Potential of an air curtain system orientated to create non-uniform indoor thermal environment and save energy

被引:28
作者
Shen, Chong [1 ]
Shao, Xiaoliang [1 ,2 ]
Li, Xianting [1 ]
机构
[1] Tsinghua Univ, Beijing Key Lab Indoor Air Qual Evaluat & Control, Dept Bldg Sci, Beijing, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Mech Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Air curtain; Energy efficiency; Non-uniform environment; Indoor thermal environment; Ventilation; Cooling load; Coefficient of performance; DIFFERENT VENTILATION METHODS; COLD ROOM INFILTRATION; PERSONALIZED VENTILATION; PLANE JET; QUALITY; PERFORMANCES; PREDICTION; VELOCITY; ZONE;
D O I
10.1177/1420326X16659329
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Non-uniform indoor environment has shown its potential for building energy efficiency and improving indoor air quality compared with traditional uniform environment created by mixing ventilation. An air curtain was employed to create non-uniform thermal environment in this study. The performance of an optimal ventilation strategy between an air curtain and the background ventilation in a typical air-conditioned room was investigated numerically. The air curtain's effectiveness and coefficient of performance (COP) are proposed as evaluation indices for assessing the efficacy of air curtain for this usage. The numerical model was validated by experiments. The energy saving potential of an air curtain system for maintaining a thermal environment of a compartment was studied under different internal heat-source characteristics. The discharge velocity of the air curtain was optimized. The results show that the efficacy of an air curtain system to create a non-uniform thermal environment is high, where the maximum temperature difference between two sides of an air curtain could be as high as 7.4?. Both the flow rate of the air curtain and background ventilation can be reduced to save energy. An air curtain is more efficient when the heat is concentrated mainly in the unoccupied room partition and the unoccupied zone contains external walls.
引用
收藏
页码:152 / 165
页数:14
相关论文
共 32 条
[1]  
Adams P.J., 1985, ASHRAE T, V91, P423
[2]   Modelling and experimental study of performance of the protected occupied zone ventilation [J].
Cao, Guangyu ;
Siren, Kai ;
Kilpelainen, Simo .
ENERGY AND BUILDINGS, 2014, 68 :515-531
[3]   Experimental study of the effect of turbulence intensities on the maximum velocity decay of an attached plane jet [J].
Cao, Guangyu ;
Kandzia, Claudia ;
Mueller, Dirk ;
Heikkinen, Jorma ;
Kosonen, Risto ;
Ruponen, Mika .
ENERGY AND BUILDINGS, 2013, 65 :127-136
[4]  
Carlson DA, 2006, J ECON ENTOMOL, V99, P182, DOI 10.1603/0022-0493(2006)099[0182:POMDCA]2.0.CO
[5]  
2
[6]   Modular ventilation with twin air curtains for reducing dispersed pollution [J].
Ciocanea, Adrian ;
Dragomirescu, Andrei .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2013, 37 :180-198
[7]  
Department of housing and urban-rural development of Zhejiang Province, 2021, DES STAND EN EFF PUB
[8]   Heat confinement in tunnels between two double-stream twin-jet air curtains [J].
Elicer-Cortes, J. C. ;
Demarco, R. ;
Valencia, A. ;
Pavageau, M. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (05) :438-444
[9]   Three-dimensional effects of an air curtain used to restrict cold room infiltration [J].
Foster, A. M. ;
Swain, M. J. ;
Barrett, R. ;
D'Agaro, P. ;
Ketteringham, L. P. ;
James, S. J. .
APPLIED MATHEMATICAL MODELLING, 2007, 31 (06) :1109-1123
[10]   Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration [J].
Foster, A. M. ;
Swain, M. J. ;
Barrett, R. ;
D'Agaro, P. ;
James, S. J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (05) :692-699