Non-restarting cumulative sum charts and control of the false discovery rate

被引:25
|
作者
Gandy, Axel [1 ]
Lau, F. Din-Houn [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Math, London SW7 2AZ, England
关键词
Cumulative sum chart; cusum; False discovery rate; Monitoring; Multiple data streams; SCHEMES; CUSUM;
D O I
10.1093/biomet/ass066
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cumulative sum or cusum charts are typically used to detect a change in the distribution of a sequence of observations, e.g., shifts in the mean. Usually, after signalling, the chart is restarted by setting it to some value below the signalling threshold. We propose a non-restarting cusum chart which is able to detect periods during which the stream is out of control. Further, we advocate an upper boundary to prevent the cusum chart rising too high, which helps to detect a change back into control. We present an algorithm to control the false discovery rate when considering cusum charts based on multiple streams of data. We consider two definitions of a false discovery: signalling out-of-control when the observations have been in control since the start and signalling out-of-control when the observations have been in control since the last time the chart was at zero. We prove that the false discovery rate is controlled under both these definitions simultaneously. Simulations reveal the difference in false discovery rate control when using these and other desirable definitions of a false discovery.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [41] Restoring coverage to the Bayesian false discovery rate control procedure
    Gold, David L.
    KNOWLEDGE AND INFORMATION SYSTEMS, 2012, 33 (02) : 401 - 417
  • [42] CONDITIONAL CALIBRATION FOR FALSE DISCOVERY RATE CONTROL UNDER DEPENDENCE
    Fithian, William
    Lei, Lihua
    ANNALS OF STATISTICS, 2022, 50 (06) : 3091 - 3118
  • [43] More powerful control of the false discovery rate under dependence
    Farcomeni A.
    Statistical Methods and Applications, 2006, 15 (1) : 43 - 73
  • [44] Multivariate Process Control Chart for Controlling the False Discovery Rate
    Park, Jang-Ho
    Jun, Chi-Hyuck
    INDUSTRIAL ENGINEERING AND MANAGEMENT SYSTEMS, 2012, 11 (04): : 385 - 389
  • [45] Nonparametric false discovery rate control for identifying simultaneous signals
    Zhao, Sihai Dave
    Nguyen, Yet Tien
    ELECTRONIC JOURNAL OF STATISTICS, 2020, 14 (01): : 110 - 142
  • [46] Some results on the control of the false discovery rate under dependence
    Farcomeni, Alessio
    SCANDINAVIAN JOURNAL OF STATISTICS, 2007, 34 (02) : 275 - 297
  • [47] Choosing the lesser evil: Trade-off between false discovery rate and non-discovery rate
    Craiu, Radu V.
    Sun, Lei
    STATISTICA SINICA, 2008, 18 (03) : 861 - 879
  • [48] Testing over a continuum of null hypotheses with False Discovery Rate control
    Blanchard, Gilles
    Delattre, Sylvain
    Roquain, Etienne
    BERNOULLI, 2014, 20 (01) : 304 - 333
  • [49] False Discovery Rate Control in Cancer Biomarker Selection Using Knockoffs
    Shen, Arlina
    Fu, Han
    He, Kevin
    Jiang, Hui
    CANCERS, 2019, 11 (06):
  • [50] Local structure learning of chain graphs with the false discovery rate control
    Wang, Jingyun
    Liu, Sanyang
    Zhu, Mingmin
    ARTIFICIAL INTELLIGENCE REVIEW, 2019, 52 (01) : 293 - 321