Comparison [3H]-flumazenil binding parameters in rat cortical membrane using different separation methods, filtration and centrifugation

被引:11
作者
Ahmadi, Fatemeh [1 ]
Faizi, Mehrdad [2 ]
Tabatabai, Sayyed Abbas [3 ]
Beiki, Davood [4 ]
Shahhosseini, Soraya [3 ]
机构
[1] Univ Tehran Med Sci, Sch Pharm, Dept Radiopharm, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmacol & Toxicol, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut Chem, Tehran, Iran
[4] Univ Tehran Med Sci, Res Ctr Nucl Med, Tehran, Iran
基金
美国国家科学基金会;
关键词
Radioligand receptor binding assay; H-3]-flumazenil; Liquid scintillation; Filtration; Centrifugation; BENZODIAZEPINE SITE; PHARMACOPHORE MODEL; LIGANDS; DERIVATIVES; DESIGN; IDENTIFICATION; AFFINITY;
D O I
10.1016/j.nucmedbio.2013.06.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radioligand receptor binding assays are a common method to evaluate the affinity of newly synthesized benzodiazepine ligands for the receptor. [H-3]-flumazenil is an antagonist of benzodiazepine receptors and is generally used as a radioligand. In this study, the binding parameters of [H-3]-flumazenil to rat cortical membranes were evaluated using two separation methods: filtration with GF/C filters and centrifugation. Additionally, the effects of vacuum pressure, exposure time to the cocktail, and geometry on the filtration method were studied. The binding parameters of [H-3]-flumazenil (K-d and B-max) were determined through saturation studies using two methods. The results from this study showed that the filtration method is time consuming and requires more steps to be completed. Because filtration causes partial elution of bound [H-3]flumazenil into the liquid scintillation cocktail, the results are not reproducible, which result in inaccurate estimation of the binding parameters. The centrifugation method in contrast to filtration is straightforward and produces reproducible as well as reliable results, all of the steps are performed in a single polypropylene tube, which eliminates the loss of tissue and avoids other systematic errors associated with transfer and handling. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:896 / 900
页数:5
相关论文
共 27 条
[1]   Design and synthesis of 4H-3-(2-phenoxy)phenyl-1,2,4-triazole derivatives as benzodiazepine receptor agonists [J].
Akbarzadeh, T ;
Tabatabai, SA ;
Khoshnoud, MJ ;
Shafaghi, B ;
Shafiee, A .
BIOORGANIC & MEDICINAL CHEMISTRY, 2003, 11 (05) :769-773
[2]   COMPARISON OF THE FILTRATION AND CENTRIFUGATION METHODS FOR ASSAYING [3H](D-ALA2,D-LEU5)ENKEPHALIN BINDING TO MOUSE-BRAIN MEMBRANES [J].
BARRETT, RW ;
VAUGHT, JL .
NEUROCHEMICAL RESEARCH, 1983, 8 (12) :1547-1556
[3]  
BENNETT J-P., 1978, NEUROTRANSMITTER REC, P57
[4]  
Bigott-Hennkens HM, 2008, Q J NUCL MED MOL IM, V52, P245
[5]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[6]  
Burns DA, COUNTING SOLUTIONS L
[7]   3-phenyl-6-(2-pyridyl)methyloxy-1,2,4-triazolo[3,4-α]phthalazines and analogues:: High-affinity γ-aminobutyric acid-A benzodiazepine receptor ligands with α2, α3, and α5-subtype binding selectivity over α1 [J].
Carling, RW ;
Moore, KW ;
Street, LJ ;
Wild, D ;
Isted, C ;
Leeson, PD ;
Thomas, S ;
O'Connor, D ;
McKernan, RM ;
Quirk, K ;
Cook, SM ;
Atack, JR ;
Wafford, KA ;
Thompson, SA ;
Dawson, GR ;
Ferris, P ;
Castro, JL .
JOURNAL OF MEDICINAL CHEMISTRY, 2004, 47 (07) :1807-1822
[8]  
CONCAS A, 1993, J PHARMACOL EXP THER, V267, P844
[9]  
Davenport A.P., 1996, Current directions in radiopharmaceutical research and development, P169
[10]  
Faizi M, 2012, IRAN J PHARM RES, V11, P83