Detection of Cyanuric Acid and Melamine in Infant Formula Powders by Mid-FTIR Spectroscopy and Multivariate Analysis

被引:10
作者
Garcia-Miguel, Edwin [1 ]
Gabriela Meza-Marquez, Ofelia [2 ]
Osorio-Revilla, Guillermo [2 ]
Iker Tellez-Medina, Dario [2 ]
Jimenez-Martinez, Cristian [2 ]
Cornejo-Mazon, Maribel [1 ]
Maylet Hernandez-Martinez, Diana [1 ]
Gallardo-Velazquez, Tzayhri [1 ]
机构
[1] Escuela Nacl Ciencias Biol, Inst Politecn Nacl, Dept Biofis, Prolongac Carpio & Plan Ayala S-N, Mexico City 11340, DF, Mexico
[2] Escuela Nacl Ciencias Biol, Inst Politecn Nacl, Dept Ingn Bioquim, Av Wilfrido Massieu S-N, Mexico City 07738, DF, Mexico
关键词
TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; MIDINFRARED SPECTROSCOPY; INFRARED-SPECTROSCOPY; RAPID-DETERMINATION; MILK POWDER; QUANTIFICATION; ADULTERATION; VALIDATION;
D O I
10.1155/2018/7926768
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Chemometric methods using mid-FTIR spectroscopy were developed in order to reduce the time of study of melamine and cyanuric acid in infant formulas. Chemometric models were constructed using the algorithms Partial Least Squares (PLS1, PLS2) and Principal Component Regression (PCR) in order to correlate the IR signal with the levels of melamine or cyanuric acid in the infant formula samples. Results showed that the best correlations were obtained using PLS1 (R2: 0.9998, SEC: 0.0793, and SEP: 0.5545 for melamine and R2: 0.9997, SEC: 0.1074, and SEP: 0.5021 for cyanuric acid). Also, the SIMCA model was studied to distinguish between adulterated formulas and nonadulterated samples, giving optimum discrimination and good interclass distances between samples. Results showed that chemometric models demonstrated a good predictive ability of melamine and cyanuric acid concentrations in infant formulas, showing that this is a rapid and accurate technique to be used in the identification and quantification of these adulterants in infant formulas.
引用
收藏
页数:7
相关论文
共 22 条
[1]  
Beebe K.R., 1998, CHEMOMETRICS PRACTIC
[2]   Use of micellar mobile phases for the chromatographic determination of melamine in dietetic supplements [J].
Beltran-Martinavarro, Beatriz ;
Peris-Vicente, Juan ;
Marco-Peiro, Sergio ;
Esteve-Romero, Josep ;
Rambla-Alegre, Maria ;
Carda-Broch, Samuel .
ANALYST, 2012, 137 (01) :269-274
[3]   Development and analytical validation of a screening method for simultaneous detection of five adulterants in raw milk using mid-infrared spectroscopy and PLS-DA [J].
Botelho, Bruno G. ;
Reis, Nadia ;
Oliveira, Leandro S. ;
Sena, Marcelo M. .
FOOD CHEMISTRY, 2015, 181 :31-37
[4]   Rapid determination of melamine in soil and strawberry by liquid chromatography-tandem mass spectrometry [J].
Ge, Jing ;
Zhao, Liu Wei ;
Liu, CongYun ;
Jiang, Shuren ;
Lee, Philip W. ;
Lie, Fengmao .
FOOD CONTROL, 2011, 22 (10) :1629-1633
[5]   Midinfrared spectroscopy for juice authentication - Rapid differentiation of commercial juices [J].
He, Jian ;
Rodriguez-Saona, Luis E. ;
Giusti, M. Monica .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (11) :4443-4452
[6]   Identification of additive components in powdered milk by NIR imaging methods [J].
Huang, Yue ;
Min, Shungeng ;
Duan, Jia ;
Wu, Lijun ;
Li, Qianqian .
FOOD CHEMISTRY, 2014, 145 :278-283
[7]   Quick determination of melamine in infant powder and liquid milk by Fourier transform infrared spectroscopy [J].
Jawaid, Sana ;
Talpur, Farah N. ;
Afridi, Hassan Imran ;
Nizamani, Shafi M. ;
Khaskheli, Abid A. ;
Naz, Saba .
ANALYTICAL METHODS, 2014, 6 (14) :5269-5273
[8]  
Kim B, 2008, J AOAC INT, V91, P408
[9]   An enzyme linked immunosorbent assay for the determination of cyromazine and melamine residues in animal muscle tissues [J].
Liu, Juxiang ;
Zhong, Yongben ;
Liu, Jing ;
Zhang, Huicai ;
Xi, Jianzhong ;
Wang, Jianping .
FOOD CONTROL, 2010, 21 (11) :1482-1487
[10]   Rapid detection of melamine in milk powder by near infrared spectroscopy [J].
Lu, Chenghui ;
Xiang, Bingren ;
Hao, Gang ;
Xu, Jianping ;
Wang, Zhengwu ;
Chen, Changyun .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2009, 17 (02) :59-67