Proximal Isovelocity Surface Area by Single-Beat Three-Dimensional Color Doppler Echocardiography Applied for Tricuspid Regurgitation Quantification

被引:61
作者
Alberto de Agustin, Jose [1 ]
Viliani, Dafne [1 ]
Vieira, Catarina [1 ]
Islas, Fabian [1 ]
Marcos-Alberca, Pedro [1 ]
Juan Gomez de Diego, Jose [1 ]
Javier Nunez-Gil, Ivan [1 ]
Almeria, Carlos [1 ]
Luis Rodrigo, Jose [1 ]
Luaces, Maria [1 ]
Angel Garcia-Fernandez, Miguel [1 ]
Macaya, Carlos [1 ]
Perez de Isla, Leopoldo [1 ]
机构
[1] Hosp Univ San Carlos, Unidad Imagen Cardiaca, Inst Cardiovasc, Madrid 28040, Spain
关键词
Proximal isovelocity surface area; Three-dimensional echocardiography; Tricuspid regurgitation; TWO-DIMENSIONAL ECHOCARDIOGRAPHY; FLOW CONVERGENCE REGION; IN-VITRO; VALVULAR REGURGITATION; VALVE DISEASE; QUANTITATIVE ASSESSMENT; VOLUME FLOW; BLOOD-FLOW; REAL-TIME; ORIFICE;
D O I
10.1016/j.echo.2013.06.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The two-dimensional (2D) proximal isovelocity surface area (PISA) method has known technical limitations, mainly the geometric assumptions of PISA shape required to calculate effective regurgitant orifice area (EROA). Recently developed single-beat real-time three-dimensional (3D) color Doppler imaging allows the direct measurement of PISA without geometric assumptions and has already been validated for mitral regurgitation assessment. The aim of this study was to apply this novel method in patients with chronic tricuspid regurgitation (TR). Methods: Ninety patients with chronic TR were enrolled. EROA and regurgitant volume (Rvol) were assessed using transthoracic 2D and 3D PISA methods. Quantitative Doppler and 3D transthoracic planimetry of EROA were used as reference methods. Results: Both EROA and Rvol assessed using the 3D PISA method had better correlations with the reference methods than using conventional 2D PISA, particularly in the assessment of eccentric jets. On the basis of 3D planimetry-derived EROA, 35 patients had severe TR (EROA $ 0.4 cm 2). Among these 35 patients, 25.7% (n = 9) were underestimated as having nonsevere TR (EROA# 0.4 cm 2) using the 2D PISA method. In contrast, the 3D PISA method had 94.3% agreement (33 of 35) with 3D planimetry in classifying severe TR. Good intraobserver and interobserver agreement for 3D PISA measurements was observed, with intraclass correlation coefficients of 0.92 and 0.88 respectively. Conclusions: TR quantification using PISA by single-beat real-time 3D color Doppler echocardiography is feasible in the clinical setting and more accurate than the conventional 2D PISA method.
引用
收藏
页码:1063 / 1072
页数:10
相关论文
共 38 条
[1]   Direct Measurement of Proximal Isovelocity Surface Area by Single-Beat Three-Dimensional Color Doppler Echocardiography in Mitral Regurgitation: A Validation Study [J].
Alberto de Agustin, Jose ;
Marcos-Alberca, Pedro ;
Fernandez-Golfin, Covadonga ;
Goncalves, Alexandra ;
Feltes, Gisela ;
Javier Nunez-Gil, Ivan ;
Almeria, Carlos ;
Luis Rodrigo, Jose ;
Perez de Isla, Leopoldo ;
Macaya, Carlos ;
Zamorano, Jose .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (08) :815-823
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   COMPUTER-ANALYSIS OF DOPPLER COLOR FLOW MAPPING IMAGES FOR QUANTITATIVE ASSESSMENT OF INVITRO FLUID JETS [J].
BOLGER, AF ;
EIGLER, NL ;
PFAFF, JM ;
RESSER, KJ ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :450-457
[4]   Right-Sided Valve Disease Deserves a Little More RESPECT [J].
Bruce, Charles J. ;
Connolly, Heidi M. .
CIRCULATION, 2009, 119 (20) :2726-2734
[5]   ADJACENT SOLID BOUNDARIES ALTER THE SIZE OF REGURGITANT JETS ON DOPPLER COLOR FLOW MAPS [J].
CAPE, EG ;
YOGANATHAN, AP ;
WEYMAN, AE ;
LEVINE, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) :1094-1102
[6]  
CARPENTIER A, 1974, J THORAC CARDIOV SUR, V67, P53
[7]   CAN TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND DOPPLER COLOR FLOW MAPPING IDENTIFY THE NEED FOR TRICUSPID-VALVE REPAIR [J].
CHOPRA, HK ;
NANDA, NC ;
FAN, P ;
KAPUR, KK ;
GOYAL, R ;
DARUWALLA, D ;
PACIFICO, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1266-1274
[8]   Quantitative assessment of regurgitant flow with total digital three-dimensional reconstruction of color Doppler flow in the convergent region: In vitro validation [J].
Coisne, D ;
Erwan, D ;
Christiaens, L ;
Blouin, P ;
Allal, J ;
Barraine, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (03) :233-240
[9]   Influence of the orifice inlet angle on the velocity profile across a flow convergence region by color Doppler in vitro [J].
Giesler, M ;
Stein, M ;
Grossmann, G ;
Hombach, V .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (05) :419-428
[10]   Random walks for image segmentation [J].
Grady, Leo .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2006, 28 (11) :1768-1783