrical Component Phasors and Frequency of Three-Phase Voltage Signals Using Transformations
    Anirudh, C. V. S.
    Kumar, V. Seshadri Sravan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (01) : 189 - 199