Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

被引:36
作者
Ketelsen, Dominik [1 ]
Luetkhoff, Marie H. [1 ]
Thomas, Christoph [1 ]
Werner, Matthias [1 ]
Buchgeister, Markus [2 ]
Tsiflikas, Ilias [1 ]
Reimann, Anja [1 ]
Burgstahler, Christof [3 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Univ Tubingen Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Radiotherapy & Radiooncol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
关键词
Dual-source computed tomography; Radiation exposure; Effective dose; Chest pain; ACUTE CORONARY SYNDROMES; TUBE-CURRENT MODULATION; MULTIDETECTOR ROW CT; EMERGENCY-ROOM; MULTISLICE CT; ANGIOGRAPHY; PATIENT; HISTORY; NOISE;
D O I
10.1007/s00330-008-1109-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [31] Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography
    Karaarslan, Ercan
    Ulus, Sila
    Bavbek, Cengiz
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 407 - 414
  • [32] T and N Staging of Gastric Cancer Using Dual-Source Computed Tomography
    Xie, Zhao-Yong
    Chai, Rui-Mei
    Ding, Guo-Cheng
    Liu, Yi
    Ren, Ke
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [33] Dual-Source Computed Tomography Angiography in Aortic Stenosis: Comparison with Transthoracic Echocardiography
    Yaakup, Nur Adura
    Phuah, Hooi Fang
    Aziz, Yang Faridah Abdul
    Abidin, Imran Zainal
    Sun, Zhonghua
    Ng, Kwan Hoong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (05) : 749 - 755
  • [34] Preoperative evaluation of coronary artery fistula using dual-source computed tomography
    Jiang, Yaowen
    Liu, Peng
    Cao, Yu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 234 : 117 - 117
  • [35] Noninvasive Assessment of Coronary In-Stent Restenosis by Dual-Source Computed Tomography
    Pflederer, Tobias
    Marwan, Mohamed
    Renz, Alexandra
    Bachmann, Sven
    Ropers, Dieter
    Kuettner, Axel
    Anders, Katharina
    Bamberg, Fabian
    Daniel, Werner G.
    Achenbach, Stephan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (06) : 812 - 817
  • [36] Estimation of radiation exposure of different dose saving techniques in 128-slice computed tomography coronary angiography
    Ketelsen, Dominik
    Fenchel, Michael
    Buchgeister, Markus
    Thomas, Christoph
    Boehringer, Nadine
    Tsiflikas, Ilias
    Kaempf, Michael
    Syha, Roland
    Claussen, Claus D.
    Heuschmid, Martin
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : E153 - E157
  • [37] Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Busch, Stephanie
    Leber, Alexander W.
    Becker, Alexander
    Wintersperger, Bernd J.
    Rist, Carsten
    Knez, Andreas
    Reiser, Maximilian F.
    Becker, Christoph R.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (10) : 684 - 691
  • [38] Dual-Source Computed Tomography Evaluation of Children with Congenital Pulmonary Valve Stenosis
    Sun, Zhanguo
    Xu, Wenjian
    Huang, Shuran
    Chen, Yueqin
    Guo, Xiang
    Shi, Zhitao
    IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (02)
  • [39] Preoperative evaluation of coronary artery fistula using dual-source computed tomography
    Shi, Ke
    Gao, Hong-ling
    Yang, Zhi-gang
    Zhang, Qin
    Liu, Xi
    Guo, Ying-kun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 228 : 80 - 85
  • [40] Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography
    Satoshi Okayama
    Ayako Seno
    Tsunenari Soeda
    Yasuhiro Takami
    Rika Kawakami
    Satoshi Somekawa
    Ken-ichi Ishigami
    Yukiji Takeda
    Hiroyuki Kawata
    Manabu Horii
    Shiro Uemura
    Yoshihiko Saito
    The International Journal of Cardiovascular Imaging, 2012, 28 : 901 - 909