Simultaneous determination of inorganic anions and cations by supercritical fluid chromatography using evaporative light scattering detection

被引:17
|
作者
Foulon, Catherine [1 ]
Di Giulio, Pauline [1 ]
Lecoeur, Marie [1 ]
机构
[1] Univ Lille, EA 7365, Grp Rech Formes Injectables & Technol Asssociees, GRITA, F-59000 Lille, France
关键词
Evaporative light scattering detector (ELSD); Inorganic anion and cation; 2-Ethylpyridine stationary phase (2-EP); Supercritical fluid chromatography (SFC); INTERACTION LIQUID-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; STATIONARY-PHASE; ION CHROMATOGRAPHY; ADDITIVES; SILICA; SEPARATION; COLUMN; PHARMACEUTICALS; METOPROLOL;
D O I
10.1016/j.chroma.2017.12.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Supercritical fluid chromatography (SFC) is commonly used for the analysis of non-polar compounds, but remains poorly explored for the separation of polar and ionized molecules. In this paper, SFC has-been investigated for the separation of 14 inorganic ions sampled in aqueous solutions. Four polar stationary phases were first screened using CO2-methanol-based mobile phases containing water or different acidic or basic additives, in order to select the most efficient conditions for the simultaneous retention of inorganic cations and anions and to favor their detection using evaporative light scattering detector (ELSD). Orthogonal selectivity was obtained depending on the stationary phase used: whereas anions are less retained on HILIC stationary phase, 2-ethylpyridine (2-EP) stationary phase exhibits strong interaction for anions. Best results were obtained under gradient elution mode using a 2-EP stationary phase and by adding 0.2% triethylamine in the CO2-methanol-based mobile phase. The composition of the injection solvent was also investigated. The results showed that a methanolic sample containing a percentage of water not exceeding 20% does not affect the analytical performances obtained on 2-EP. Moreover, the presence of triethylamine in the injection solvent contributes to eliminate peaks shoulders. Among the 14 inorganic ions tested, three cations (Li+, Ca2+ and Mg2+) and five anions (Cl-, Br-, NO3-, I-, SCN-) were totally resolved in 15 min. NO3- and NO2- still coeluted in the final optimized conditions. The other investigated ions were either strongly retained on the stationary phase or not detected by the ELSD. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 50 条
  • [1] Determination of inorganic cations and anions by ion-exchange chromatography with evaporative light-scattering detection
    Mouchère, F
    El Haddad, M
    Elfakir, C
    Dreux, M
    JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) : 167 - 173
  • [2] Simultaneous determination of inorganic anions and methyl and ethylphosphonic acids by anion exchange chromatography using evaporative light scattering detection
    Mercier, JP
    Elfakir, C
    Dreux, M
    Lazar, S
    El Haddad, M
    Akssira, M
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (15) : 2345 - 2359
  • [3] Evaporative light scattering detection for supercritical fluid chromatography
    Strode, JTB
    Taylor, LT
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (06) : 261 - 271
  • [4] SIMULTANEOUS DETERMINATION OF INORGANIC ANIONS AND CATIONS BY ION CHROMATOGRAPHY WITH INDIRECT PHOTOMETRIC DETECTION
    GAO, JZ
    BIAN, HJ
    HOU, JG
    KANG, JW
    JOURNAL OF CHROMATOGRAPHY A, 1993, 657 (01) : 95 - 101
  • [5] Fast determination of substitution patterns of methylated cyclodextrins by supercritical fluid chromatography using evaporative light scattering detection.
    Salvador, A
    Herbreteau, B
    Lafosse, M
    Dreux, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 31 - ANYL
  • [6] Conditions for rapid determination of inorganic cations in water by ion-exchange chromatography and evaporative light scattering detection
    El Haddad, Mohammadine
    Mouchère, Fabrice
    Elfakir, Claire
    Dreux, Michel
    2001, Wiley-VCH Verlag (24)
  • [7] Conditions for rapid determination of inorganic cations in water by ion-exchange chromatography and evaporative light scattering detection
    El Haddad, M
    Mouchère, F
    Elfakir, C
    Dreux, M
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (08) : 669 - 673
  • [8] A NEW APPROACH FOR THE SIMULTANEOUS DETERMINATION OF INORGANIC CATIONS AND ANIONS USING ION CHROMATOGRAPHY
    HU, WZ
    TAO, H
    TOMINAGA, M
    MIYAZAKI, A
    HARAGUCHI, H
    ANALYTICA CHIMICA ACTA, 1994, 299 (02) : 249 - 256
  • [9] Isocratic conditions for analysis of inorganic anions by ion exchange chromatography with evaporative light scattering detection
    El Haddad, M
    Lazar, S
    Akssira, M
    Dreux, M
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (1-2) : 23 - 28
  • [10] Free bile acid analysis by supercritical fluid chromatography and evaporative light scattering detection
    Villette, V
    Herbreteau, B
    Lafosse, M
    Dreux, M
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (11) : 1805 - 1818