Poor reproducibility of classification of proximal humeral fractures - Additional CT of minor value

被引:91
作者
Sjoden, GOJ [1 ]
Movin, T [1 ]
Guntner, P [1 ]
Aspelin, P [1 ]
Ahrengart, L [1 ]
Ersmark, H [1 ]
Sperber, A [1 ]
机构
[1] HUDDINGE UNIV HOSP,KAROLINSKA INST,DEPT RADIOL,S-14186 HUDDINGE,SWEDEN
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1997年 / 68卷 / 03期
关键词
COMPUTED-TOMOGRAPHY; OBSERVER VARIATION; 4-PART FRACTURES; RELIABILITY; KAPPA; NECK;
D O I
10.3109/17453679708996692
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fractures of the proximal humerus can be described using the Neer and AO fracture classifications. To assess the reproducibility and reliability of these classifications, we investigated 26 proximal humeral fractures with both plain radiographs and CT. 5 specialists in orthopedic surgery and 5 specialists in radiology independently classified all radiographs on 2 occasions. There was a moderate agreement between the observers when using the Neer classification, but only a fair agreement with the AO classification. The Neer system had a kappa value of 0.42 and the AO had a value of 0.31 in the first assessment. In the second assessment the kappa Values were 0.45 and 0.30, respectively. Intraobserver reproducibility was slight to almost perfect agreement with Neer (kappa range 0.20-0.85) and slight to moderate agreement with AO (kappa range 0.16-0.60). The observers most familiar with shoulder fracture radiographs and shoulder fracture treatment were more consistent in their classifications. We conclude that even with GT,the fracture classifications of Neer and AO have a low consistency. Neither classification system is reproducible enough to allow comparisons of different studies.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 33 条
[1]   EVANS CLASSIFICATION OF TROCHANTERIC FRACTURES - AN ASSESSMENT OF THE INTEROBSERVER AND INTRAOBSERVER RELIABILITY [J].
ANDERSEN, E ;
JORGENSEN, LG ;
HEDEDAM, LT .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (06) :377-378
[2]  
Barloon T.J., 1990, INVEST RADIOL, V25, P133
[3]  
BASS JC, 1990, INVEST RADIOL, V9, P994
[4]   Evaluation of the Neer system of classification of proximal humeral fractures with computerized tomographic scans and plain radiographs [J].
Bernstein, J ;
Adler, LM ;
Blank, JE ;
Dalsey, RM ;
Williams, GR ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1371-1375
[5]   COMPUTED-TOMOGRAPHY IN TRAUMATOLOGY WITH SPECIAL REGARD TO THE ADVANCES OF 3-DIMENSIONAL DISPLAY [J].
BILLET, FPJ ;
SCHMITT, WGH ;
GAY, B .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 111 (03) :131-137
[6]   NEERS CLASSIFICATION-SYSTEM - A CRITICAL-APPRAISAL [J].
BRIEN, H ;
NOFTALL, F ;
MACMASTER, S ;
CUMMINGS, T ;
LANDELLS, C ;
ROCKWOOD, P .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (02) :257-260
[8]   PATIENT-CARE AND SCIENTIFIC FREEDOM [J].
COWELL, HR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (05) :640-641
[9]   GARDEN CLASSIFICATION OF FEMORAL-NECK FRACTURES - AN ASSESSMENT OF INTER-OBSERVER VARIATION [J].
FRANDSEN, PA ;
ANDERSEN, E ;
MADSEN, F ;
SKJODT, T .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :588-590
[10]   NATURE OF EFFECT OF SET ON PERCEPTION [J].