Multilayer 10B-RPC neutron imaging detector

被引:7
作者
Margato, L. M. S. [1 ]
Morozov, A. [1 ]
Blanco, A. A. [1 ]
Fonte, P. [1 ,2 ]
Lopes, L. [1 ]
Zeitelhack, K. [3 ]
Hall-Wilton, R. [4 ,5 ,6 ]
Hoeglund, C. [4 ,7 ]
Robinson, L. [4 ]
Schmidt, S. [4 ,8 ]
Svensson, P. [4 ]
机构
[1] Univ Coimbra, Dept Fis, LIP Coimbra, Rua Largo, P-3004516 Coimbra, Portugal
[2] Coimbra Polytech, ISEC, Coimbra, Portugal
[3] Tech Univ Munich, FRM II, Heinz Maier Leibnitz Zentrum MLZ, D-85748 Garching, Germany
[4] European Spallat Source ERIC ESS, POB 176, SE-22100 Lund, Sweden
[5] Univ Milano Bicocca, ESS, Piazza Sci 3, I-20126 Milan, Italy
[6] Univ Milano Bicocca, Dipartimento Fis G Occhialini, Piazza Sci 3, I-20126 Milan, Italy
[7] Impact Coatings AB, Westmansgatan 29G, SE-58216 Linkoping, Sweden
[8] IHI Ionbond AG, Ind Str 211, CH-4600 Olten, Switzerland
基金
欧盟地平线“2020”;
关键词
Neutron detectors (cold; thermal; fast neutrons); Gaseous detectors; Resistive-plate chambers; COUNTER;
D O I
10.1088/1748-0221/15/06/P06007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Resistive plate chambers (RPC) lined with (B4C)-B-10 neutron converters is a promising cost-effective technology for position-sensitive thermal neutron detection capable to outperform He-3-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of (B4C)-B-10 at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap B-10-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer B-10-RPCs detector with a stack of ten double-gap hybrid RPCs. A description of the detector design and the results of its characterization performed at the TREFF neutron beamline at the FRM II neutron facility are presented. The results demonstrate that the detection efficiency exceeds 60% for neutrons with a wavelength of 4.7 angstrom and the spatial resolution (FWHM) is about 0.25 mm and 0.35 mm in the X and Y direction, respectively.
引用
收藏
页数:12
相关论文
共 21 条
[1]   10B multi-grid proportional gas counters for large area thermal neutron detectors [J].
Andersen, K. ;
Bigault, T. ;
Birch, J. ;
Buffet, J. C. ;
Correa, J. ;
Hall-Wilton, R. ;
Hultman, L. ;
Hoglund, C. ;
Guerard, B. ;
Jensen, J. ;
Khaplanov, A. ;
Kirstein, O. ;
Piscitelli, F. ;
Van Esch, P. ;
Vettier, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 720 :116-121
[2]   TOFtracker: gaseous detector with bidimensional tracking and time-of-flight capabilities [J].
Blanco, A. ;
Fonte, P. ;
Lopes, L. ;
Martins, P. ;
Michel, J. ;
Palka, M. ;
Kajetanowicz, M. ;
Korcyl, G. ;
Traxler, M. ;
Marques, R. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[3]   In-beam measurements of the HADES-TOF RPC wall [J].
Blanco, A. ;
Cabanelas, P. ;
Belver, D. ;
Castro, E. ;
Diaz, J. ;
Fonte, P. ;
Gil, A. ;
Garzon, J. A. ;
Gonzalez-Diaz, D. ;
Heinz, T. ;
Koenig, W. ;
Lopes, L. ;
Muentz, C. ;
Palka, M. ;
Pietraszko, J. ;
Rustamov, A. ;
Schwab, E. ;
Sobolev, Y. ;
Tarantola, A. ;
Teilab, K. ;
Traxler, M. ;
Trebacz, R. ;
Wuestenfeld, J. ;
Yurevich, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (03) :691-695
[4]   THE RESISTIVE PLATE COUNTER AS A NEUTRON DETECTOR [J].
CALLIGARICH, E ;
CARDARELLI, R ;
CESANA, A ;
COLANGELO, S ;
RASELLI, GL ;
SANDRELLI, G ;
TERRANI, M ;
TESTI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (01) :142-144
[5]   The trigger system of a large area RPC TOF-tracker muon telescope [J].
Clemencio, F. ;
Blanco, A. ;
Carolino, N. ;
Loureiro, C. .
JOURNAL OF INSTRUMENTATION, 2018, 13
[6]   The 10B based Jalousie neutron detector - An alternative for 3He filled position sensitive counter tubes [J].
Henske, M. ;
Klein, M. ;
Koehli, M. ;
Lennert, P. ;
Modzel, G. ;
Schmidt, C. J. ;
Schmidt, U. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 686 :151-155
[7]   Stability of 10B4C thin films under neutron radiation [J].
Hoglund, Carina ;
Zeitelhack, Karl ;
Kudejova, Petra ;
Jensen, Jens ;
Greczynski, Grzegorz ;
Lu, Jun ;
Hultman, Lars ;
Birch, Jens ;
Hall-Wilton, Richard .
RADIATION PHYSICS AND CHEMISTRY, 2015, 113 :14-19
[8]   B4C thin films for neutron detection [J].
Hoglund, Carina ;
Birch, Jens ;
Andersen, Ken ;
Bigault, Thierry ;
Buffet, Jean-Claude ;
Correa, Jonathan ;
van Esch, Patrick ;
Guerard, Bruno ;
Hall-Wilton, Richard ;
Jensen, Jens ;
Khaplanov, Anton ;
Piscitelli, Francesco ;
Vettier, Christian ;
Vollenberg, Wilhelmus ;
Hultman, Lars .
JOURNAL OF APPLIED PHYSICS, 2012, 111 (10)
[9]  
Kirstein O., 2014, PoS Vertex2014, P029, DOI DOI 10.22323/1.227.0029
[10]   Boron Coated Straw Detectors as a Replacement for 3He [J].
Lacy, Jeffrey L. ;
Athanasiades, Athanasios ;
Sun, Liang ;
Martin, Christopher S. ;
Vazquez-Flores, Gerson J. .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :119-125