Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

被引:36
作者
Ketelsen, Dominik [1 ]
Luetkhoff, Marie H. [1 ]
Thomas, Christoph [1 ]
Werner, Matthias [1 ]
Buchgeister, Markus [2 ]
Tsiflikas, Ilias [1 ]
Reimann, Anja [1 ]
Burgstahler, Christof [3 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Univ Tubingen Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Radiotherapy & Radiooncol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
关键词
Dual-source computed tomography; Radiation exposure; Effective dose; Chest pain; ACUTE CORONARY SYNDROMES; TUBE-CURRENT MODULATION; MULTIDETECTOR ROW CT; EMERGENCY-ROOM; MULTISLICE CT; ANGIOGRAPHY; PATIENT; HISTORY; NOISE;
D O I
10.1007/s00330-008-1109-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [41] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Okayama, Satoshi
    Seno, Ayako
    Soeda, Tsunenari
    Takami, Yasuhiro
    Kawakami, Rika
    Somekawa, Satoshi
    Ishigami, Ken-ichi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Uemura, Shiro
    Saito, Yoshihiko
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 901 - 909
  • [42] Application value of preoperative dual-source computed tomography in assessing the rupture site of thoracic aortic dissection
    Huang, Fang
    Wu, Hong
    Lai, Qing-Quan
    Ke, Xiao-Ting
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2021, 16 (01)
  • [43] Dual-source computed tomography of the lung with spectral shaping and advanced iterative reconstruction: potential for maximum radiation dose reduction
    Matthias Wetzl
    Matthias S. May
    Daniel Weinmann
    Matthias Hammon
    Christoph Treutlein
    Martin Zeilinger
    Alexander Kiefer
    Regina Trollmann
    Joachim Woelfle
    Michael Uder
    Oliver Rompel
    [J]. Pediatric Radiology, 2020, 50 : 1240 - 1248
  • [44] Dual-source computed tomography of the lung with spectral shaping and advanced iterative reconstruction: potential for maximum radiation dose reduction
    Wetzl, Matthias
    May, Matthias S.
    Weinmann, Daniel
    Hammon, Matthias
    Treutlein, Christoph
    Zeilinger, Martin
    Kiefer, Alexander
    Trollmann, Regina
    Woelfle, Joachim
    Uder, Michael
    Rompel, Oliver
    [J]. PEDIATRIC RADIOLOGY, 2020, 50 (09) : 1240 - 1248
  • [45] Evaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography
    Rippel, K.
    Luitjens, J.
    Habeeballah, O.
    Scheurig-Muenkler, C.
    Bette, Stefanie
    Braun, Franziska
    Kroencke, T. J.
    Schwarz, F.
    Decker, J. A.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [46] Morphological and dynamic features of normal mitral valve evaluated by dual-source computed tomography
    Deng, Wen
    Yang, Zhi-gang
    Peng, Li-qing
    Dong, Zhi-hui
    Chu, Zhi-gang
    Wang, Qi-ling
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (03) : 633 - 636
  • [47] Predictors of aortic dilation in patients with coarctation of the aorta: evaluation with dual-source computed tomography
    Zhao, Qin
    Shi, Ke
    Yang, Zhi-gang
    Diao, Kai-yue
    Xu, Hua-yan
    Liu, Xi
    Guo, Ying-kun
    [J]. BMC CARDIOVASCULAR DISORDERS, 2018, 18
  • [48] Estimation and comparison of the radiation effective dose during coronary computed tomography angiography examinations on single-source 64-MDCT and dual-source 128-MDCT
    Khoramian, Daryoush
    Sistani, Soroush
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (04) : 826 - 836
  • [49] Usefulness of dual-source computed tomography for the evaluation of coronary arteries in heart transplant recipients
    Kepka, Cezary
    Sobieszczanska-Malek, Malgorzata
    Pregowski, Jerzy
    Kruk, Mariusz
    Bekta, Pawel
    Opolski, Maksymilian
    Komuda, Krzysztof
    Zielinski, Tomasz
    Witkowski, Adam
    Demkow, Marcin
    [J]. KARDIOLOGIA POLSKA, 2012, 70 (11) : 1111 - 1119
  • [50] Myocardial Ischemia Evaluation With Dual-source Computed Tomography: Comparison With Magnetic Resonance Imaging
    Delgado, Carlos
    Vazquez, Maria
    Oca, Roque
    Vilar, Manuel
    Trinidad, Carmen
    Sanmartin, Marcelo
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (11): : 864 - 870