SARS-CoV-2 RNA contamination on surfaces of a COVID-19 ward in a hospital of Northern Italy: what risk of transmission?

被引:19
作者
D'accolti, M. [1 ,2 ]
Soffritti, I [1 ,2 ]
Passaro, A. [3 ,4 ]
Zuliani, G. [3 ,4 ]
Antonioli, P. [5 ]
Mazzacane, S. [2 ]
Manfredini, R. [3 ,6 ]
Caselli, E. [1 ,2 ]
机构
[1] Univ Ferrara, Dept Chem & Pharmaceut Sci, Sect Microbiol, Ferrara, Italy
[2] Univ Ferrara, CIAS Res Ctr, Ferrara, Italy
[3] S Anna Univ Hosp, COVID 19 Internal Med Units, Ferrara, Italy
[4] Univ Ferrara, Dept Morphol Surg & Expt Med, Ferrara, Italy
[5] S Anna Univ Hosp, Dept Infect Prevent Control & Risk Management, Ferrara, Italy
[6] Univ Ferrara, Dept Med Sci, Ferrara, Italy
关键词
SARS-CoV-2; COVID-19; Hospital environmental contamination; VIRUSES;
D O I
10.26355/eurrev_202009_22872
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: SARS-CoV-2 can reportedly exist on inanimate surfaces for a long duration, but there is limited data available from Italian COVID-19 hospital wards, especially for non-intensive care units hosting patients that do not require mechanical ventilation. Identification of the extent of environmental contamination can help in understanding possible virus transmission routes, limit hospital infections and protect healthcare workers. Thus, we investigated virus contamination on surfaces of the acute COVID-19 ward of an Italian hospital. MATERIALS AND METHODS: Ward surfaces, including four points inside and six points outside the patients' rooms were sampled by swabs, seven hours after routine sanitation. To minimize the risk of underestimation of virus detection, tw/odifferent sensitive molecular methods were used comparatively, and specific internal controls were added to enhance the efficiency of all the analysis steps. RESULTS: SARS-CoV-2 contamination was detected in only three out of all the collected samples, i.e., on two floors and one-bathroom sink, likely reflecting aerosol and saliva contamination, respectively. The overall level of contamination was low, and the floors exhibited a very low level of SARS-CoV-2 presence, evidenced by only one of the two methods used. CONCLUSIONS: The existence of SARS-CoV-2 on hospital surfaces may be limited, although it was reported to persist fora longer duration on surfaces under controlled laboratory conditions. Thus, effective transmission of SARS-CoV-2 by surfaces/fomites within the hospital ward may be a rare event. However, the results highlight the importance of assessing method sensitivity and including controls when investigating low-level virus contamination so as to avoid the risk of underestimation of virus presence.
引用
收藏
页码:9202 / 9207
页数:6
相关论文
共 18 条
[1]   SURVIVAL OF INFLUENZA-VIRUSES ON ENVIRONMENTAL SURFACES [J].
BEAN, B ;
MOORE, BM ;
STERNER, B ;
PETERSON, LR ;
GERDING, DN ;
BALFOUR, HH .
JOURNAL OF INFECTIOUS DISEASES, 1982, 146 (01) :47-51
[2]   Reducing healthcare-associated infections incidence by a probiotic-based sanitation system: A multicentre, prospective, intervention study [J].
Caselli, Elisabetta ;
Brusaferro, Silvio ;
Coccagna, Maddalena ;
Arnoldo, Luca ;
Berloco, Filippo ;
Antonioli, Paola ;
Tarricone, Rosanna ;
Pelissero, Gabriele ;
Nola, Silvano ;
La Fauci, Vincenza ;
Conte, Alessandro ;
Tognon, Lorenzo ;
Villone, Giovanni ;
Trua, Nelso ;
Mazzacane, Sante .
PLOS ONE, 2018, 13 (07)
[3]   Impact of a Probiotic-Based Cleaning Intervention on the Microbiota Ecosystem of the Hospital Surfaces: Focus on the Resistome Remodulation [J].
Caselli, Elisabetta ;
D'Accolti, Maria ;
Vandini, Alberta ;
Lanzoni, Luca ;
Camerada, Maria Teresa ;
Coccagna, Maddalena ;
Branchini, Alessio ;
Antonioli, Paola ;
Balboni, Pier Giorgio ;
Di Luca, Dario ;
Mazzacane, Sante .
PLOS ONE, 2016, 11 (02)
[4]  
Cerbara L, 2020, EUR REV MED PHARMACO, V24, P7155, DOI 10.26355/eurrev_202006_21711
[5]  
Chakraborty C, 2020, EUR REV MED PHARMACO, V24, P4016, DOI 10.26355/eurrev_202004_20871
[6]   Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients [J].
Chia, Po Ying ;
Coleman, Kristen Kelli ;
Tan, Yian Kim ;
Ong, Sean Wei Xiang ;
Gum, Marcus ;
Lau, Sok Kiang ;
Lim, Xiao Fang ;
Lim, Ai Sim ;
Sutjipto, Stephanie ;
Lee, Pei Hua ;
Son, Than The ;
Young, Barnaby Edward ;
Milton, Donald K. ;
Gray, Gregory C. ;
Schuster, Stephan ;
Barkharn, Timothy ;
De, Partha Pratim ;
Vasoo, Shawn ;
Chan, Monica ;
Ang, Brenda Sze Peng ;
Tan, Boon Huan ;
Leo, Yee-Sin ;
Ng, Oon-Tek ;
Wong, Michelle Su Yen ;
Marimuthu, Kalisvar .
NATURE COMMUNICATIONS, 2020, 11 (01)
[7]   Transmission characteristics of MERS and SARS in the healthcare setting: a comparative study [J].
Chowell, Gerardo ;
Abdirizak, Fatima ;
Lee, Sunmi ;
Lee, Jonggul ;
Jung, Eunok ;
Nishiura, Hiroshi ;
Viboud, Cecile .
BMC MEDICINE, 2015, 13
[8]   Lack of SARS-CoV-2 RNA environmental contamination in a tertiary referral hospital for infectious diseases in Northern Italy [J].
Colaneri, M. ;
Seminari, E. ;
Piralla, A. ;
Zuccaro, V. ;
Filippo, A. Di ;
Baldanti, F. ;
Bruno, R. ;
Mondelli, M. U. .
JOURNAL OF HOSPITAL INFECTION, 2020, 105 (03) :474-476
[9]   Introduction of NGS in Environmental Surveillance for Healthcare-Associated Infection Control [J].
Comar, Manola ;
D'Accolti, Maria ;
Cason, Carolina ;
Soffritti, Irene ;
Campisciano, Giuseppina ;
Lanzoni, Luca ;
Bisi, Matteo ;
Volta, Antonella ;
Mazzacane, Sante ;
Caselli, Elisabetta .
MICROORGANISMS, 2019, 7 (12)
[10]   Fighting AMR in the Healthcare Environment: Microbiome-Based Sanitation Approaches and Monitoring Tools [J].
D'Accolti, Maria ;
Soffritti, Irene ;
Mazzacane, Sante ;
Caselli, Elisabetta .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (07)