Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties

被引:132
作者
Ambrosio, Renato, Jr. [1 ,2 ]
Ramos, Isaac [1 ,2 ]
Luz, Allan [2 ]
Faria, Fernando Correa [1 ,2 ]
Steinmueller, Andreas [3 ]
Krug, Matthias [3 ]
Belin, Michael W. [4 ]
Roberts, Cynthia Jane [5 ]
机构
[1] Inst Olhos Renato Ambrosio, Rio De Janeiro, RJ, Brazil
[2] Rio de Janeiro Corneal Tomog & Biomech Study Grp, Rio De Janeiro, RJ, Brazil
[3] Oculus GmbH, Wetzlar, Germany
[4] Univ Arizona, Tucson, AZ USA
[5] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
关键词
Biomechanics; Cornea/physiology; Corneal topography/methods; Tonometry; ocular/methods; KERATOCONUS;
D O I
10.1590/S0034-72802013000200005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To describe a novel technique for clinical characterization of corneal biomechanics using non-invasive dynamic imaging. Methods: Corneal deformation response during non contact tonometry (NCT) is monitored by ultra-high-speed (UHS) photography. The Oculus Corvis ST (Scheimpflug Technology; Wetzlar, Germany) has a UHS Scheimpflug camera, taking over 4,300 frames per second and of a single 8mm horizontal slit, for monitoring corneal deformation response to NCT. The metered collimated air pulse or puff has a symmetrical configuration and fixed maximal internal pump pressure of 25 kPa. The bidirectional movement of the cornea in response to the air puff is monitored. Results: Measurement time is 30ms, with 140 frames acquired. Advanced algorithms for edge detection of the front and back corneal contours are applied for every frame. IOP is calculated based on the first applanation moment. Deformation amplitude (DA) is determined as the highest displacement of the apex in the highest concavity (HC) moment. Applanation length (AL) and corneal velocity (CVel) are recorded during ingoing and outgoing phases. Conclusion: Corneal deformation can be monitored during non contact tonometry. The parameters generated provide clinical in vivo characterization of corneal biomechanical properties in two dimensions, which is relevant for different applications in Ophthalmology.
引用
收藏
页码:99 / 102
页数:4
相关论文
共 20 条
[1]  
Ambrosio Jr R, 2012, OFTALMOLOGIA FOCO, V138, P31
[2]  
Ambrosio Renato Jr, 2011, Int Ophthalmol Clin, V51, P11, DOI 10.1097/IIO.0b013e31820f1d2d
[3]   BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[4]   Proposal for a new approach to corneal biomechanics: dynamic corneal topography [J].
Bonatti, Jose Americo ;
Bechara, Samir Jacob ;
Carricondo, Pedro Carlos ;
Kara-Jose, Newton .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (02) :264-267
[5]   Corneal structure and biomechanics: impact on the diagnosis and management of glaucoma [J].
Brown, Kimberly E. ;
Congdon, Nathan G. .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (04) :338-343
[6]   Age-Related Differences in the Elasticity of the Human Cornea [J].
Cartwright, Nathaniel E. Knox ;
Tyrer, John R. ;
Marshall, John .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) :4324-4329
[7]   Keratoconus prediction using a finite element model of the cornea with local biomechanical properties [J].
Carvalho, Luis Alberto ;
Prado, Marcelo ;
Cunha, Rodivaldo H. ;
Costa Neto, Alvaro ;
Paranhos, Augusto, Jr. ;
Schor, Paulo ;
Chamon, Wallace .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (02) :139-145
[8]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[9]   Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneas [J].
Dorronsoro, Carlos ;
Pascual, Daniel ;
Perez-Merino, Pablo ;
Kling, Sabine ;
Marcos, Susana .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (03) :473-487
[10]   Biomechanics and wound healing in the cornea [J].
Dupps, William J., Jr. ;
Wilson, Steven E. .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (04) :709-720