Free-Breathing Variable Flip Angle Balanced SSFP Cardiac Cine Imaging with Reduced SAR at 3T

被引:3
作者
Srinivasan, Subashini [1 ,2 ]
Kroeker, Randall M. [3 ]
Gabriel, Simon [1 ]
Plotnik, Adam [1 ]
Godinez, Sergio R. [1 ]
Hu, Peng [1 ,4 ]
Halnon, Nancy [5 ]
Finn, J. Paul [1 ,4 ]
Ennis, Daniel B. [1 ,2 ,4 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA USA
[3] Siemens Canada Ltd, Winnipeg, MB, Canada
[4] Univ Calif Los Angeles, Biomed Phys Interdept Program, Los Angeles, CA USA
[5] Univ Calif Los Angeles, Dept Pediat, Los Angeles, CA 90024 USA
关键词
free-breathing cardiac cine imaging; variable flip angle; bSSFP; STATE FREE PRECESSION; RETROSPECTIVE RECONSTRUCTION; MAGNETIC-RESONANCE; MOTION CORRECTION; MR; ACQUISITIONS; IMAGES;
D O I
10.1002/mrm.26011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a free-breathing variable flip angle (VFA) balanced steady-state free precession (bSSFP) cardiac cine imaging technique with reduced specific absorption rate (SAR) at 3 Tesla. Methods: Free-breathing VFA (FB-VFA) images in the short-axis and four-chamber views were acquired using an optimal VFA scheme, then compared with conventional breath-hold constant flip angle (BH-CFA) acquisitions. Two cardiac MRI experts used a 5-point scale to score images from healthy subjects (N = 10). The left ventricular ejection fraction, end diastolic volume (LVEDV), end systolic volume, stroke volume (LVSV), and end diastolic myocardial mass (LVEDM) were determined by manual contour analysis for BH-CFA and FB-VFA. A pilot evaluation of FB-VFA was performed in one patient with Duchenne muscular dystrophy. Results: FB-VFA SAR was 25% lower than BH-CFA with similar blood-myocardium contrast. The qualitative FB-VFA score was lower than the BH-CFA for the short-axis (3.1 +/- 0.5 versus 4.3 +/- 0.8; P < 0.05) and the four-chamber view (3.4 +/- 0.4 versus 4.6 +/- 0.6; P < 0.05). The LVEDV and the LVSV were 5% and 12% larger (P < 0.05) for FB-VFA compared with BH-CFA. There was no difference in LVEDM. Conclusion: FB-VFA bSSFP cardiac cine imaging decreased the SAR at 3T with image quality sufficient to perform cardiac functional analysis. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1210 / 1216
页数:7
相关论文
共 18 条
  • [1] Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency
    Deshpande, VS
    Shea, SM
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) : 803 - 809
  • [2] Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    Dietrich, Olaf
    Raya, Jose G.
    Reeder, Scott B.
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) : 375 - 385
  • [3] MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES
    EHMAN, RL
    MCNAMARA, MT
    PALLACK, M
    HRICAK, H
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1175 - 1182
  • [4] Cardiomyopathy in Duchenne muscular dystrophy: pathogenesis and therapeutics
    Fayssoil, Abdallah
    Nardi, Olivier
    Orlikowski, David
    Annane, Djillali
    [J]. HEART FAILURE REVIEWS, 2010, 15 (01) : 103 - 107
  • [5] Cardiac MR imaging: State of the technology
    Finn, J. Paul
    Nael, Kambiz
    Deshpande, Vibhas
    Ratib, Osman
    Laub, Gerhard
    [J]. RADIOLOGY, 2006, 241 (02) : 338 - 354
  • [6] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [7] Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction
    Hansen, Michael S.
    Sorensen, Thomas S.
    Arai, Andrew E.
    Kellman, Peter
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 741 - 750
  • [8] High Spatial and Temporal Resolution Cardiac Cine MRI from Retrospective Reconstruction of Data Acquired in Real Time Using Motion Correction and Resorting
    Kellman, Peter
    Chefd'hotel, Christophe
    Lorenz, Christine H.
    Mancini, Christine
    Arai, Andrew E.
    McVeigh, Elliot R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) : 1557 - 1564
  • [9] On flow effects in balanced steady-state free precession imaging: Pictorial description, parameter dependence, and clinical implications
    Markl, M
    Pelc, NJ
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) : 697 - 705
  • [10] Flow effects in balanced steady state free precession imaging
    Markl, M
    Alley, MT
    Elkins, CJ
    Pelc, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 892 - 903