Programmable mechanical stimulation influences tendon homeostasis in a bioreactor system

被引:112
作者
Wang, Tao [1 ]
Lin, Zhen [1 ,2 ]
Day, Robert E. [3 ]
Gardiner, Bruce [4 ]
Landao-Bassonga, Euphemie [1 ]
Rubenson, Jonas [5 ]
Kirk, Thomas B. [6 ]
Smith, David W. [4 ]
Lloyd, David G. [7 ]
Hardisty, Gerard [8 ]
Wang, Allan [9 ]
Zheng, Qiujian [2 ]
Zheng, Ming H. [1 ]
机构
[1] Univ Western Australia, Sch Surg, Ctr Orthopaed Translat Res, Med Ctr QE2, Crawley, WA 6009, Australia
[2] Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Surg, Div Orthopaed Surg, Guangzhou, Guangdong, Peoples R China
[3] Royal Perth Hosp, Dept Med Engn & Phys, Perth, WA, Australia
[4] Univ Western Australia M002, Sch Comp Sci & Software Engn, Crawley, WA, Australia
[5] Univ Western Australia M408, Sch Sport Sci Exercise & Hlth Musculoskeletal Tis, Crawley, WA, Australia
[6] Curtin Univ Technol, Chancellory, WA, Australia
[7] Griffith Univ, Griffith Hlth Inst, Ctr Musculoskeletal Res, Gold Coast Campus, Qld, Australia
[8] St John God Med Clin, Subiaco, WA, Australia
[9] Sir Charles Gairdner Hosp, Nedlands, WA 6009, Australia
关键词
bioreactor; programmable mechanical stimulation; tendon; collagen; AUTOLOGOUS TENOCYTE THERAPY; COLLAGEN SPONGE CONSTRUCTS; MESSENGER-RNA EXPRESSION; ACHILLES TENDINOPATHY; ECCENTRIC EXERCISE; MMP-1; EXPRESSION; GENE-EXPRESSION; STRAIN; CELLS; INCREASES;
D O I
10.1002/bit.24809
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Identification of functional programmable mechanical stimulation (PMS) on tendon not only provides the insight of the tendon homeostasis under physical/pathological condition, but also guides a better engineering strategy for tendon regeneration. The aims of the study are to design a bioreactor system with PMS to mimic the in vivo loading conditions, and to define the impact of different cyclic tensile strain on tendon. Rabbit Achilles tendons were loaded in the bioreactor with/without cyclic tensile loading (0.25Hz for 8h/day, 09% for 6 days). Tendons without loading lost its structure integrity as evidenced by disorientated collagen fiber, increased type III collagen expression, and increased cell apoptosis. Tendons with 3% of cyclic tensile loading had moderate matrix deterioration and elevated expression levels of MMP-1, 3, and 12, whilst exceeded loading regime of 9% caused massive rupture of collagen bundle. However, 6% of cyclic tensile strain was able to maintain the structural integrity and cellular function. Our data indicated that an optimal PMS is required to maintain the tendon homeostasis and there is only a narrow range of tensile strain that can induce the anabolic action. The clinical impact of this study is that optimized eccentric training program is needed to achieve maximum beneficial effects on chronic tendinopathy management. Biotechnol. Bioeng. 2013; 110: 14951507. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1495 / 1507
页数:13
相关论文
共 59 条
  • [1] Tendon Tissue Engineering Using Cell-Seeded Umbilical Veins Cultured in a Mechanical Stimulator
    Abousleiman, Rita I.
    Reyes, Yuliana
    McFetridge, Peter
    Sikavitsas, Vassilios
    [J]. TISSUE ENGINEERING PART A, 2009, 15 (04) : 787 - 795
  • [2] Heavy-load eccentric calf muscle training for the treatment of chronic Achilles tendinosis
    Alfredson, H
    Pietila, T
    Jonsson, P
    Lorentzon, P
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) : 360 - 366
  • [3] Intratendinous glutamate levels and eccentric training in chronic Achilles tendinosis: a prospective study using microdialysis technique
    Alfredson, H
    Lorentzon, R
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (03) : 196 - 199
  • [4] Advanced bioreactor with controlled application of multi-dimensional strain for tissue engineering
    Altman, GH
    Lu, HH
    Horan, RL
    Calabro, T
    Ryder, D
    Kaplan, DL
    Stark, P
    Martin, I
    Richmond, JC
    Vunjak-Novakovic, G
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (06): : 742 - 749
  • [5] Mechanical conditioning of cell-seeded small intestine submucosa: A potential tissue-engineering strategy for tendon repair
    Androjna, Caroline
    Spragg, Rebecca K.
    Derwin, Kathleen A.
    [J]. TISSUE ENGINEERING, 2007, 13 (02): : 233 - 243
  • [6] Ex vivo static tensile loading inhibits MMP-1 expression in rat tall tendon cells through a cytoskeletally based mechanotransduction mechanism
    Arnoczky, SP
    Tian, T
    Lavagnino, M
    Gardner, K
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 328 - 333
  • [7] Loss of homeostatic strain alters mechanostat "set point" of tendon cells in vitro
    Arnoczky, Steven P.
    Lavagnino, Michael
    Egerbacher, Monika
    Caballero, Oscar
    Gardner, Keri
    Shender, Marisa A.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (07) : 1583 - 1591
  • [8] Evaluation of gene expression through qRT-PCR in cyclically loaded tendons: an in vivo model
    Asundi, Krishna R.
    King, Karen B.
    Rempel, David M.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 102 (03) : 265 - 270
  • [9] Mechanical and physicochemical regulation of the action of insulin-like growth factor-I on articular cartilage
    Bonassar, LJ
    Grodzinsky, AJ
    Srinivasan, A
    Davila, SG
    Trippel, SB
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2000, 379 (01) : 57 - 63
  • [10] Revision anterior cruciate ligament surgery
    Brown, CH
    Carson, EW
    [J]. CLINICS IN SPORTS MEDICINE, 1999, 18 (01) : 109 - +