Diagnostic value of cone-beam CT in histologically confirmed otosclerosis

被引:27
作者
Liktor, Balazs [1 ,2 ]
Revesz, Peter [3 ]
Csomor, Peter [4 ]
Gerlinger, Imre [3 ]
Sziklai, Istvan [5 ]
Karosi, Tamas [1 ,2 ]
机构
[1] BAZ Cty Hosp, Dept Otolaryngol & Head & Neck Surg, H-3526 Miskolc, Hungary
[2] Univ Hosp, H-3526 Miskolc, Hungary
[3] Univ Pecs, Sch Med, Dept Otolaryngol & Head & Neck Surg, Pecs, Hungary
[4] Univ Debrecen, Dept Rheumatol, Med & Hlth Sci Ctr, H-4012 Debrecen, Hungary
[5] Univ Debrecen, Dept Otolaryngol & Head & Neck Surg, Med & Hlth Sci Ctr, H-4012 Debrecen, Hungary
基金
匈牙利科学研究基金会;
关键词
Cone-beam computed tomography; Hearing loss; Histopathology; Otosclerosis; RESOLUTION COMPUTED-TOMOGRAPHY; TEMPORAL BONE; HEARING-LOSS; COCHLEAR IMPLANTATION; STAPES FIXATIONS; HISTOPATHOLOGY;
D O I
10.1007/s00405-013-2702-y
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
This retrospective case review was performed with the aim to asses the value of cone-beam computed tomography (CBCT) in the preoperative diagnosis of otosclerosis. A total of 32 patients with histologically confirmed stapedial otosclerosis, who underwent unilateral stapedectomies were analyzed. Preoperative temporal bone CBCT scans were performed in all cases. CBCT imaging was characterized by a slice thickness of 0.3 mm and multiplanar image reconstruction. Histopathologic examination of the removed stapes footplates was performed in all cases. Findings of CBCT were categorized according to Marshall's grading system (from grade 0 to grade 3). Histopathologic results were correlated to multiplanar reconstructed CBCT scans, respectively. Histologically active foci of otosclerosis (n = 21) were identified by CBCT in all cases with a sensitivity of 100 %. However, CBCT was unable to detect histologically inactive otosclerosis (n = 11, sensitivity = 0 %). According to CBCT scans, no retrofenestral lesions were found and all positive cases were recruited into the grade 1 group indicating solely fenestral lesions at the anterior pole of stapes footplates. In conclusion, CBCT is a reliable imaging method with considerably lower radiation dose than high-resolution CT (HRCT) in the preoperative diagnosis of otosclerosis. These results indicate that CBCT has high sensitivity and specificity in the detection of hypodense lesions due to histologically active otosclerosis.
引用
收藏
页码:2131 / 2138
页数:8
相关论文
共 25 条
[1]   Pathophysiology of otosclerosis [J].
Chole, RA ;
McKenna, M .
OTOLOGY & NEUROTOLOGY, 2001, 22 (02) :249-257
[2]   Prevalence of histologic otosclerosis: An unbiased temporal bone study in Caucasians [J].
Declau, F. ;
van Spaendonck, M. ;
Timmermans, J. P. ;
Michaels, L. ;
Liang, J. ;
Qiu, J. P. ;
van de Heyning, P. .
Otosclerosis and Stapes Surgery, 2007, 65 :6-16
[3]   Temporal bone density measurements using CT in otosclerosis [J].
Grayeli, AB ;
Saint Yrieix, C ;
Imauchi, Y ;
Cyna-Gorse, F ;
Ferrary, E ;
Sterkers, O .
ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) :1136-1140
[4]   HISTOPATHOLOGY OF THE STAPES IN OTOSCLEROSIS [J].
IYER, PV ;
GRISTWOOD, RE .
PATHOLOGY, 1984, 16 (01) :30-38
[5]   The Value of HRCT in Stapes Fixations Corresponding to Hearing Thresholds and Histologic Findings [J].
Karosi, Tamas ;
Csomor, Peter ;
Sziklai, Istvan .
OTOLOGY & NEUROTOLOGY, 2012, 33 (08) :1300-1307
[6]   Histopathology of Nonotosclerotic Stapes Fixations [J].
Karosi, Tamas ;
Csomor, Peter ;
Petko, Mihaly ;
Liktor, Balint ;
Szabo, Laszlo Z. ;
Pytel, Jozsef ;
Jori, Jozsef ;
Sziklai, Istvan .
OTOLOGY & NEUROTOLOGY, 2009, 30 (08) :1058-1066
[7]   Correlation of CT analysis and audiometry in Japanese otosclerosis [J].
Kiyomizu, K ;
Tono, T ;
Yang, DW ;
Haruta, A ;
Kodama, T ;
Komune, S .
AURIS NASUS LARYNX, 2004, 31 (02) :125-129
[8]   Reliability of High-Resolution CT Scan in Diagnosis of Otosclerosis [J].
Lagleyre, Sebastien ;
Sorrentino, Tommaso ;
Calmels, Marie-Noelle ;
Shin, Young-Je ;
Escude, Bernard ;
Deguine, Olivier ;
Fraysse, Bernard .
OTOLOGY & NEUROTOLOGY, 2009, 30 (08) :1152-1159
[9]   CT Grading of Otosclerosis [J].
Lee, T. C. ;
Aviv, R. I. ;
Chen, J. M. ;
Nedzelski, J. M. ;
Fox, A. J. ;
Symons, S. P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (07) :1435-1439
[10]   USE OF CT IN STAPEDIAL OTOSCLEROSIS [J].
MAFEE, MF ;
HENRIKSON, GC ;
DEITCH, RL ;
NOROUZI, P ;
KUMAR, A ;
KRIZ, R ;
VALVASSORI, GE .
RADIOLOGY, 1985, 156 (03) :709-714