Effects of substrate preparation on TiO2 morphology and topography during anodization of biomedical Ti6Al4V

被引:13
作者
Cheung, Keng Ho [1 ]
Pabbruwe, Moreica Beatrice [2 ]
Chen, Wen-Fan [1 ,3 ]
Koshy, Pramod [1 ]
Sorrell, Charles Christopher [1 ]
机构
[1] UNSW Sydney, Sch Mat Sci & Engn, Sydney, NSW 2052, Australia
[2] Royal Perth Hosp, Dept Med Engn & Phys, Perth, WA 6847, Australia
[3] Natl Sun Yat Sen Univ, Inst Med Sci & Technol, Kaohsiung 80424, Taiwan
基金
澳大利亚研究理事会;
关键词
Ti6Al4V; Anodization; Roughness; Morphology; Topography; ANODIC-OXIDATION PARAMETERS; SCREW-SHAPED IMPLANTS; OSTEOBLAST-LIKE CELLS; DIELECTRIC-BREAKDOWN; SURFACE MODIFICATION; TITANIUM-ALLOYS; OXIDE-FILMS; ROUGHNESS; EXPANSION; COATINGS;
D O I
10.1016/j.matchemphys.2020.123224
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
TiO2 coatings were fabricated by anodizing unpolished and polished Ti6Al4V substrates in 1-3 M H2SO4 for 10 and 20 min at 120 V. Anatase was the principal polymorph and oxygen dissolution in the Ti6Al4V substrates caused alpha Ti lattice contraction. Dielectric breakdown and associated heating of the insulating TiO2 promoted trace rutile formation. The surface preparation of the Ti6Al4V substrates was the principal factor that determined not only the grain and pore sizes but also the morphology and topography of the coating. Consequently, the presence of the amorphous TiO2 passivating layer (unpolished) resulted in thicker and more irregular coatings than when anodization was done on the bare metal surface (polished). Large-scale delamination steps were observed for the coatings on the unpolished substrates while localized delaminations occurred for the coatings on polished substrates; the amounts of both increased with increasing anodization time. 3D laser scanning confocal microscopy allowed distinction between the fine-scale morphology and the coarse-scale topography. These data showed that increasing time and acid concentration resulted in similar trends of increasing roughness (morphology) and unevenness (topography). The present work focusses on the effect of initial substrate surface characteristics and its modification to improve the quality of the coatings formed by anodization of titanium biomedical implants.
引用
收藏
页数:13
相关论文
共 70 条
  • [1] DIELECTRIC-BREAKDOWN PROCESSES IN ANODIC TA2O5 AND RELATED OXIDES - A REVIEW
    ALBELLA, JM
    MONTERO, I
    MARTINEZDUART, JM
    PARKHUTIK, V
    [J]. JOURNAL OF MATERIALS SCIENCE, 1991, 26 (13) : 3422 - 3432
  • [2] Osteoblast adhesion on biomaterials
    Anselme, K
    [J]. BIOMATERIALS, 2000, 21 (07) : 667 - 681
  • [3] Anselme K., 2005, BIOMATER, V25, P4731
  • [4] The effect of annealing temperatures on surface properties, hydroxyapatite growth and cell behaviors of TiO2 nanotubes
    Bai, Yu
    Park, Song
    Park, Hyeoung Ho
    Lee, Min Ho
    Bae, Tae Sung
    Duncan, Warwick
    Swain, Andmichael
    [J]. SURFACE AND INTERFACE ANALYSIS, 2011, 43 (06) : 998 - 1005
  • [5] FORMATION OF POROUS FILMS ON TITANIUM-ALLOYS BY ANODIZATION
    BAUN, WL
    [J]. SURFACE TECHNOLOGY, 1980, 11 (06): : 421 - 430
  • [6] Bowers K T, 1992, Int J Oral Maxillofac Implants, V7, P302
  • [7] DIELECTRIC BREAKDOWN IN ELECTROLYTIC CAPACITORS
    BURGER, FJ
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1971, 118 (12) : 2039 - &
  • [8] Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
  • [9] Cytotoxicity Evaluation of Anatase and Rutile TiO2 Thin Films on CHO-K1 Cells in Vitro
    Cervantes, Blanca
    Lopez-Huerta, Francisco
    Vega, Rosario
    Hernandez-Torres, Julian
    Garcia-Gonzalez, Leandro
    Salceda, Emilio
    Herrera-May, Agustin L.
    Soto, Enrique
    [J]. MATERIALS, 2016, 9 (08)
  • [10] Additively manufactured 3D porous Ti-6Al-4V constructs mimic trabecular bone structure and regulate osteoblast proliferation, differentiation and local factor production in a porosity and surface roughness dependent manner
    Cheng, Alice
    Humayun, Aiza
    Cohen, David J.
    Boyan, Barbara D.
    Schwartz, Zvi
    [J]. BIOFABRICATION, 2014, 6 (04)