All-air system and radiant floor for heating and cooling in residential buildings: A simulation-based analysis

被引:6
作者
Alessio, Giulia [1 ]
Emmi, Giuseppe [1 ]
De Carli, Michele [1 ]
Zarrella, Angelo [1 ]
机构
[1] Univ Padua, Dept Ind Engn, Padua, Italy
关键词
THERMAL COMFORT; ENERGY-CONSUMPTION; PERFORMANCE; MODEL;
D O I
10.1080/23744731.2020.1795515
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ventilation systems are necessary to ensure a good indoor air quality, especially in buildings characterized by high energy performance. An all-air system could be more flexible than radiant systems that need to be combined with other systems to provide fresh air and control latent loads. In this work, a multi-zone all-air system has been compared with a radiant floor integrated with mechanical controlled ventilation and an isothermal dehumidifier. All the systems have been modeled in TRNSYS considering a residential building and three different locations (Helsinki, Milan and Rome). The comparison has been performed in terms of both indoor conditions and energy consumption. The results outline that the two systems are able to maintain the desired indoor conditions. For the energy consumption, an air-to-water heat pump and all the auxiliaries have been considered. Under the same indoor conditions, in heating the electrical energy consumption of the all-air system is lower than that of the radiant floor (-19% in Helsinki, -32% in Milan and -74% in Rome); also in cooling the electrical energy consumed by the all-air system is lower in Milan and Rome (-14% and -29% respectively), whereas in Helsinki the difference is less than 5%.
引用
收藏
页码:1397 / 1411
页数:15
相关论文
共 27 条
[1]  
Agenzia Nazionale Efficienza Energetica (ENEA), 2018, RAPP ANN EFF EN 2018
[2]   Efficiency in Heating Operation of Low-Temperature Radiant Systems Working under Dynamic Conditions in Different Kinds of Buildings [J].
Alessio, Giulia ;
De Carli, Michele ;
Zarrella, Angelo ;
Di Bella, Antonino .
APPLIED SCIENCES-BASEL, 2018, 8 (12)
[3]  
[Anonymous], 2012, TRNSYS 17 REF MAN
[4]  
[Anonymous], 2017, ENERGY TECHNOLOGY PE
[5]  
ASHRAE, 2001, INT WEATH EN CALC WE
[6]  
CEN, 2019, 16798 CEN
[7]   DIGITHON: A numerical model for the thermal balance of rooms equipped with radiant systems [J].
De Carli, Michele ;
Scarpa, Massimiliano ;
Tomasi, Roberta ;
Zarrella, Angelo .
BUILDING AND ENVIRONMENT, 2012, 57 :126-144
[8]  
European Committee for Standardization (CEN), 2018, 14511 CEN
[9]   Numerical comparison between energy and comfort performances of radiant heating and cooling systems versus air systems [J].
Fabrizio, Enrico ;
Corgnati, Stefano P. ;
Causone, Francesco ;
Filippi, Marco .
HVAC&R RESEARCH, 2012, 18 (04) :692-708
[10]   Thermal comfort and energy consumption of the radiant ceiling panel system. Comparison with the conventional all-air system [J].
Imanari, T ;
Omori, T ;
Bogaki, K .
ENERGY AND BUILDINGS, 1999, 30 (02) :167-175