Impact of Commissural Misalignment on Hydrodynamic Function Following Valve-in-Valve Intervention With the ACURATE neo

被引:6
作者
Meier, David [1 ,2 ,3 ,4 ]
Akodad, Mariama [1 ,2 ,3 ,4 ]
Chatfield, Andrew G. [1 ,2 ,3 ,4 ]
Lutter, Georg [5 ,6 ]
Puehler, Thomas [5 ,6 ]
Sondergaard, Lars [7 ]
Wood, David A. [1 ,4 ]
Webb, John G. [1 ,4 ]
Sellers, Stephanie L. [1 ,2 ,3 ,4 ,8 ]
Sathananthan, Janarthanan [1 ,2 ,3 ,4 ,8 ]
机构
[1] St Pauls & Vancouver Gen Hosp, Ctr Cardiovasc Innovat, Vancouver, BC, Canada
[2] St Pauls Hosp, Cardiovasc Translat Lab, Vancouver, BC, Canada
[3] Ctr Heart Lung Innovat, Vancouver, BC, Canada
[4] Univ British Columbia, St Pauls Hosp, Ctr Heart Valve Innovat, Vancouver, BC, Canada
[5] German Ctr Cardiovasc Res, Partner Site Kiel Hamburg Lubeck, Kiel, Germany
[6] Univ Med Ctr Schleswig Holsten, Dept Cardiac & Vasc Surg, Campus Kiel, Kiel, Germany
[7] Copenhagen Univ Hosp, Rigshosp, Copenhagen, Denmark
[8] Ctr Heart Lung Innovat & Providence Res, Vancouver, BC, Canada
关键词
ACURATE neo; commissural alignment; transcatheter heart valve; valve-in-valve; AORTIC-VALVE; IMPLANTATION; BIOPROSTHESES; REPLACEMENT; ALIGNMENT;
D O I
10.1016/j.jcin.2022.05.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Limited evidence is available regarding valve-in-valve (VIV) intervention with the ACURATE neo transcatheter heart valve (THV). Low implantation has demonstrated leaflet interaction between the surgical bioprosthesis and the THV, leading to impaired hydrodynamic performance. It is unknown if commissural alignment (CA) can affect this phenomenon. Novel techniques have now been developed to achieve CA with the ACURATE neo THV. OBJECTIVES The aim of this study was to assess the impact of commissural misalignment (CMA) on hydrodynamic function following VIV intervention with the ACURATE neo THV using a bench model. METHODS VIV intervention was performed with the ACURATE neo (a self-expanding THV with supra-annular leaflet position) implanted deep in the surgical bioprosthetic aortic valve (Mitroflow). Hydrodynamic function at CA (0 degrees) and 3 different degrees of CMA (30 degrees, 60 degrees, and 90 degrees) was tested. As per the International Organization for Standardization, a regurgitant fraction <20% is considered optimal. RESULTS Following VIV, the central THV regurgitant fraction at 0 degrees, 30 degrees, 60 degrees, and 90 degrees of CMA was 8.6% +/- 2.0%, 30.3% +/- 12.0%, 42.6% +/- 11.9%, and 66.7% +/- 25.4% (P < 0.0001), respectively. On high-speed video there was no evidence of leaflet interaction at CA, whereas at 30 degrees, 60 degrees, and 90 degrees of CMA there was clear evidence of THV leaflet interaction with those of the surgical valve, leading to impaired leaflet closure and to severe central THV regurgitation. CONCLUSIONS In VIV using the ACURATE neo THV at deep implantation, increasing degree of CMA was associated with THV leaflet interaction with those of the surgical valve and worsening regurgitant fraction. THV leaflet interaction was prevented when there was CA. (C) 2022 by the American College of Cardiology Foundation.
引用
收藏
页码:1532 / 1539
页数:8
相关论文
共 18 条
[1]   The impact of imperfect frame deployment and rotational orientation on stress within the prosthetic leaflets during transcatheter aortic valve implantation [J].
Bailey, Jonathon ;
Curzen, Nick ;
Bressloff, Neil W. .
JOURNAL OF BIOMECHANICS, 2017, 53 :22-28
[2]   The Mitroflow aortic valve: A past, present, and future illuminated [J].
Balsam, Leora B. ;
DeAnda, Abe, Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01) :40-42
[3]   Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves [J].
Bieliauskas, Gintautas ;
Wong, Ivan ;
Bajoras, Vilhelmas ;
Wang, Xi ;
Kofoed, Klaus Fuglsang ;
De Backer, Ole ;
Sondergaard, Lars .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (19) :2097-2108
[4]   Direct TAVI using a balloon-expandable system: a novel technique to eliminate pre-deployment balloon aortic valvuloplasty [J].
Davies, William R. ;
Bapat, Vinayak N. ;
Hancock, Jane E. ;
Young, Christopher P. ;
Redwood, Simon R. ;
Thomas, Martyn R. .
EUROINTERVENTION, 2014, 10 (02) :248-252
[5]   Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves Results From the Global Valve-in-Valve Registry [J].
Dvir, Danny ;
Webb, John ;
Brecker, Stephen ;
Bleiziffer, Sabine ;
Hildick-Smith, David ;
Colombo, Antonio ;
Descoutures, Fleur ;
Hengstenberg, Christian ;
Moat, Neil E. ;
Bekeredjian, Raffi ;
Napodano, Massimo ;
Testa, Luca ;
Lefevre, Thierry ;
Guetta, Victor ;
Nissen, Henrik ;
Hernandez, Jose-Maria ;
Roy, David ;
Teles, Rui C. ;
Segev, Amit ;
Dumonteil, Nicolas ;
Fiorina, Claudia ;
Gotzmann, Michael ;
Tchetche, Didier ;
Abdel-Wahab, Mohamed ;
De Marco, Federico ;
Baumbach, Andreas ;
Laborde, Jean-Claude ;
Kornowski, Ran .
CIRCULATION, 2012, 126 (19) :2335-+
[6]   Commissural Alignment of Bioprosthetic Aortic Valve and Native Aortic Valve Following Surgical and Transcatheter Aortic Valve Replacement and its Impact on Valvular Function and Coronary Filling [J].
Fuchs, Andreas ;
Kofoed, Klaus F. ;
Yoon, Sung-Han ;
Schaffner, Yannick ;
Bieliauskas, Gintautas ;
Thyregod, Hans Gustav ;
Makkar, Raj ;
Sondergaard, Lars ;
De Backer, Ole ;
Bapat, Vinayak .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (17) :1733-1743
[7]   Dynamic analysis of the aortic valve using a finite element model [J].
Gnyaneshwar, R ;
Kumar, RK ;
Balakrishnan, KR .
ANNALS OF THORACIC SURGERY, 2002, 73 (04) :1122-1129
[8]   An in vitro evaluation of turbulence after transcatheter aortic valve implantation [J].
Hatoum, Hoda ;
Yousefi, Atieh ;
Lilly, Scott ;
Maureira, Pablo ;
Crestanello, Juan ;
Dasi, Lakshmi P. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (05) :1837-1848
[9]   Implantation Depth and Rotational Orientation Effect on Valve-in-Valve Hemodynamics and Sinus Flow [J].
Hatoum, Hoda ;
Dollery, Jennifer ;
Lilly, Scott M. ;
Crestanello, Juan A. ;
Dasi, Lakshmi Prasad .
ANNALS OF THORACIC SURGERY, 2018, 106 (01) :70-78
[10]   Valve-in-Valve Implantation Using the ACURATE Neo in Degenerated Aortic Bioprostheses An International Multicenter Analysis [J].
Holzamer, Andreas ;
Kim, Won-Keun ;
Ruck, Andreas ;
Sathananthan, Janarthanan ;
Keller, Lukas ;
Cosma, Joseph ;
Bauer, Timm ;
Nef, Holger ;
Amat-Santos, Ignacio J. ;
Brinkert, Miriam ;
Husser, Oliver ;
Pellegrini, Costanza ;
Schofer, Joachim ;
Nerla, Roberto ;
Montorfano, Matteo ;
Giannini, Francesco ;
Stella, Pieter ;
Kuwata, Shingo ;
Hilker, Michael ;
Castriota, Fausto ;
Ussia, Gian Paolo ;
Webb, John G. ;
Nietlispach, Fabian ;
Toggweiler, Stefan .